Je něco špatně v tomto záznamu ?
Development of MEPS-UHPLC-MS/MS multistatin methods for clinical analysis
H. Vlčková, P. Svoboda, O. Novák, P. Solich, L. Nováková,
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu časopisecké články, práce podpořená grantem, přehledy
PubMed
26858167
DOI
10.4155/bio.15.245
Knihovny.cz E-zdroje
- MeSH
- biochemická analýza krve metody MeSH
- chemická precipitace MeSH
- lidé MeSH
- limita detekce MeSH
- mikroextrakce na pevné fázi metody MeSH
- reprodukovatelnost výsledků MeSH
- statiny krev chemie izolace a purifikace MeSH
- tandemová hmotnostní spektrometrie metody MeSH
- vysokoúčinná kapalinová chromatografie metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- přehledy MeSH
BACKGROUND: Statins are the microsomal 3-hydroxy-3methylglutaryl-coenzyme A reductase inhibitors used for the treatment of hypercholesterolemia. Some recent studies revealed also the extra-lipid effects and anticancer activities. Due to the wide incidence of cancer diseases, the number of studies dealing with anticancer statin activities has grown in recent years. Development of one universal multistatin method will be a very convenient way of providing practical and economical multiple statin analysis. Results/methodology: Fast and sensitive methods for determination of seven clinically relevant statins, their interconversion products and metabolites (17 analytes in total) in biological samples using microextraction by packed sorbent for sample preparation and UHPLC-MS/MS for subsequent analysis were developed and validated. Three MS platforms with different ion sources, transfer optics, collision cell technologies and scan speed parameters were compared. CONCLUSION: Significant differences among the methods were observed in terms of selectivity and sensitivity. Microextraction by packed sorbent was successful in the extraction of all 17 analytes from biological matrix.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc17000503
- 003
- CZ-PrNML
- 005
- 20170113112338.0
- 007
- ta
- 008
- 170103s2016 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.4155/bio.15.245 $2 doi
- 024 7_
- $a 10.4155/bio.15.245 $2 doi
- 035 __
- $a (PubMed)26858167
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Vlčková, Hana $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského 1203, 500 05 Hradec Králové, Czech Republic.
- 245 10
- $a Development of MEPS-UHPLC-MS/MS multistatin methods for clinical analysis / $c H. Vlčková, P. Svoboda, O. Novák, P. Solich, L. Nováková,
- 520 9_
- $a BACKGROUND: Statins are the microsomal 3-hydroxy-3methylglutaryl-coenzyme A reductase inhibitors used for the treatment of hypercholesterolemia. Some recent studies revealed also the extra-lipid effects and anticancer activities. Due to the wide incidence of cancer diseases, the number of studies dealing with anticancer statin activities has grown in recent years. Development of one universal multistatin method will be a very convenient way of providing practical and economical multiple statin analysis. Results/methodology: Fast and sensitive methods for determination of seven clinically relevant statins, their interconversion products and metabolites (17 analytes in total) in biological samples using microextraction by packed sorbent for sample preparation and UHPLC-MS/MS for subsequent analysis were developed and validated. Three MS platforms with different ion sources, transfer optics, collision cell technologies and scan speed parameters were compared. CONCLUSION: Significant differences among the methods were observed in terms of selectivity and sensitivity. Microextraction by packed sorbent was successful in the extraction of all 17 analytes from biological matrix.
- 650 _2
- $a biochemická analýza krve $x metody $7 D001774
- 650 _2
- $a chemická precipitace $7 D011232
- 650 _2
- $a vysokoúčinná kapalinová chromatografie $x metody $7 D002851
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a statiny $x krev $x chemie $x izolace a purifikace $7 D019161
- 650 _2
- $a limita detekce $7 D057230
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a mikroextrakce na pevné fázi $x metody $7 D052617
- 650 _2
- $a tandemová hmotnostní spektrometrie $x metody $7 D053719
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 655 _2
- $a přehledy $7 D016454
- 700 1_
- $a Svoboda, Pavel $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského 1203, 500 05 Hradec Králové, Czech Republic.
- 700 1_
- $a Novák, Ondřej $u Laboratory of Growth Regulators, Centre of the Region Haná for Biotechnological & Agricultural Research, Faculty of Science, Palacký University & Institute of Experimental Botany AS CR, Šlechtitelů 27, 783 71 Olomouc, Czech Republic.
- 700 1_
- $a Solich, Petr $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského 1203, 500 05 Hradec Králové, Czech Republic.
- 700 1_
- $a Nováková, Lucie $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského 1203, 500 05 Hradec Králové, Czech Republic.
- 773 0_
- $w MED00184533 $t Bioanalysis $x 1757-6199 $g Roč. 8, č. 4 (2016), s. 333-49
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/26858167 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20170103 $b ABA008
- 991 __
- $a 20170113112439 $b ABA008
- 999 __
- $a ok $b bmc $g 1179643 $s 961070
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2016 $b 8 $c 4 $d 333-49 $e 20160209 $i 1757-6199 $m Bioanalysis $n Bioanal. $x MED00184533
- LZP __
- $a Pubmed-20170103