• Je něco špatně v tomto záznamu ?

Non-invasive diagnostic system and its opto-mechanical probe for combining confocal Raman spectroscopy and optical coherence tomography

J. Klemes, A. Kotzianova, M. Pokorny, P. Mojzes, J. Novak, L. Sukova, J. Demuth, J. Vesely, L. Sasek, V. Velebny,

. 2017 ; 10 (11) : 1442-1449. [pub] 20170502

Jazyk angličtina Země Německo

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc18025055

Non-invasive optical diagnostic methods allow important information about studied systems to be obtained in a non-destructive way. Complete diagnosis requires information about the chemical composition as well as the morphological structure of a sample. We report on the development of an opto-mechanical probe that combines Raman spectroscopy (RS) and optical coherence tomography (OCT), two methods that provide all the crucial information needed for a non-invasive diagnosis. The aim of this paper is to introduce the technical design, construction and optimization of a dual opto-mechanical probe combining two in-house developed devices for confocal RS and OCT. The unique benefit of the probe is a gradual acquisition of OCT and RS data, which allows to use the acquired OCT images to pinpoint locations of interest for RS measurements. The parameters and the correct functioning of the probe were verified by RS scanning of various samples (silicon wafer and ex vivo tissue) based on their OCT images - lateral as well as depth scanning was performed. Both the OCT and RS systems were developed, optimized and tested with the ultimate aim of verifying the functionality of the probe. Picture: Schematic illustration and visualization of the developed RS-OCT probe.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc18025055
003      
CZ-PrNML
005      
20180716115832.0
007      
ta
008      
180709s2017 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1002/jbio.201600284 $2 doi
035    __
$a (PubMed)28464557
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Klemes, Jan $u Contipro a.s., R&D Department, CZ-56102, Dolni Dobrouc, Czech Republic.
245    10
$a Non-invasive diagnostic system and its opto-mechanical probe for combining confocal Raman spectroscopy and optical coherence tomography / $c J. Klemes, A. Kotzianova, M. Pokorny, P. Mojzes, J. Novak, L. Sukova, J. Demuth, J. Vesely, L. Sasek, V. Velebny,
520    9_
$a Non-invasive optical diagnostic methods allow important information about studied systems to be obtained in a non-destructive way. Complete diagnosis requires information about the chemical composition as well as the morphological structure of a sample. We report on the development of an opto-mechanical probe that combines Raman spectroscopy (RS) and optical coherence tomography (OCT), two methods that provide all the crucial information needed for a non-invasive diagnosis. The aim of this paper is to introduce the technical design, construction and optimization of a dual opto-mechanical probe combining two in-house developed devices for confocal RS and OCT. The unique benefit of the probe is a gradual acquisition of OCT and RS data, which allows to use the acquired OCT images to pinpoint locations of interest for RS measurements. The parameters and the correct functioning of the probe were verified by RS scanning of various samples (silicon wafer and ex vivo tissue) based on their OCT images - lateral as well as depth scanning was performed. Both the OCT and RS systems were developed, optimized and tested with the ultimate aim of verifying the functionality of the probe. Picture: Schematic illustration and visualization of the developed RS-OCT probe.
650    12
$a mechanické jevy $7 D055595
650    _2
$a software $7 D012984
650    _2
$a Ramanova spektroskopie $x přístrojové vybavení $x metody $7 D013059
650    _2
$a systémová integrace $7 D018511
650    _2
$a optická koherentní tomografie $x přístrojové vybavení $x metody $7 D041623
655    _2
$a časopisecké články $7 D016428
700    1_
$a Kotzianova, Adela $u Contipro a.s., R&D Department, CZ-56102, Dolni Dobrouc, Czech Republic. Masaryk University, Faculty of Science, Department of Chemistry, CZ-62500, Brno, Czech Republic.
700    1_
$a Pokorny, Marek $u Contipro a.s., R&D Department, CZ-56102, Dolni Dobrouc, Czech Republic.
700    1_
$a Mojzes, Peter $u Charles University, Faculty of Mathematics and Physics, Institute of Physics, CZ-12116, Prague, Czech Republic.
700    1_
$a Novak, Jindrich $u Nanoware, CZ-14800, Praha 4, Czech Republic.
700    1_
$a Sukova, Lada $u Contipro a.s., R&D Department, CZ-56102, Dolni Dobrouc, Czech Republic.
700    1_
$a Demuth, Jaroslav $u Safibra s.r.o., CZ-25101, Ricany, Czech Republic.
700    1_
$a Vesely, Jaroslav $u Safibra s.r.o., CZ-25101, Ricany, Czech Republic.
700    1_
$a Sasek, Ladislav $u Safibra s.r.o., CZ-25101, Ricany, Czech Republic.
700    1_
$a Velebny, Vladimir $u Contipro a.s., R&D Department, CZ-56102, Dolni Dobrouc, Czech Republic.
773    0_
$w MED00157626 $t Journal of biophotonics $x 1864-0648 $g Roč. 10, č. 11 (2017), s. 1442-1449
856    41
$u https://pubmed.ncbi.nlm.nih.gov/28464557 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20180709 $b ABA008
991    __
$a 20180716120130 $b ABA008
999    __
$a ok $b bmc $g 1317186 $s 1021976
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2017 $b 10 $c 11 $d 1442-1449 $e 20170502 $i 1864-0648 $m Journal of biophotonics $n J Biophotonics $x MED00157626
LZP    __
$a Pubmed-20180709

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...