A fully automated and fast method using direct sample injection combined with fused-core column on-line SPE-HPLC for determination of ochratoxin A and citrinin in lager beers

I. Lhotská, D. Šatínský, L. Havlíková, P. Solich,

. 2016 ; 408 (12) : 3319-29. [pub] 20160318

Language English Country Germany

Document type Journal Article, Research Support, Non-U.S. Gov't

E-resources Online Full text

NLK ProQuest Central from 2011-01-01 to 1 year ago
Medline Complete (EBSCOhost) from 2003-01-01 to 1 year ago
Health & Medicine (ProQuest) from 2011-01-01 to 1 year ago

A new fast and sensitive method based on on-line solid-phase extraction on a fused-core precolumn coupled to liquid chromatography with fluorescence detection has been developed for ochratoxin A (OTA) and citrinin (CIT) determination in lager beer samples. Direct injection of 100 μL filtered beer samples into an on-line SPE-HPLC system enabled fast and effective sample extraction including separation in less than 6 min. Preconcentration of OTA and CIT from beer samples was performed on an Ascentis Express RP C18 guard column (5 × 4.6 mm), particle size 2.7 μm, with a mobile phase of methanol/0.5% aqueous acetic acid pH 2.8 (30:70, v/v) at a flow rate of 2.0 mL min(-1). The flow switch from extraction column to analytical column in back-flush mode was set at 2.0 min and the separation was performed on the fused-core column Ascentis Express Phenyl-Hexyl (100 × 4.6 mm), particle size 2.7 μm, with a mobile phase acetonitrile/0.5% aqueous acetic acid pH 2.8 in a gradient elution at a flow rate of 1.0 mL min(-1) and temperature of 50 °C. Fluorescence excitation/emission detection wavelengths were set at 335/497 nm. The accuracy of the method, defined as the mean recoveries of OTA and CIT from light and dark beer samples, was in the range 98.3-102.1%. The method showed high sensitivity owing to on-line preconcentration; LOQ values were found to be 10 and 20 ng L(-1) for OTA and CIT, respectively. The found values of OTA and CIT in all tested light, dark and wheat beer samples were significantly below the maximum tolerable limits (3.0 μg kg(-1) for OTA and 2000 μg kg(-1) for CIT) set by the European Union.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc17000330
003      
CZ-PrNML
005      
20170113102452.0
007      
ta
008      
170103s2016 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1007/s00216-016-9402-6 $2 doi
024    7_
$a 10.1007/s00216-016-9402-6 $2 doi
035    __
$a (PubMed)26993307
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Lhotská, Ivona $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského 1203, Hradec Králové, 500 05, Czech Republic.
245    12
$a A fully automated and fast method using direct sample injection combined with fused-core column on-line SPE-HPLC for determination of ochratoxin A and citrinin in lager beers / $c I. Lhotská, D. Šatínský, L. Havlíková, P. Solich,
520    9_
$a A new fast and sensitive method based on on-line solid-phase extraction on a fused-core precolumn coupled to liquid chromatography with fluorescence detection has been developed for ochratoxin A (OTA) and citrinin (CIT) determination in lager beer samples. Direct injection of 100 μL filtered beer samples into an on-line SPE-HPLC system enabled fast and effective sample extraction including separation in less than 6 min. Preconcentration of OTA and CIT from beer samples was performed on an Ascentis Express RP C18 guard column (5 × 4.6 mm), particle size 2.7 μm, with a mobile phase of methanol/0.5% aqueous acetic acid pH 2.8 (30:70, v/v) at a flow rate of 2.0 mL min(-1). The flow switch from extraction column to analytical column in back-flush mode was set at 2.0 min and the separation was performed on the fused-core column Ascentis Express Phenyl-Hexyl (100 × 4.6 mm), particle size 2.7 μm, with a mobile phase acetonitrile/0.5% aqueous acetic acid pH 2.8 in a gradient elution at a flow rate of 1.0 mL min(-1) and temperature of 50 °C. Fluorescence excitation/emission detection wavelengths were set at 335/497 nm. The accuracy of the method, defined as the mean recoveries of OTA and CIT from light and dark beer samples, was in the range 98.3-102.1%. The method showed high sensitivity owing to on-line preconcentration; LOQ values were found to be 10 and 20 ng L(-1) for OTA and CIT, respectively. The found values of OTA and CIT in all tested light, dark and wheat beer samples were significantly below the maximum tolerable limits (3.0 μg kg(-1) for OTA and 2000 μg kg(-1) for CIT) set by the European Union.
650    12
$a automatizace $7 D001331
650    _2
$a pivo $x analýza $7 D001515
650    _2
$a vysokoúčinná kapalinová chromatografie $x metody $7 D002851
650    _2
$a citrinin $x analýza $7 D002953
650    _2
$a ochratoxiny $x analýza $7 D009793
650    _2
$a extrakce na pevné fázi $x metody $7 D052616
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Šatínský, Dalibor $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského 1203, Hradec Králové, 500 05, Czech Republic. satinsky@faf.cuni.cz.
700    1_
$a Havlíková, Lucie $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského 1203, Hradec Králové, 500 05, Czech Republic.
700    1_
$a Solich, Petr $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského 1203, Hradec Králové, 500 05, Czech Republic.
773    0_
$w MED00006638 $t Analytical and bioanalytical chemistry $x 1618-2650 $g Roč. 408, č. 12 (2016), s. 3319-29
856    41
$u https://pubmed.ncbi.nlm.nih.gov/26993307 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20170103 $b ABA008
991    __
$a 20170113102552 $b ABA008
999    __
$a ok $b bmc $g 1179470 $s 960897
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2016 $b 408 $c 12 $d 3319-29 $e 20160318 $i 1618-2650 $m Analytical and bioanalytical chemistry $n Anal Bioanal Chem $x MED00006638
LZP    __
$a Pubmed-20170103

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...