Je něco špatně v tomto záznamu ?
Determination of selected synthetic cannabinoids and their metabolites by micellar electrokinetic chromatography--mass spectrometry employing perfluoroheptanoic acid-based micellar phase
M. Švidrnoch, A. Přibylka, V. Maier,
Jazyk angličtina Země Nizozemsko
Typ dokumentu časopisecké články, práce podpořená grantem
- MeSH
- chromatografie kapalinová metody MeSH
- chromatografie micelární elektrokinetická kapilární metody MeSH
- extrakce kapalina-kapalina metody MeSH
- fluorokarbony chemie MeSH
- kanabinoidy krev moč MeSH
- kyseliny heptylové chemie MeSH
- lidé MeSH
- limita detekce MeSH
- micely MeSH
- tandemová hmotnostní spektrometrie metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Perfluoroheptanoic acid was employed as a volatile micellar phase in background electrolyte for micellar electrokinetic chromatography-tandem mass spectrometry separation and determination of 15 selected naphthoyl- and phenylacetylindole- synthetic cannabinoids and main metabolites derived from JWH-018, JWH-019, JWH-073, JWH-200 and JWH-250. The influence of concentration of perfluoroheptanoic acid in background electrolytes on the separation was studied as well as the influence of perfluoroheptanoic acid on mass spectrometry detection. The background electrolyte consisted of 75 mM perfluoroheptanoic acid, 150 mM ammonium hydroxide pH 9.2 with 10% (v/v) propane-2-ol allowed micellar electrokinetic chromatography separation together with mass spectrometry identification of the studied parent synthetic cannabinoids and their metabolites. The limits of detection of studied synthetic cannabinoids and metabolites were in the range from 0.9 ng/mL for JWH-073 to 3.0 ng/mL for JWH-200 employing liquid-liquid extraction. The developed method was applied on the separation and identification of studied analytes after liquid-liquid extraction of spiked urine and serum samples to demonstrate the potential of the method applicability for forensic and toxicological purposes.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc17000539
- 003
- CZ-PrNML
- 005
- 20170117122454.0
- 007
- ta
- 008
- 170103s2016 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.talanta.2015.12.078 $2 doi
- 024 7_
- $a 10.1016/j.talanta.2015.12.078 $2 doi
- 035 __
- $a (PubMed)26838444
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Švidrnoch, Martin $u Regional Centre of Advanced Technologies and Materials, Department of Analytical, Chemistry, Faculty of Science, Palacký University in Olomouc, 17. Listopadu 12, Olomouc CZ-77146, Czech Republic.
- 245 10
- $a Determination of selected synthetic cannabinoids and their metabolites by micellar electrokinetic chromatography--mass spectrometry employing perfluoroheptanoic acid-based micellar phase / $c M. Švidrnoch, A. Přibylka, V. Maier,
- 520 9_
- $a Perfluoroheptanoic acid was employed as a volatile micellar phase in background electrolyte for micellar electrokinetic chromatography-tandem mass spectrometry separation and determination of 15 selected naphthoyl- and phenylacetylindole- synthetic cannabinoids and main metabolites derived from JWH-018, JWH-019, JWH-073, JWH-200 and JWH-250. The influence of concentration of perfluoroheptanoic acid in background electrolytes on the separation was studied as well as the influence of perfluoroheptanoic acid on mass spectrometry detection. The background electrolyte consisted of 75 mM perfluoroheptanoic acid, 150 mM ammonium hydroxide pH 9.2 with 10% (v/v) propane-2-ol allowed micellar electrokinetic chromatography separation together with mass spectrometry identification of the studied parent synthetic cannabinoids and their metabolites. The limits of detection of studied synthetic cannabinoids and metabolites were in the range from 0.9 ng/mL for JWH-073 to 3.0 ng/mL for JWH-200 employing liquid-liquid extraction. The developed method was applied on the separation and identification of studied analytes after liquid-liquid extraction of spiked urine and serum samples to demonstrate the potential of the method applicability for forensic and toxicological purposes.
- 650 _2
- $a kanabinoidy $x krev $x moč $7 D002186
- 650 _2
- $a chromatografie kapalinová $x metody $7 D002853
- 650 _2
- $a chromatografie micelární elektrokinetická kapilární $x metody $7 D020374
- 650 _2
- $a fluorokarbony $x chemie $7 D005466
- 650 _2
- $a kyseliny heptylové $x chemie $7 D006538
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a limita detekce $7 D057230
- 650 _2
- $a extrakce kapalina-kapalina $x metody $7 D059625
- 650 _2
- $a micely $7 D008823
- 650 _2
- $a tandemová hmotnostní spektrometrie $x metody $7 D053719
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Přibylka, Adam $u Regional Centre of Advanced Technologies and Materials, Department of Analytical, Chemistry, Faculty of Science, Palacký University in Olomouc, 17. Listopadu 12, Olomouc CZ-77146, Czech Republic.
- 700 1_
- $a Maier, Vítězslav $u Regional Centre of Advanced Technologies and Materials, Department of Analytical, Chemistry, Faculty of Science, Palacký University in Olomouc, 17. Listopadu 12, Olomouc CZ-77146, Czech Republic. Electronic address: vitezslav.maier@upol.cz.
- 773 0_
- $w MED00004484 $t Talanta $x 1873-3573 $g Roč. 150, č. - (2016), s. 568-76
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/26838444 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20170103 $b ABA008
- 991 __
- $a 20170117122600 $b ABA008
- 999 __
- $a ok $b bmc $g 1179679 $s 961106
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2016 $b 150 $c - $d 568-76 $e 20151231 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
- LZP __
- $a Pubmed-20170103