• Something wrong with this record ?

Determination of selected synthetic cannabinoids and their metabolites by micellar electrokinetic chromatography--mass spectrometry employing perfluoroheptanoic acid-based micellar phase

M. Švidrnoch, A. Přibylka, V. Maier,

. 2016 ; 150 (-) : 568-76. [pub] 20151231

Language English Country Netherlands

Document type Journal Article, Research Support, Non-U.S. Gov't

Perfluoroheptanoic acid was employed as a volatile micellar phase in background electrolyte for micellar electrokinetic chromatography-tandem mass spectrometry separation and determination of 15 selected naphthoyl- and phenylacetylindole- synthetic cannabinoids and main metabolites derived from JWH-018, JWH-019, JWH-073, JWH-200 and JWH-250. The influence of concentration of perfluoroheptanoic acid in background electrolytes on the separation was studied as well as the influence of perfluoroheptanoic acid on mass spectrometry detection. The background electrolyte consisted of 75 mM perfluoroheptanoic acid, 150 mM ammonium hydroxide pH 9.2 with 10% (v/v) propane-2-ol allowed micellar electrokinetic chromatography separation together with mass spectrometry identification of the studied parent synthetic cannabinoids and their metabolites. The limits of detection of studied synthetic cannabinoids and metabolites were in the range from 0.9 ng/mL for JWH-073 to 3.0 ng/mL for JWH-200 employing liquid-liquid extraction. The developed method was applied on the separation and identification of studied analytes after liquid-liquid extraction of spiked urine and serum samples to demonstrate the potential of the method applicability for forensic and toxicological purposes.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc17000539
003      
CZ-PrNML
005      
20170117122454.0
007      
ta
008      
170103s2016 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.talanta.2015.12.078 $2 doi
024    7_
$a 10.1016/j.talanta.2015.12.078 $2 doi
035    __
$a (PubMed)26838444
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Švidrnoch, Martin $u Regional Centre of Advanced Technologies and Materials, Department of Analytical, Chemistry, Faculty of Science, Palacký University in Olomouc, 17. Listopadu 12, Olomouc CZ-77146, Czech Republic.
245    10
$a Determination of selected synthetic cannabinoids and their metabolites by micellar electrokinetic chromatography--mass spectrometry employing perfluoroheptanoic acid-based micellar phase / $c M. Švidrnoch, A. Přibylka, V. Maier,
520    9_
$a Perfluoroheptanoic acid was employed as a volatile micellar phase in background electrolyte for micellar electrokinetic chromatography-tandem mass spectrometry separation and determination of 15 selected naphthoyl- and phenylacetylindole- synthetic cannabinoids and main metabolites derived from JWH-018, JWH-019, JWH-073, JWH-200 and JWH-250. The influence of concentration of perfluoroheptanoic acid in background electrolytes on the separation was studied as well as the influence of perfluoroheptanoic acid on mass spectrometry detection. The background electrolyte consisted of 75 mM perfluoroheptanoic acid, 150 mM ammonium hydroxide pH 9.2 with 10% (v/v) propane-2-ol allowed micellar electrokinetic chromatography separation together with mass spectrometry identification of the studied parent synthetic cannabinoids and their metabolites. The limits of detection of studied synthetic cannabinoids and metabolites were in the range from 0.9 ng/mL for JWH-073 to 3.0 ng/mL for JWH-200 employing liquid-liquid extraction. The developed method was applied on the separation and identification of studied analytes after liquid-liquid extraction of spiked urine and serum samples to demonstrate the potential of the method applicability for forensic and toxicological purposes.
650    _2
$a kanabinoidy $x krev $x moč $7 D002186
650    _2
$a chromatografie kapalinová $x metody $7 D002853
650    _2
$a chromatografie micelární elektrokinetická kapilární $x metody $7 D020374
650    _2
$a fluorokarbony $x chemie $7 D005466
650    _2
$a kyseliny heptylové $x chemie $7 D006538
650    _2
$a lidé $7 D006801
650    _2
$a limita detekce $7 D057230
650    _2
$a extrakce kapalina-kapalina $x metody $7 D059625
650    _2
$a micely $7 D008823
650    _2
$a tandemová hmotnostní spektrometrie $x metody $7 D053719
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Přibylka, Adam $u Regional Centre of Advanced Technologies and Materials, Department of Analytical, Chemistry, Faculty of Science, Palacký University in Olomouc, 17. Listopadu 12, Olomouc CZ-77146, Czech Republic.
700    1_
$a Maier, Vítězslav $u Regional Centre of Advanced Technologies and Materials, Department of Analytical, Chemistry, Faculty of Science, Palacký University in Olomouc, 17. Listopadu 12, Olomouc CZ-77146, Czech Republic. Electronic address: vitezslav.maier@upol.cz.
773    0_
$w MED00004484 $t Talanta $x 1873-3573 $g Roč. 150, č. - (2016), s. 568-76
856    41
$u https://pubmed.ncbi.nlm.nih.gov/26838444 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20170103 $b ABA008
991    __
$a 20170117122600 $b ABA008
999    __
$a ok $b bmc $g 1179679 $s 961106
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2016 $b 150 $c - $d 568-76 $e 20151231 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
LZP    __
$a Pubmed-20170103

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...