Je něco špatně v tomto záznamu ?
Accuracy of the FT-NIR Method in Evaluating the Fat Content of Milk Using Calibration Models Developed for the Reference Methods According to Röse-Gottlieb and Gerber
J. Mlcek, L. Dvorak, K. Sustova, K. Szwedziak,
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články
PubMed
27324807
DOI
10.5740/jaoacint.16-0107
Knihovny.cz E-zdroje
- MeSH
- blízká infračervená spektroskopie normy MeSH
- dietní tuky analýza MeSH
- kalibrace MeSH
- mléko chemie MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
The study examined the effect of the choice of reference method on the functionality and reliability of calibrations in near-IR (NIR) spectroscopy intended for measuring the fat content in raw cow's milk. The fat content in the milk samples was evaluated using methods according to either Röse-Gottlieb or Gerber. The same samples were then subjected to analysis on an Antaris FT-NIR spectrometer. Using a partial least-squares algorithm, calibration models were created for both methods from the values measured. The calibration models show very good values of standard error of calibration: 0.133 for the Gerber method and 0.095 for the Röse-Gottlieb method. These calibrations were subsequently used to analyze 30 new samples of cow's milk of undefined fat content, and the differences in the values were evaluated using statistical paired t-test to a median value at a probability level of α = 0.05. No statistically significant differences were found. It was revealed that the reference method used for calibrating the device evaluating the fat content in raw cow's milk has no effect on the functionality and reliability of the calibration model.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc17013755
- 003
- CZ-PrNML
- 005
- 20170426115555.0
- 007
- ta
- 008
- 170413s2016 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.5740/jaoacint.16-0107 $2 doi
- 035 __
- $a (PubMed)27324807
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Mlcek, Jiri $u Tomas Bata University in Zlin, Faculty of Technology, Department of Food Analysis and Chemistry, Vavreckova 275, 760 01 Zlin, Czech Republic.
- 245 10
- $a Accuracy of the FT-NIR Method in Evaluating the Fat Content of Milk Using Calibration Models Developed for the Reference Methods According to Röse-Gottlieb and Gerber / $c J. Mlcek, L. Dvorak, K. Sustova, K. Szwedziak,
- 520 9_
- $a The study examined the effect of the choice of reference method on the functionality and reliability of calibrations in near-IR (NIR) spectroscopy intended for measuring the fat content in raw cow's milk. The fat content in the milk samples was evaluated using methods according to either Röse-Gottlieb or Gerber. The same samples were then subjected to analysis on an Antaris FT-NIR spectrometer. Using a partial least-squares algorithm, calibration models were created for both methods from the values measured. The calibration models show very good values of standard error of calibration: 0.133 for the Gerber method and 0.095 for the Röse-Gottlieb method. These calibrations were subsequently used to analyze 30 new samples of cow's milk of undefined fat content, and the differences in the values were evaluated using statistical paired t-test to a median value at a probability level of α = 0.05. No statistically significant differences were found. It was revealed that the reference method used for calibrating the device evaluating the fat content in raw cow's milk has no effect on the functionality and reliability of the calibration model.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a kalibrace $7 D002138
- 650 _2
- $a dietní tuky $x analýza $7 D004041
- 650 _2
- $a mléko $x chemie $7 D008892
- 650 _2
- $a blízká infračervená spektroskopie $x normy $7 D019265
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Dvorak, Lukas $u Mendel University in Brno, Faculty of Agronomy, Department of Food Technology, Zemedelska 1, 613 00 Brno, Černá Pole, Czech Republic.
- 700 1_
- $a Sustova, Kvetoslava $u Mendel University in Brno, Faculty of Agronomy, Department of Food Technology, Zemedelska 1, 613 00 Brno, Černá Pole, Czech Republic.
- 700 1_
- $a Szwedziak, Katarzyna $u Opole University of Technology, Faculty of Production Engineering and Logistics, Department of Biosystems Engineering, 76 Proszkowska St, 45-758 Opole, Poland.
- 773 0_
- $w MED00002515 $t Journal of AOAC International $x 1060-3271 $g Roč. 99, č. 5 (2016), s. 1305-9
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/27324807 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20170413 $b ABA008
- 991 __
- $a 20170426115914 $b ABA008
- 999 __
- $a ok $b bmc $g 1200220 $s 974533
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2016 $b 99 $c 5 $d 1305-9 $e 20160617 $i 1060-3271 $m Journal of AOAC International $n J AOAC Int $x MED00002515
- LZP __
- $a Pubmed-20170413