Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Phone camera detection of glucose blood level based on magnetic particles entrapped inside bubble wrap

P. Martinkova, M. Pohanka,

. 2016 ; 37 (Suppl1) : 132-138.

Jazyk angličtina Země Švédsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc17023224

OBJECTIVES: Glucose is an important diagnostic biochemical marker of diabetes but also for organophosphates, carbamates, acetaminophens or salicylates poisoning. Hence, innovation of accurate and fast detection assay is still one of priorities in biomedical research. METHODS: Glucose sensor based on magnetic particles (MPs) with immobilized enzymes glucose oxidase (GOx) and horseradish peroxidase (HRP) was developed and the GOx catalyzed reaction was visualized by a smart-phone-integrated camera. RESULTS: Exponential decay concentration curve with correlation coefficient 0.997 and with limit of detection 0.4 mmol/l was achieved. Interfering and matrix substances were measured due to possibility of assay influencing and no effect of the tested substances was observed. Spiked plasma samples were also measured and no influence of plasma matrix on the assay was proved. CONCLUSIONS: The presented assay showed complying results with reference method (standard spectrophotometry based on enzymes glucose oxidase and peroxidase inside plastic cuvettes) with linear dependence and correlation coefficient 0.999 in concentration range between 0 and 4 mmol/l. On the grounds of measured results, method was considered as highly specific, accurate and fast assay for detection of glucose.

000      
00000naa a2200000 a 4500
001      
bmc17023224
003      
CZ-PrNML
005      
20170720124427.0
007      
ta
008      
170720s2016 sw f 000 0|eng||
009      
AR
035    __
$a (PubMed)28263541
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a sw
100    1_
$a Martinkova, Pavla $u Faculty of Military Health Sciences, University of Defence, Hradec Kralove, Czech Republic.
245    10
$a Phone camera detection of glucose blood level based on magnetic particles entrapped inside bubble wrap / $c P. Martinkova, M. Pohanka,
520    9_
$a OBJECTIVES: Glucose is an important diagnostic biochemical marker of diabetes but also for organophosphates, carbamates, acetaminophens or salicylates poisoning. Hence, innovation of accurate and fast detection assay is still one of priorities in biomedical research. METHODS: Glucose sensor based on magnetic particles (MPs) with immobilized enzymes glucose oxidase (GOx) and horseradish peroxidase (HRP) was developed and the GOx catalyzed reaction was visualized by a smart-phone-integrated camera. RESULTS: Exponential decay concentration curve with correlation coefficient 0.997 and with limit of detection 0.4 mmol/l was achieved. Interfering and matrix substances were measured due to possibility of assay influencing and no effect of the tested substances was observed. Spiked plasma samples were also measured and no influence of plasma matrix on the assay was proved. CONCLUSIONS: The presented assay showed complying results with reference method (standard spectrophotometry based on enzymes glucose oxidase and peroxidase inside plastic cuvettes) with linear dependence and correlation coefficient 0.999 in concentration range between 0 and 4 mmol/l. On the grounds of measured results, method was considered as highly specific, accurate and fast assay for detection of glucose.
650    _2
$a biotest $x metody $x normy $7 D001681
650    _2
$a biosenzitivní techniky $x metody $7 D015374
650    _2
$a krevní glukóza $x metabolismus $7 D001786
650    _2
$a enzymy imobilizované $x metabolismus $7 D004800
650    _2
$a glukosaoxidasa $x metabolismus $7 D005949
650    _2
$a křenová peroxidasa $x metabolismus $7 D006735
650    _2
$a lidé $7 D006801
650    _2
$a chytrý telefon $x využití $7 D000068997
655    _2
$a časopisecké články $7 D016428
700    1_
$a Pohanka, Miroslav $u Faculty of Military Health Sciences, University of Defence, Hradec Kralove, Czech Republic.
773    0_
$w MED00168352 $t Neuro endocrinology letters $x 0172-780X $g Roč. 37, Suppl1 (2016), s. 132-138
856    41
$u https://pubmed.ncbi.nlm.nih.gov/28263541 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20170720 $b ABA008
991    __
$a 20170720124920 $b ABA008
999    __
$a ok $b bmc $g 1238905 $s 984137
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2016 $b 37 $c Suppl1 $d 132-138 $i 0172-780X $m Neuro-endocrinology letters $n Neuro-endocrinol. lett. $x MED00168352
LZP    __
$a Pubmed-20170720

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...