Ultrasound detection of diaphragm position in the region for lung monitoring by electrical impedance tomography during laparoscopy

K. Buzkova, M. Muller, A. Rara, K. Roubik, T. Tyll

. 2018 ; 162 (1) : 43-46. [pub] 20180221

Jazyk angličtina Země Česko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc18032329

BACKGROUND AND AIMS: During laparoscopic surgery, a capnoperitoneum is created to optimize the operating space for surgeons. One effect of this is abdominal pressure which alters the physiological thoraco-abdominal configuration and pushes the diaphragm and lungs cranially. Since the lung image acquired by electrical impedance tomography (EIT) depends on the conditions within the thorax and abdomen, it is crucial to know the diaphragm position to determine the effect of diaphragm shift on EIT thorax image. METHODS: The presence of diaphragm in the region of EIT measurement was determined by ultrasound in 20 patients undergoing laparoscopic surgery. Data were obtained in the supine position during spontaneous breathing in a mechanically ventilated patient under general anesthesia with muscle relaxation and in a mechanically ventilated patient under general anesthesia with muscle relaxation during capnoperitoneum. RESULTS: The diaphragm was shifted cranially during capnoperitoneum. The diaphragm detection rate rose by 10% during capnoperitoneum at the fifth intercostal space, from 55% to 65% and by 10% from 0% at mid-sternal level compared to mechanical ventilation without capnoperitoneum. CONCLUSION: The diaphragm was detected in the area contributing to the creation of the thoracic EIT image. Considering the cranial shift of diaphragm caused by excessive intra-abdominal pressure, the impedance changes in the abdomen and the principle of EIT, we assume there could be a significant impact on EIT image of the thorax acquired during capnoperitoneum. For this reason, for lung monitoring using EIT during capnoperitoneum, the manufacturer's recommendation for electrode belt position is not appropriate. The study was registered in ClinicalTrials.gov with an identifier NCT03038061.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc18032329
003      
CZ-PrNML
005      
20181017150124.0
007      
ta
008      
181001s2018 xr f 000 0|eng||
009      
AR
024    7_
$a 10.5507/bp.2018.005 $2 doi
035    __
$a (PubMed)29467544
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Buzková, Kristýna $u Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical Universty in Prague, Czech Republic $7 xx0228396
245    10
$a Ultrasound detection of diaphragm position in the region for lung monitoring by electrical impedance tomography during laparoscopy / $c K. Buzkova, M. Muller, A. Rara, K. Roubik, T. Tyll
520    9_
$a BACKGROUND AND AIMS: During laparoscopic surgery, a capnoperitoneum is created to optimize the operating space for surgeons. One effect of this is abdominal pressure which alters the physiological thoraco-abdominal configuration and pushes the diaphragm and lungs cranially. Since the lung image acquired by electrical impedance tomography (EIT) depends on the conditions within the thorax and abdomen, it is crucial to know the diaphragm position to determine the effect of diaphragm shift on EIT thorax image. METHODS: The presence of diaphragm in the region of EIT measurement was determined by ultrasound in 20 patients undergoing laparoscopic surgery. Data were obtained in the supine position during spontaneous breathing in a mechanically ventilated patient under general anesthesia with muscle relaxation and in a mechanically ventilated patient under general anesthesia with muscle relaxation during capnoperitoneum. RESULTS: The diaphragm was shifted cranially during capnoperitoneum. The diaphragm detection rate rose by 10% during capnoperitoneum at the fifth intercostal space, from 55% to 65% and by 10% from 0% at mid-sternal level compared to mechanical ventilation without capnoperitoneum. CONCLUSION: The diaphragm was detected in the area contributing to the creation of the thoracic EIT image. Considering the cranial shift of diaphragm caused by excessive intra-abdominal pressure, the impedance changes in the abdomen and the principle of EIT, we assume there could be a significant impact on EIT image of the thorax acquired during capnoperitoneum. For this reason, for lung monitoring using EIT during capnoperitoneum, the manufacturer's recommendation for electrode belt position is not appropriate. The study was registered in ClinicalTrials.gov with an identifier NCT03038061.
650    _2
$a senioři $7 D000368
650    _2
$a bránice $x diagnostické zobrazování $7 D003964
650    12
$a elektrická impedance $7 D017097
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a lidé $7 D006801
650    12
$a laparoskopie $7 D010535
650    _2
$a plíce $x diagnostické zobrazování $7 D008168
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    _2
$a pneumoperitoneum umělé $x metody $7 D011028
650    _2
$a ventilace umělá s výdechovým přetlakem $7 D011175
650    _2
$a prospektivní studie $7 D011446
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a hrudník $x diagnostické zobrazování $7 D013909
650    12
$a počítačová rentgenová tomografie $7 D014057
655    _2
$a časopisecké články $7 D016428
700    1_
$a Müller, Martin $u Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical Universty in Prague, Czech Republic; Department of Anesthesiology, Resuscitation and Intensive Care Medicine First Faculty of Medicine Charles University and the Military University Hospital Prague, Czech Republic $7 xx0228490
700    1_
$a Rára, Aleš $u Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical Universty in Prague, Czech Republic; Department of Anesthesiology, Resuscitation and Intensive Care Medicine First Faculty of Medicine Charles University and the Military University Hospital Prague, Czech Republic $7 xx0209865
700    1_
$a Roubík, Karel, $u Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical Universty in Prague, Czech Republic $d 1971- $7 ntka173892
700    1_
$a Tyll, Tomáš, $u Department of Anesthesiology, Resuscitation and Intensive Care Medicine First Faculty of Medicine Charles University and the Military University Hospital Prague, Czech Republic $d 1969- $7 xx0031798
773    0_
$w MED00012606 $t Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czech Republic $x 1213-8118 $g Roč. 162, č. 1 (2018), s. 43-46
856    41
$u https://pubmed.ncbi.nlm.nih.gov/29467544 $y Pubmed
910    __
$a ABA008 $b A 1502 $c 958 $y 4 $z 0
990    __
$a 20181001 $b ABA008
991    __
$a 20181016085904 $b ABA008
999    __
$a ok $b bmc $g 1343534 $s 1029320
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2018 $b 162 $c 1 $d 43-46 $e 20180221 $i 1213-8118 $m Biomedical papers of the Medical Faculty of the University Palacký, Olomouc Czech Republic $n Biomed. Pap. Fac. Med. Palacký Univ. Olomouc Czech Repub. (Print) $x MED00012606
LZP    __
$b NLK118 $a Pubmed-20181001

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...