-
Something wrong with this record ?
How to choose between the implant materials steel and titanium in orthopedic trauma surgery. Part 1, Mechanical aspects [Jak zvolit mezi ocelovými a titanovými implantáty v ortopedické traumatologii. Část 1, Mechanické aspekty]
S. M. Perren, P. Regazzoni, A. A. Fernandez
Language English Country Czech Republic
Document type Journal Article
PubMed
28253940
Knihovny.cz E-resources
- MeSH
- Biomechanical Phenomena MeSH
- Humans MeSH
- Steel MeSH
- Orthopedic Procedures instrumentation MeSH
- Prostheses and Implants * MeSH
- Materials Testing MeSH
- Titanium MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
When choosing between metal implants of different materials the surgeon mainly needs to balance the pros and cons of steel and titanium. Economic constraints often do not permit both to be kept in stock and it is necessary to decide beforehand which to choose. The arguments for the use of the "preferred metal" vary. The present paper elucidates the practical aspects based on the complex scientific background that has identified the differences between the two metals in their mechanical, electrochemical, biological and application behavior. The data presented here are intended to help the surgeon when he is confronted with different and often complex clinical situations and problems. The following is an overview of different aspects to help with selection of the proper material for the clinical application. The first part concerns mechanical aspects the second part the biological aspects. Both aspects are discussed with the practical application in mind. Nonmetallic implant materials have seen an increasing interest in the recent past. Plastic materials needed improvement to achieve good strength and avoid creep with loss of e.g. compression and minimizing leakage of chemicals.
Jak zvolit mezi ocelovými a titanovými implantáty v ortopedické traumatologii. Část 1, Mechanické aspekty
- 000
- 00000naa a2200000 a 4500
- 001
- bmc17016748
- 003
- CZ-PrNML
- 005
- 20170601072924.0
- 007
- ta
- 008
- 170516s2017 xr ad f 000 0|eng||
- 009
- AR
- 024 7_
- $2 doi $a 10.55095/achot2017/001
- 035 __
- $a (PubMed)28253940
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng $b cze
- 044 __
- $a xr
- 100 1_
- $a Perren, S. M. $u Davos, Switzerland
- 245 10
- $a How to choose between the implant materials steel and titanium in orthopedic trauma surgery. $n Part 1, $p Mechanical aspects / $c S. M. Perren, P. Regazzoni, A. A. Fernandez
- 246 31
- $a Jak zvolit mezi ocelovými a titanovými implantáty v ortopedické traumatologii. $n Část 1, $p Mechanické aspekty
- 520 9_
- $a When choosing between metal implants of different materials the surgeon mainly needs to balance the pros and cons of steel and titanium. Economic constraints often do not permit both to be kept in stock and it is necessary to decide beforehand which to choose. The arguments for the use of the "preferred metal" vary. The present paper elucidates the practical aspects based on the complex scientific background that has identified the differences between the two metals in their mechanical, electrochemical, biological and application behavior. The data presented here are intended to help the surgeon when he is confronted with different and often complex clinical situations and problems. The following is an overview of different aspects to help with selection of the proper material for the clinical application. The first part concerns mechanical aspects the second part the biological aspects. Both aspects are discussed with the practical application in mind. Nonmetallic implant materials have seen an increasing interest in the recent past. Plastic materials needed improvement to achieve good strength and avoid creep with loss of e.g. compression and minimizing leakage of chemicals.
- 650 _2
- $a biomechanika $7 D001696
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a testování materiálů $7 D008422
- 650 _2
- $a ortopedické výkony $x přístrojové vybavení $7 D019637
- 650 12
- $a protézy a implantáty $7 D019736
- 650 _2
- $a ocel $7 D013232
- 650 _2
- $a titan $7 D014025
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Regazzoni, P. $u Lugano Soragno, Switzerland
- 700 1_
- $a Fernandez, A. A. $u Hospital Britanico, Montevideo, Uruguay
- 773 0_
- $w MED00011021 $t Acta chirurgiae orthopaedicae et traumatologiae Čechoslovaca $x 0001-5415 $g Roč. 84, č. 1 (2017), s. 9-12
- 910 __
- $a ABA008 $b A 8 $c 507 $y 4 $z 0
- 990 __
- $a 20170516 $b ABA008
- 991 __
- $a 20170601073328 $b ABA008
- 999 __
- $a ok $b bmc $g 1208052 $s 977557
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2017 $b 84 $c 1 $d 9-12 $i 0001-5415 $m Acta chirurgiae orthopaedicae et traumatologiae Čechoslovaca $n Acta chir. orthop. traumatol. Čechoslovaca $x MED00011021
- LZP __
- $b NLK118 $a Pubmed-20170516