-
Je něco špatně v tomto záznamu ?
Stereological quantification of microvessels using semiautomated evaluation of X-ray microtomography of hepatic vascular corrosion casts
M. Jiřík, Z. Tonar, A. Králíčková, L. Eberlová, H. Mírka, P. Kochová, T. Gregor, P. Hošek, M. Svobodová, E. Rohan, M. Králíčková, V. Liška,
Jazyk angličtina Země Německo
Typ dokumentu časopisecké články
- MeSH
- interpretace obrazu počítačem metody MeSH
- játra krevní zásobení diagnostické zobrazování MeSH
- koroze MeSH
- mikrocévy diagnostické zobrazování MeSH
- prasata MeSH
- rentgenová mikrotomografie metody MeSH
- software MeSH
- zobrazování trojrozměrné metody MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
PURPOSE: Quantitative description of hepatic microvascular bed could contribute to understanding perfusion CT imaging. Micro-CT is a useful method for the visualization and quantification of capillary-passable vascular corrosion casts. Our aim was to develop and validate open-source software for the statistical description of the vascular networks in micro-CT scans. METHODS: Porcine hepatic microvessels were injected with Biodur E20 resin, and the resulting corrosion casts were scanned with 1.9-4.7 [Formula: see text] resolution. The microvascular network was quantified using newly developed QuantAn software both in randomly selected volume probes (n = 10) and in arbitrarily outlined hepatic lobules (n = 4). The volumes, surfaces, lengths, and numbers of microvessel segments were estimated and validated in the same data sets with manual stereological counting. Calculations of tortuosity, radius histograms, length histograms, exports of the skeletonized vascular network into open formats, and an assessment of the degree of their anisotropy were performed. RESULTS: Within hepatic lobules, the microvessels had a volume fraction of 0.13 [Formula: see text] 0.05, surface density of 21.0 [Formula: see text] 2.0 [Formula: see text], length density of 169.0 [Formula: see text] 40.2 [Formula: see text], and numerical density of 588.5 [Formula: see text] 283.1 [Formula: see text]. Sensitivity analysis of the automatic analysis to binary opening, closing, threshold offset, and aggregation radius of branching nodes was performed. CONCLUSION: The software QuantAn and its source code are openly available to researchers working in the field of stochastic geometry of microvessels in micro-CT scans or other three-dimensional imaging methods. The implemented methods comply with reproducible stereological techniques, and they were highly consistent with manual counting. Preliminary morphometrics of the classical hepatic lobules in pig were provided.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc17013999
- 003
- CZ-PrNML
- 005
- 20180523133046.0
- 007
- ta
- 008
- 170413s2016 gw f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1007/s11548-016-1378-3 $2 doi
- 035 __
- $a (PubMed)27008472
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Jiřík, Miroslav $u European Centre of Excellence NTIS, Faculty of Applied Sciences, University of West Bohemia, Univerzitní 22, 306 14, Pilsen, Czech Republic. Biomedical Center, Faculty of Medicine in Pilsen, Charles University in Prague, Alej Svobody 76, 323 00, Pilsen, Czech Republic.
- 245 10
- $a Stereological quantification of microvessels using semiautomated evaluation of X-ray microtomography of hepatic vascular corrosion casts / $c M. Jiřík, Z. Tonar, A. Králíčková, L. Eberlová, H. Mírka, P. Kochová, T. Gregor, P. Hošek, M. Svobodová, E. Rohan, M. Králíčková, V. Liška,
- 520 9_
- $a PURPOSE: Quantitative description of hepatic microvascular bed could contribute to understanding perfusion CT imaging. Micro-CT is a useful method for the visualization and quantification of capillary-passable vascular corrosion casts. Our aim was to develop and validate open-source software for the statistical description of the vascular networks in micro-CT scans. METHODS: Porcine hepatic microvessels were injected with Biodur E20 resin, and the resulting corrosion casts were scanned with 1.9-4.7 [Formula: see text] resolution. The microvascular network was quantified using newly developed QuantAn software both in randomly selected volume probes (n = 10) and in arbitrarily outlined hepatic lobules (n = 4). The volumes, surfaces, lengths, and numbers of microvessel segments were estimated and validated in the same data sets with manual stereological counting. Calculations of tortuosity, radius histograms, length histograms, exports of the skeletonized vascular network into open formats, and an assessment of the degree of their anisotropy were performed. RESULTS: Within hepatic lobules, the microvessels had a volume fraction of 0.13 [Formula: see text] 0.05, surface density of 21.0 [Formula: see text] 2.0 [Formula: see text], length density of 169.0 [Formula: see text] 40.2 [Formula: see text], and numerical density of 588.5 [Formula: see text] 283.1 [Formula: see text]. Sensitivity analysis of the automatic analysis to binary opening, closing, threshold offset, and aggregation radius of branching nodes was performed. CONCLUSION: The software QuantAn and its source code are openly available to researchers working in the field of stochastic geometry of microvessels in micro-CT scans or other three-dimensional imaging methods. The implemented methods comply with reproducible stereological techniques, and they were highly consistent with manual counting. Preliminary morphometrics of the classical hepatic lobules in pig were provided.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a koroze $7 D003343
- 650 _2
- $a interpretace obrazu počítačem $x metody $7 D007090
- 650 _2
- $a zobrazování trojrozměrné $x metody $7 D021621
- 650 _2
- $a játra $x krevní zásobení $x diagnostické zobrazování $7 D008099
- 650 _2
- $a mikrocévy $x diagnostické zobrazování $7 D055806
- 650 _2
- $a software $7 D012984
- 650 _2
- $a prasata $7 D013552
- 650 _2
- $a rentgenová mikrotomografie $x metody $7 D055114
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Tonar, Zbyněk $u European Centre of Excellence NTIS, Faculty of Applied Sciences, University of West Bohemia, Univerzitní 22, 306 14, Pilsen, Czech Republic. zbynek.tonar@lfp.cuni.cz.
- 700 1_
- $a Králíčková, Anna $u Department of Histology and Embryology, Faculty of Medicine in Pilsen, Charles University in Prague, Karlovarska 48, 301 66, Pilsen, Czech Republic.
- 700 1_
- $a Eberlová, Lada $u Department of Anatomy, Faculty of Medicine in Pilsen, Charles University in Prague, Karlovarska 48, 301 66, Pilsen, Czech Republic. Biomedical Center, Faculty of Medicine in Pilsen, Charles University in Prague, Alej Svobody 76, 323 00, Pilsen, Czech Republic.
- 700 1_
- $a Mírka, Hynek $u Department of Imaging methods, Faculty of Medicine and University Hospital in Pilsen, Alej Svobody 80, 304 60, Pilsen, Czech Republic. Biomedical Center, Faculty of Medicine in Pilsen, Charles University in Prague, Alej Svobody 76, 323 00, Pilsen, Czech Republic.
- 700 1_
- $a Kochová, Petra $u European Centre of Excellence NTIS, Faculty of Applied Sciences, University of West Bohemia, Univerzitní 22, 306 14, Pilsen, Czech Republic.
- 700 1_
- $a Gregor, Tomáš $u New Technologies - Research Centre, University of West Bohemia, Univerzitní 8, 306 14, Pilsen, Czech Republic.
- 700 1_
- $a Hošek, Petr $u Biomedical Center, Faculty of Medicine in Pilsen, Charles University in Prague, Alej Svobody 76, 323 00, Pilsen, Czech Republic. $7 xx0224573
- 700 1_
- $a Svobodová, Miroslava $u Biomedical Center, Faculty of Medicine in Pilsen, Charles University in Prague, Alej Svobody 76, 323 00, Pilsen, Czech Republic.
- 700 1_
- $a Rohan, Eduard $u European Centre of Excellence NTIS, Faculty of Applied Sciences, University of West Bohemia, Univerzitní 22, 306 14, Pilsen, Czech Republic.
- 700 1_
- $a Králíčková, Milena $u Department of Histology and Embryology, Faculty of Medicine in Pilsen, Charles University in Prague, Karlovarska 48, 301 66, Pilsen, Czech Republic. Biomedical Center, Faculty of Medicine in Pilsen, Charles University in Prague, Alej Svobody 76, 323 00, Pilsen, Czech Republic.
- 700 1_
- $a Liška, Václav $u Biomedical Center, Faculty of Medicine in Pilsen, Charles University in Prague, Alej Svobody 76, 323 00, Pilsen, Czech Republic. Department of Surgery, Faculty of Medicine in Pilsen, Charles University in Prague, Husova 3, 306 05, Pilsen, Czech Republic.
- 773 0_
- $w MED00184797 $t International journal of computer assisted radiology and surgery $x 1861-6429 $g Roč. 11, č. 10 (2016), s. 1803-19
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/27008472 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20170413 $b ABA008
- 991 __
- $a 20180523133231 $b ABA008
- 999 __
- $a ok $b bmc $g 1200464 $s 974777
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2016 $b 11 $c 10 $d 1803-19 $e 20160323 $i 1861-6429 $m International journal of computer assisted radiology and surgery $n Int J Comput Assist Radiol Surg $x MED00184797
- LZP __
- $a Pubmed-20170413