-
Something wrong with this record ?
Factors underlying elevated troponin I levels following pacemaker primo-implantation
T. Hnatek, M. Taborsky, M. Maly, L. Kamenik, S. Littnerova, P. Sedlon, J. Luxova, M. Fiserova, L. Pospisilova, S. Hamouzova, J. Danek, M. Zavoral
Language English Country Czech Republic
Document type Journal Article
NLK
Directory of Open Access Journals
from 2001
Free Medical Journals
from 1998
Medline Complete (EBSCOhost)
from 2007-06-01
ROAD: Directory of Open Access Scholarly Resources
from 2001
PubMed
26769435
DOI
10.5507/bp.2015.067
Knihovny.cz E-resources
- MeSH
- Biomarkers metabolism MeSH
- Prosthesis Implantation MeSH
- Electrodes, Implanted MeSH
- Pacemaker, Artificial * MeSH
- Creatine Kinase, MB Form metabolism MeSH
- Humans MeSH
- Myoglobin metabolism MeSH
- Postoperative Complications blood diagnosis MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Arrhythmias, Cardiac blood therapy MeSH
- Troponin I metabolism MeSH
- Check Tag
- Humans MeSH
- Male MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
BACKGROUND: Cardiac troponins are routinely used as markers of myocardial damage. Originally, they were only intended for use in diagnosing acute coronary syndromes; however, we now know that raised serum troponin levels are not always caused by ischemia. There are many other clinical conditions that cause damage to cardiomyocytes, leading to raised levels of troponin. However, the specificity of cardiac troponins towards the myocardium is absolute. Our work focuses on mechanical damage to the myocardium and on monitoring the factors that raise the levels of cardiospecific markers after primo-implantation of a pacemaker with an actively fixed electrode. AIMS: (i) To determine whether the use of a primo-implanted pacemaker with an electrode system with active fixation will raise troponin levels over baseline. (ii) To assess whether troponin I elevation is dependent on procedure complexity. METHODS: We enrolled 219 consecutive patients indicated for pacemaker primo-implantation; cardiospecific marker values (troponin I, CKMB, myoglobin) were determined before the implantation procedure and again at 6- and 18-h intervals after the procedure. We monitored duration of cardiac skiascopy, number of attempts to place the electrode (active penetration into the tissue) and intervention range (single-chamber versus dual-chamber pacing), and we assessed the clinical data. RESULTS: The average age of the enrolled patients was 78.2 ± 8.0 years (median age, 80 years); women constituted 45% of the group. We implanted 128 dual-chamber and 91 single-chamber devices with an average skiascopic time of 38.6 ± 22.0 s (median, 33.5 s). Troponin I serum levels increased from an initial 0.03 ± 0.07 μg/L (median, 0.01) to 0.18 ± 0.17 μg/L (median, 0.13) and 0.09 ± 0.18 μg/L (median, 0.04) at 6 and 18 h, respectively. The differences were statistically significant (P < 0.001 or P < 0.001). We confirmed a correlation between troponin increase and duration of skiascopy (P < 0.001). We also demonstrated a correlation between increased troponin I and number of attempts to place a pacemaker electrode (penetration into the tissue) at 6 h (P < 0.001) post-implantation. CONCLUSION: We detected slightly elevated troponin I levels in patients with primo-implanted pacemakers using electrodes with active fixation. We demonstrated a direct correlation between myocardial damage (number of electrode penetrations into the myocardium) and troponin I elevation, as well as between complexity (severity) of the implantation procedure (indicated by prolonged skiascopy) and raised troponin I. The described phenomenon demonstrates the loss of the diagnostic role of troponin I early after pacemaker primo-implantation in patients with concomitant chest pain.
Department of Clinical Biochemistry Military University Hospital Prague Czech Republic
Institute of Biostatistics and Analyses Masaryk University Brno Czech Republic
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc17012976
- 003
- CZ-PrNML
- 005
- 20170517081920.0
- 007
- ta
- 008
- 170413s2016 xr d f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.5507/bp.2015.067 $2 doi
- 035 __
- $a (PubMed)26769435
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Hnátek, Tomáš $u Department of Internal Medicine - Cardiology, 1st Faculty of Medicine, Charles University in Prague and Military University Hospital, Prague, Czech Republic; Department of Internal medicine I - Cardiology, Faculty of Medicine and Dentistry, Palacky University Olomouc and University Hospital Olomouc, Czech Republic $7 xx0074069
- 245 10
- $a Factors underlying elevated troponin I levels following pacemaker primo-implantation / $c T. Hnatek, M. Taborsky, M. Maly, L. Kamenik, S. Littnerova, P. Sedlon, J. Luxova, M. Fiserova, L. Pospisilova, S. Hamouzova, J. Danek, M. Zavoral
- 520 9_
- $a BACKGROUND: Cardiac troponins are routinely used as markers of myocardial damage. Originally, they were only intended for use in diagnosing acute coronary syndromes; however, we now know that raised serum troponin levels are not always caused by ischemia. There are many other clinical conditions that cause damage to cardiomyocytes, leading to raised levels of troponin. However, the specificity of cardiac troponins towards the myocardium is absolute. Our work focuses on mechanical damage to the myocardium and on monitoring the factors that raise the levels of cardiospecific markers after primo-implantation of a pacemaker with an actively fixed electrode. AIMS: (i) To determine whether the use of a primo-implanted pacemaker with an electrode system with active fixation will raise troponin levels over baseline. (ii) To assess whether troponin I elevation is dependent on procedure complexity. METHODS: We enrolled 219 consecutive patients indicated for pacemaker primo-implantation; cardiospecific marker values (troponin I, CKMB, myoglobin) were determined before the implantation procedure and again at 6- and 18-h intervals after the procedure. We monitored duration of cardiac skiascopy, number of attempts to place the electrode (active penetration into the tissue) and intervention range (single-chamber versus dual-chamber pacing), and we assessed the clinical data. RESULTS: The average age of the enrolled patients was 78.2 ± 8.0 years (median age, 80 years); women constituted 45% of the group. We implanted 128 dual-chamber and 91 single-chamber devices with an average skiascopic time of 38.6 ± 22.0 s (median, 33.5 s). Troponin I serum levels increased from an initial 0.03 ± 0.07 μg/L (median, 0.01) to 0.18 ± 0.17 μg/L (median, 0.13) and 0.09 ± 0.18 μg/L (median, 0.04) at 6 and 18 h, respectively. The differences were statistically significant (P < 0.001 or P < 0.001). We confirmed a correlation between troponin increase and duration of skiascopy (P < 0.001). We also demonstrated a correlation between increased troponin I and number of attempts to place a pacemaker electrode (penetration into the tissue) at 6 h (P < 0.001) post-implantation. CONCLUSION: We detected slightly elevated troponin I levels in patients with primo-implanted pacemakers using electrodes with active fixation. We demonstrated a direct correlation between myocardial damage (number of electrode penetrations into the myocardium) and troponin I elevation, as well as between complexity (severity) of the implantation procedure (indicated by prolonged skiascopy) and raised troponin I. The described phenomenon demonstrates the loss of the diagnostic role of troponin I early after pacemaker primo-implantation in patients with concomitant chest pain.
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a senioři nad 80 let $7 D000369
- 650 _2
- $a srdeční arytmie $x krev $x terapie $7 D001145
- 650 _2
- $a biologické markery $x metabolismus $7 D015415
- 650 _2
- $a kreatinkinasa, forma MB $x metabolismus $7 D052279
- 650 _2
- $a implantované elektrody $7 D004567
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a myoglobin $x metabolismus $7 D009211
- 650 12
- $a kardiostimulátor $7 D010138
- 650 _2
- $a pooperační komplikace $x krev $x diagnóza $7 D011183
- 650 _2
- $a implantace protézy $7 D019919
- 650 _2
- $a troponin I $x metabolismus $7 D019210
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Táborský, Miloš, $u Department of Internal medicine I - Cardiology, Faculty of Medicine and Dentistry, Palacky University Olomouc and University Hospital Olomouc, Czech Republic $d 1962- $7 jn20010310074
- 700 1_
- $a Malý, Martin, $u Department of Internal Medicine - Cardiology, 1st Faculty of Medicine, Charles University in Prague and Military University Hospital, Prague, Czech Republic $d 1966- $7 mzk2004241073
- 700 1_
- $a Kameník, Libor $u Department of Internal Medicine - Cardiology, 1st Faculty of Medicine, Charles University in Prague and Military University Hospital, Prague, Czech Republic $7 xx0121708
- 700 1_
- $a Littnerová, Simona $u Institute of Biostatistics and Analyses, Masaryk University, Brno, Czech Republic $7 jo2012694303
- 700 1_
- $a Sedloň, Pavel $u Department of Internal Medicine - Cardiology, 1st Faculty of Medicine, Charles University in Prague and Military University Hospital, Prague, Czech Republic $7 xx0130005
- 700 1_
- $a Luxová, Jana $u Department of Internal Medicine - Cardiology, 1st Faculty of Medicine, Charles University in Prague and Military University Hospital, Prague, Czech Republic $7 _AN045519
- 700 1_
- $a Fišerová, Marta $u Department of Internal Medicine - Cardiology, 1st Faculty of Medicine, Charles University in Prague and Military University Hospital, Prague, Czech Republic $7 _AN082545
- 700 1_
- $a Pospíšilová, Lenka $u Department of Clinical Biochemistry, Military University Hospital, Prague, Czech Republic $7 xx0142906
- 700 1_
- $a Hamouzová, Šárka $u Department of Internal Medicine - Cardiology, 1st Faculty of Medicine, Charles University in Prague and Military University Hospital, Prague, Czech Republic $7 _AN082546
- 700 1_
- $a Danek, Josef $u Department of Internal Medicine - Cardiology, 1st Faculty of Medicine, Charles University in Prague and Military University Hospital, Prague, Czech Republic
- 700 1_
- $a Zavoral, Miroslav, $u Department of Internal Medicine - Cardiology, 1st Faculty of Medicine, Charles University in Prague and Military University Hospital, Prague, Czech Republic $d 1953- $7 xx0036686
- 773 0_
- $w MED00012606 $t Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czech Republic $x 1213-8118 $g Roč. 160, č. 2 (2016), s. 248-256
- 910 __
- $a ABA008 $b A 1502 $c 958 $y 4 $z 0
- 990 __
- $a 20170413 $b ABA008
- 991 __
- $a 20170426084550 $b ABA008
- 999 __
- $a ok $b bmc $g 1205372 $s 973749
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2016 $b 160 $c 2 $d 248-256 $e 20160113 $i 1213-8118 $m Biomedical papers of the Medical Faculty of the University Palacký, Olomouc Czech Republic $n Biomed. Pap. Fac. Med. Palacký Univ. Olomouc Czech Repub. (Print) $x MED00012606
- LZP __
- $b NLK118 $a Pubmed-20170413