-
Je něco špatně v tomto záznamu ?
Glucose sensing on graphite screen-printed electrode modified by sparking of copper nickel alloys
D. Riman, K. Spyrou, AE. Karantzalis, J. Hrbac, MI. Prodromidis,
Jazyk angličtina Země Nizozemsko
Typ dokumentu časopisecké články
- MeSH
- biosenzitivní techniky metody MeSH
- elektrochemické techniky metody MeSH
- elektrody * MeSH
- glukosa analýza MeSH
- grafit chemie MeSH
- lidé MeSH
- limita detekce MeSH
- měď chemie MeSH
- nikl chemie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
Electric spark discharge was employed as a green, fast and extremely facile method to modify disposable graphite screen-printed electrodes (SPEs) with copper, nickel and mixed copper/nickel nanoparticles (NPs) in order to be used as nonenzymatic glucose sensors. Direct SPEs-to-metal (copper, nickel or copper/nickel alloys with 25/75, 50/50 and 75/25wt% compositions) sparking at 1.2kV was conducted in the absence of any solutions under ambient conditions. Morphological characterization of the sparked surfaces was performed by scanning electron microscopy, while the chemical composition of the sparked NPs was evaluated with energy dispersive X-ray spectroscopy and X-ray photoelectron spectroscopy. The performance of the various sparked SPEs towards the electro oxidation of glucose in alkaline media and the critical role of hydroxyl ions were evaluated with cyclic voltammetry and kinetic studies. Results indicated a mixed charge transfer- and hyroxyl ion transport-limited process. Best performing sensors fabricated by Cu/Ni 50/50wt% alloy showed linear response over the concentration range 2-400μM glucose and they were successfully applied to the amperometric determination of glucose in blood. The detection limit (S/N 3) and the relative standard deviation of the method were 0.6µM and <6% (n=5, 2µM glucose), respectively. Newly devised sparked Cu/Ni graphite SPEs enable glucose sensing with distinct advantages over existing glucose chemical sensors in terms of cost, fabrication simplicity, disposability, and adaptation of green methods in sensor's development.
Department of Analytical Chemistry Palacky University 771 46 Olomouc Czech Republic
Department of Chemistry Masaryk University 625 00 Brno Czech Republic
Department of Chemistry University of Ioannina Ioannina 451 10 Greece
Department of Materials Science and Engineering University of Ioannina Ioannina 451 10 Greece
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc18034009
- 003
- CZ-PrNML
- 005
- 20181008122222.0
- 007
- ta
- 008
- 181008s2017 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.talanta.2016.12.064 $2 doi
- 035 __
- $a (PubMed)28153284
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Riman, Daniel $u Department of Analytical Chemistry, Palacky University, 771 46 Olomouc, Czech Republic.
- 245 10
- $a Glucose sensing on graphite screen-printed electrode modified by sparking of copper nickel alloys / $c D. Riman, K. Spyrou, AE. Karantzalis, J. Hrbac, MI. Prodromidis,
- 520 9_
- $a Electric spark discharge was employed as a green, fast and extremely facile method to modify disposable graphite screen-printed electrodes (SPEs) with copper, nickel and mixed copper/nickel nanoparticles (NPs) in order to be used as nonenzymatic glucose sensors. Direct SPEs-to-metal (copper, nickel or copper/nickel alloys with 25/75, 50/50 and 75/25wt% compositions) sparking at 1.2kV was conducted in the absence of any solutions under ambient conditions. Morphological characterization of the sparked surfaces was performed by scanning electron microscopy, while the chemical composition of the sparked NPs was evaluated with energy dispersive X-ray spectroscopy and X-ray photoelectron spectroscopy. The performance of the various sparked SPEs towards the electro oxidation of glucose in alkaline media and the critical role of hydroxyl ions were evaluated with cyclic voltammetry and kinetic studies. Results indicated a mixed charge transfer- and hyroxyl ion transport-limited process. Best performing sensors fabricated by Cu/Ni 50/50wt% alloy showed linear response over the concentration range 2-400μM glucose and they were successfully applied to the amperometric determination of glucose in blood. The detection limit (S/N 3) and the relative standard deviation of the method were 0.6µM and <6% (n=5, 2µM glucose), respectively. Newly devised sparked Cu/Ni graphite SPEs enable glucose sensing with distinct advantages over existing glucose chemical sensors in terms of cost, fabrication simplicity, disposability, and adaptation of green methods in sensor's development.
- 650 _2
- $a biosenzitivní techniky $x metody $7 D015374
- 650 _2
- $a měď $x chemie $7 D003300
- 650 _2
- $a elektrochemické techniky $x metody $7 D055664
- 650 12
- $a elektrody $7 D004566
- 650 _2
- $a glukosa $x analýza $7 D005947
- 650 _2
- $a grafit $x chemie $7 D006108
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a limita detekce $7 D057230
- 650 _2
- $a nikl $x chemie $7 D009532
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Spyrou, Konstantinos $u Department of Materials Science and Engineering, University of Ioannina, Ioannina 451 10, Greece.
- 700 1_
- $a Karantzalis, Alexandros E $u Department of Materials Science and Engineering, University of Ioannina, Ioannina 451 10, Greece.
- 700 1_
- $a Hrbac, Jan $u Department of Chemistry, Masaryk University, 625 00 Brno, Czech Republic. Electronic address: jhrbac@atlas.cz.
- 700 1_
- $a Prodromidis, Mamas I $u Department of Chemistry, University of Ioannina, Ioannina 451 10, Greece. Electronic address: mprodrom@cc.uoi.gr.
- 773 0_
- $w MED00004484 $t Talanta $x 1873-3573 $g Roč. 165, č. - (2017), s. 466-473
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/28153284 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20181008 $b ABA008
- 991 __
- $a 20181008122709 $b ABA008
- 999 __
- $a ok $b bmc $g 1339688 $s 1031003
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2017 $b 165 $c - $d 466-473 $e 20161224 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
- LZP __
- $a Pubmed-20181008