• Je něco špatně v tomto záznamu ?

A study of retention characteristics and quality control of nutraceuticals containing resveratrol and polydatin using fused-core column chromatography

J. Fibigr, D. Šatínský, P. Solich,

. 2016 ; 120 (-) : 112-9. [pub] 20151215

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc17000708

A new high-performance liquid chromatography method using fused-core column for fast separation of resveratrol and polydatin has been developed and used for quality control of nutraceuticals with resveratrol and polydatin content. Retention characteristics (log k) were studied under different conditions on C-18, RP-Amide C-18, Phenyl-hexyl, Pentafluorophenyl (F5) and Cyano stationary phases for both compounds. The effect of the volume fraction of acetonitrile on a retention factors log k of resveratrol and polydatin were evaluated. The optimal separation conditions for resveratrol, polydatin and internal standard p-nitrophenol were found on the fused-core column Ascentis Express ES-Cyano (100×3.0mm), particle size 2.7μm, with mobile phase acetonitrile/water solution with 0.5% acetic acid pH 3 (20:80, v/v) at a flow rate of 1.0mL/min and at 60°C. The detection wavelength was set at 305nm. Under the optimal chromatographic conditions, good linearity with regression coefficients in the range (r=0.9992-0.9998; n=10) for both compounds was achieved. Commercial samples of nutraceuticals were extracted with methanol using ultrasound bath for 15min. A 5μL sample volume of the filtered solution was directly injected into the HPLC system. Accuracy of the method defined as a mean recovery was in the range 83.2-107.3% for both nutraceuticals. The intraday method precision was found satisfactory and relative standard deviations of sample analysis were in the range 0.8-4.7%. The developed method has shown high sample throughput during sample preparation process, modern separation approach, and short time (3min) of analysis. The results of study showed that the declared content of resveratrol and polydatin varied widely in different nutraceuticals according the producers (71.50-115.00% of declared content).

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc17000708
003      
CZ-PrNML
005      
20170119122719.0
007      
ta
008      
170103s2016 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.jpba.2015.12.014 $2 doi
024    7_
$a 10.1016/j.jpba.2015.12.014 $2 doi
035    __
$a (PubMed)26719982
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Fibigr, Jakub $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského 1203, Hradec Králové 500 05, Czech Republic.
245    12
$a A study of retention characteristics and quality control of nutraceuticals containing resveratrol and polydatin using fused-core column chromatography / $c J. Fibigr, D. Šatínský, P. Solich,
520    9_
$a A new high-performance liquid chromatography method using fused-core column for fast separation of resveratrol and polydatin has been developed and used for quality control of nutraceuticals with resveratrol and polydatin content. Retention characteristics (log k) were studied under different conditions on C-18, RP-Amide C-18, Phenyl-hexyl, Pentafluorophenyl (F5) and Cyano stationary phases for both compounds. The effect of the volume fraction of acetonitrile on a retention factors log k of resveratrol and polydatin were evaluated. The optimal separation conditions for resveratrol, polydatin and internal standard p-nitrophenol were found on the fused-core column Ascentis Express ES-Cyano (100×3.0mm), particle size 2.7μm, with mobile phase acetonitrile/water solution with 0.5% acetic acid pH 3 (20:80, v/v) at a flow rate of 1.0mL/min and at 60°C. The detection wavelength was set at 305nm. Under the optimal chromatographic conditions, good linearity with regression coefficients in the range (r=0.9992-0.9998; n=10) for both compounds was achieved. Commercial samples of nutraceuticals were extracted with methanol using ultrasound bath for 15min. A 5μL sample volume of the filtered solution was directly injected into the HPLC system. Accuracy of the method defined as a mean recovery was in the range 83.2-107.3% for both nutraceuticals. The intraday method precision was found satisfactory and relative standard deviations of sample analysis were in the range 0.8-4.7%. The developed method has shown high sample throughput during sample preparation process, modern separation approach, and short time (3min) of analysis. The results of study showed that the declared content of resveratrol and polydatin varied widely in different nutraceuticals according the producers (71.50-115.00% of declared content).
650    _2
$a acetonitrily $x chemie $7 D000097
650    _2
$a vysokoúčinná kapalinová chromatografie $x metody $7 D002851
650    _2
$a potravní doplňky $x analýza $7 D019587
650    _2
$a glukosidy $x chemie $7 D005960
650    _2
$a indikátory a reagencie $x chemie $7 D007202
650    _2
$a nitrofenoly $x chemie $7 D009596
650    _2
$a řízení kvality $7 D011786
650    _2
$a roztoky $x chemie $7 D012996
650    _2
$a stilbeny $x chemie $7 D013267
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Šatínský, Dalibor $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského 1203, Hradec Králové 500 05, Czech Republic. Electronic address: satinsky@faf.cuni.cz.
700    1_
$a Solich, Petr $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského 1203, Hradec Králové 500 05, Czech Republic.
773    0_
$w MED00002894 $t Journal of pharmaceutical and biomedical analysis $x 1873-264X $g Roč. 120, č. - (2016), s. 112-9
856    41
$u https://pubmed.ncbi.nlm.nih.gov/26719982 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20170103 $b ABA008
991    __
$a 20170119122827 $b ABA008
999    __
$a ok $b bmc $g 1179848 $s 961275
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2016 $b 120 $c - $d 112-9 $e 20151215 $i 1873-264X $m Journal of pharmaceutical and biomedical analysis $n J Pharm Biomed Anal $x MED00002894
LZP    __
$a Pubmed-20170103

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...