-
Je něco špatně v tomto záznamu ?
Patient-Specific Biomechanical Modeling for Guidance During Minimally-Invasive Hepatic Surgery
R. Plantefève, I. Peterlik, N. Haouchine, S. Cotin,
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články
NLK
ProQuest Central
od 1997-01-01 do Před 1 rokem
Medline Complete (EBSCOhost)
od 2010-01-01 do Před 1 rokem
Health & Medicine (ProQuest)
od 1997-01-01 do Před 1 rokem
- MeSH
- biologické modely * MeSH
- individualizovaná medicína metody MeSH
- játra chirurgie MeSH
- lidé MeSH
- miniinvazivní chirurgické výkony metody MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
During the minimally-invasive liver surgery, only the partial surface view of the liver is usually provided to the surgeon via the laparoscopic camera. Therefore, it is necessary to estimate the actual position of the internal structures such as tumors and vessels from the pre-operative images. Nevertheless, such task can be highly challenging since during the intervention, the abdominal organs undergo important deformations due to the pneumoperitoneum, respiratory and cardiac motion and the interaction with the surgical tools. Therefore, a reliable automatic system for intra-operative guidance requires fast and reliable registration of the pre- and intra-operative data. In this paper we present a complete pipeline for the registration of pre-operative patient-specific image data to the sparse and incomplete intra-operative data. While the intra-operative data is represented by a point cloud extracted from the stereo-endoscopic images, the pre-operative data is used to reconstruct a biomechanical model which is necessary for accurate estimation of the position of the internal structures, considering the actual deformations. This model takes into account the patient-specific liver anatomy composed of parenchyma, vascularization and capsule, and is enriched with anatomical boundary conditions transferred from an atlas. The registration process employs the iterative closest point technique together with a penalty-based method. We perform a quantitative assessment based on the evaluation of the target registration error on synthetic data as well as a qualitative assessment on real patient data. We demonstrate that the proposed registration method provides good results in terms of both accuracy and robustness w.r.t. the quality of the intra-operative data.
Altran and Inria Strasbourg France
Institute of Computer Science Masaryk University Brno Czech Republic
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16028285
- 003
- CZ-PrNML
- 005
- 20161018100325.0
- 007
- ta
- 008
- 161005s2016 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1007/s10439-015-1419-z $2 doi
- 024 7_
- $a 10.1007/s10439-015-1419-z $2 doi
- 035 __
- $a (PubMed)26297341
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Plantefève, Rosalie $u Altran and Inria (Mimesis Team), Strasbourg, France. rosalie.plantefeve@inria.fr.
- 245 10
- $a Patient-Specific Biomechanical Modeling for Guidance During Minimally-Invasive Hepatic Surgery / $c R. Plantefève, I. Peterlik, N. Haouchine, S. Cotin,
- 520 9_
- $a During the minimally-invasive liver surgery, only the partial surface view of the liver is usually provided to the surgeon via the laparoscopic camera. Therefore, it is necessary to estimate the actual position of the internal structures such as tumors and vessels from the pre-operative images. Nevertheless, such task can be highly challenging since during the intervention, the abdominal organs undergo important deformations due to the pneumoperitoneum, respiratory and cardiac motion and the interaction with the surgical tools. Therefore, a reliable automatic system for intra-operative guidance requires fast and reliable registration of the pre- and intra-operative data. In this paper we present a complete pipeline for the registration of pre-operative patient-specific image data to the sparse and incomplete intra-operative data. While the intra-operative data is represented by a point cloud extracted from the stereo-endoscopic images, the pre-operative data is used to reconstruct a biomechanical model which is necessary for accurate estimation of the position of the internal structures, considering the actual deformations. This model takes into account the patient-specific liver anatomy composed of parenchyma, vascularization and capsule, and is enriched with anatomical boundary conditions transferred from an atlas. The registration process employs the iterative closest point technique together with a penalty-based method. We perform a quantitative assessment based on the evaluation of the target registration error on synthetic data as well as a qualitative assessment on real patient data. We demonstrate that the proposed registration method provides good results in terms of both accuracy and robustness w.r.t. the quality of the intra-operative data.
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a játra $x chirurgie $7 D008099
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a miniinvazivní chirurgické výkony $x metody $7 D019060
- 650 12
- $a biologické modely $7 D008954
- 650 _2
- $a individualizovaná medicína $x metody $7 D057285
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Peterlik, Igor $u Institute of Computer Science, Masaryk University, Brno, Czech Republic.
- 700 1_
- $a Haouchine, Nazim $u Inria (Mimesis Team), Strasbourg, France.
- 700 1_
- $a Cotin, Stéphane $u Inria (Mimesis Team), Strasbourg, France.
- 773 0_
- $w MED00149876 $t Annals of biomedical engineering $x 1573-9686 $g Roč. 44, č. 1 (2016), s. 139-53
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/26297341 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20161005 $b ABA008
- 991 __
- $a 20161018100730 $b ABA008
- 999 __
- $a ok $b bmc $g 1166599 $s 952915
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2016 $b 44 $c 1 $d 139-53 $e 20150822 $i 1573-9686 $m Annals of biomedical engineering $n Ann. biomed. eng. $x MED00149876
- LZP __
- $a Pubmed-20161005