Evaluation of rheological parameters of the axial system using the Transfer Vibration through Spine (TVS) method
S. Panska, T. Piglova, J. Zeman, F. Marsik, F. Lopot, K. Jelen,
Language English Country Sweden
Document type Journal Article
PubMed
27857047
Knihovny.cz E-resources
- MeSH
- Biomechanical Phenomena MeSH
- Child MeSH
- Gymnastics * MeSH
- Humans MeSH
- Spine physiology MeSH
- Pilot Projects MeSH
- Rheology * MeSH
- Vibration * MeSH
- Viscosity MeSH
- Weight-Bearing physiology MeSH
- Check Tag
- Child MeSH
- Humans MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
OBJECTIVE: The human motion system reacts to both hypo and hyperactivity loads by changes to the rheological properties of tissues. This study deals with changes to the axial system (AS) compartment. Using the appropriate methodologies and mathematical-physical methods, these changes can be identified and quantified. METHODS: This study describes the noninvasive TVS (Transfer Vibration through Spine) method, which was applied to assess the AS selected mechanical properties in various modes. A pilot study was conducted on a top-level twelve-year-old girl-gymnast. The data detection was carried out in three cycles, before and after a peak 3.5 hour training session and the next day, after resting, just before the next training. RESULTS: Specifically, the values of selected rheological parameters, the AS damping coefficient b and viscosity μ, were obtained. The dynamics of their changes, in the stated load cycles, has also been shown. The damping coefficient b fell from the value of 0.626 to 0.324 before training and increased to 0.394 after resting. The viscosity coefficient μ showed a similar trend, namely falling from the value of 9.85 [Pa.s] to 2.15 [Pa.s] and then increasing to 3.8 [Pa.s] . CONCLUSIONS: With its computational solution, the TVS method,is a diagnostic apparatus making it possible to classify AS properties, both quantitatively and qualitatively, or its chosen segments and their changes, respectively. It can be used in classifying, preventing and treating the consequences of extreme motion and relaxing modes. The TVS application also makes it possible to control AS states over therapeutic, recovery, ergonomic and other loading modes of the human locomotion system.
Faculty of Engineering Czech University of Life Sciences Czech Republic
Institute of Thermomechanics of Academy of Sciences Czech Republic
- 000
- 00000naa a2200000 a 4500
- 001
- bmc17013398
- 003
- CZ-PrNML
- 005
- 20170418105642.0
- 007
- ta
- 008
- 170413s2016 sw f 000 0|eng||
- 009
- AR
- 035 __
- $a (PubMed)27857047
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a sw
- 100 1_
- $a Panska, Sarka $u Department of Anatomy and Biomechanics, Faculty of Physical Education and Sport, Laboratory of Biomechanics of Extreme Loading, Charles University, Czech Republic.
- 245 10
- $a Evaluation of rheological parameters of the axial system using the Transfer Vibration through Spine (TVS) method / $c S. Panska, T. Piglova, J. Zeman, F. Marsik, F. Lopot, K. Jelen,
- 520 9_
- $a OBJECTIVE: The human motion system reacts to both hypo and hyperactivity loads by changes to the rheological properties of tissues. This study deals with changes to the axial system (AS) compartment. Using the appropriate methodologies and mathematical-physical methods, these changes can be identified and quantified. METHODS: This study describes the noninvasive TVS (Transfer Vibration through Spine) method, which was applied to assess the AS selected mechanical properties in various modes. A pilot study was conducted on a top-level twelve-year-old girl-gymnast. The data detection was carried out in three cycles, before and after a peak 3.5 hour training session and the next day, after resting, just before the next training. RESULTS: Specifically, the values of selected rheological parameters, the AS damping coefficient b and viscosity μ, were obtained. The dynamics of their changes, in the stated load cycles, has also been shown. The damping coefficient b fell from the value of 0.626 to 0.324 before training and increased to 0.394 after resting. The viscosity coefficient μ showed a similar trend, namely falling from the value of 9.85 [Pa.s] to 2.15 [Pa.s] and then increasing to 3.8 [Pa.s] . CONCLUSIONS: With its computational solution, the TVS method,is a diagnostic apparatus making it possible to classify AS properties, both quantitatively and qualitatively, or its chosen segments and their changes, respectively. It can be used in classifying, preventing and treating the consequences of extreme motion and relaxing modes. The TVS application also makes it possible to control AS states over therapeutic, recovery, ergonomic and other loading modes of the human locomotion system.
- 650 _2
- $a biomechanika $7 D001696
- 650 _2
- $a dítě $7 D002648
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 12
- $a gymnastika $7 D006173
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a pilotní projekty $7 D010865
- 650 12
- $a reologie $7 D012212
- 650 _2
- $a páteř $x fyziologie $7 D013131
- 650 12
- $a vibrace $7 D014732
- 650 _2
- $a viskozita $7 D014783
- 650 _2
- $a zatížení muskuloskeletálního systému $x fyziologie $7 D016474
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Piglova, Tereza $u Department of Anatomy and Biomechanics, Faculty of Physical Education and Sport, Laboratory of Biomechanics of Extreme Loading, Charles University, Czech Republic.
- 700 1_
- $a Zeman, Josef $u Faculty of Engineering, Czech University of Life Sciences, Czech Republic.
- 700 1_
- $a Marsik, Frantisek $u Institute of Thermomechanics of Academy of Sciences, Czech Republic.
- 700 1_
- $a Lopot, Frantisek $u Department of Anatomy and Biomechanics, Faculty of Physical Education and Sport, Laboratory of Biomechanics of Extreme Loading, Charles University, Czech Republic.
- 700 1_
- $a Jelen, Karel $u Department of Anatomy and Biomechanics, Faculty of Physical Education and Sport, Laboratory of Biomechanics of Extreme Loading, Charles University, Czech Republic.
- 773 0_
- $w MED00168352 $t Neuro endocrinology letters $x 0172-780X $g Roč. 37, č. 4 (2016), s. 301-307
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/27857047 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20170413 $b ABA008
- 991 __
- $a 20170418105950 $b ABA008
- 999 __
- $a ok $b bmc $g 1199863 $s 974176
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2016 $b 37 $c 4 $d 301-307 $i 0172-780X $m Neuro-endocrinology letters $n Neuro-endocrinol. lett. $x MED00168352
- LZP __
- $a Pubmed-20170413