• Je něco špatně v tomto záznamu ?

Thermoresponsive Polymers for Nuclear Medicine: Which Polymer Is the Best

O. Sedláček, P. Černoch, J. Kučka, R. Konefal, P. Štěpánek, M. Vetrík, TP. Lodge, M. Hrubý,

. 2016 ; 32 (24) : 6115-22. [pub] 20160606

Jazyk angličtina Země Spojené státy americké

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc18034128

Grantová podpora
NV15-25781A MZ0 CEP - Centrální evidence projektů

Thermoresponsive polymers showing cloud point temperatures (CPT) in aqueous solutions are very promising for the construction of various systems in biomedical field. In many of these applications these polymers get in contact with ionizing radiation, e.g., if they are used as carriers for radiopharmaceuticals or during radiation sterilization. Despite this fact, radiosensitivity of these polymers is largely overlooked to date. In this work, we describe the effect of electron beam ionizing radiation on the physicochemical and phase separation properties of selected thermoresponsive polymers with CPT between room and body temperature. Stability of the polymers to radiation (doses 0-20 kGy) in aqueous solutions increased in the order poly(N-vinylcaprolactam) (PVCL, the least stable) ≪ poly[N-(2,2-difluoroethyl)acrylamide] (DFP) < poly(N-isopropylacrylamide) (PNIPAM) ≪ poly(2-isopropyl-2-oxazoline-co-2-n-butyl-2-oxazoline) (POX). Even low doses of β radiation (1 kGy), which are highly relevant to the storage of polymer radiotherapeutics and sterilization of biomedical systems, cause significant increase in molecular weight due to cross-linking (except for POX, where this effect is weak). In the case of PVCL irradiated with low doses, the increase in molecular weight induced an increase in the CPT of the polymer. For PNIPAM and DFP, there is strong chain hydrophilization leading to an increase in CPT. From this perspective, POX is the most suitable polymer for the construction of delivery systems that experience exposure to radiation, while PVCL is the least suitable and PNIPAM and DFP are suitable only for low radiation demands.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc18034128
003      
CZ-PrNML
005      
20201014141933.0
007      
ta
008      
181008s2016 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1021/acs.langmuir.6b01527 $2 doi
035    __
$a (PubMed)27238593
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Sedláček, Ondřej $u Institute of Macromolecular Chemistry, v.v.i., Academy of Sciences of the Czech Republic , Heyrovsky Sq. 2, 162 06 Prague 6, Czech Republic.
245    10
$a Thermoresponsive Polymers for Nuclear Medicine: Which Polymer Is the Best / $c O. Sedláček, P. Černoch, J. Kučka, R. Konefal, P. Štěpánek, M. Vetrík, TP. Lodge, M. Hrubý,
520    9_
$a Thermoresponsive polymers showing cloud point temperatures (CPT) in aqueous solutions are very promising for the construction of various systems in biomedical field. In many of these applications these polymers get in contact with ionizing radiation, e.g., if they are used as carriers for radiopharmaceuticals or during radiation sterilization. Despite this fact, radiosensitivity of these polymers is largely overlooked to date. In this work, we describe the effect of electron beam ionizing radiation on the physicochemical and phase separation properties of selected thermoresponsive polymers with CPT between room and body temperature. Stability of the polymers to radiation (doses 0-20 kGy) in aqueous solutions increased in the order poly(N-vinylcaprolactam) (PVCL, the least stable) ≪ poly[N-(2,2-difluoroethyl)acrylamide] (DFP) < poly(N-isopropylacrylamide) (PNIPAM) ≪ poly(2-isopropyl-2-oxazoline-co-2-n-butyl-2-oxazoline) (POX). Even low doses of β radiation (1 kGy), which are highly relevant to the storage of polymer radiotherapeutics and sterilization of biomedical systems, cause significant increase in molecular weight due to cross-linking (except for POX, where this effect is weak). In the case of PVCL irradiated with low doses, the increase in molecular weight induced an increase in the CPT of the polymer. For PNIPAM and DFP, there is strong chain hydrophilization leading to an increase in CPT. From this perspective, POX is the most suitable polymer for the construction of delivery systems that experience exposure to radiation, while PVCL is the least suitable and PNIPAM and DFP are suitable only for low radiation demands.
650    _2
$a akrylové pryskyřice $7 D000180
650    _2
$a molekulová hmotnost $7 D008970
650    12
$a nukleární lékařství $7 D009683
650    _2
$a polymery $x analýza $7 D011108
650    _2
$a teplota $7 D013696
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Černoch, Peter $u Institute of Macromolecular Chemistry, v.v.i., Academy of Sciences of the Czech Republic , Heyrovsky Sq. 2, 162 06 Prague 6, Czech Republic.
700    1_
$a Kučka, Jan $u Institute of Macromolecular Chemistry, v.v.i., Academy of Sciences of the Czech Republic , Heyrovsky Sq. 2, 162 06 Prague 6, Czech Republic.
700    1_
$a Konefal, Rafał $u Institute of Macromolecular Chemistry, v.v.i., Academy of Sciences of the Czech Republic , Heyrovsky Sq. 2, 162 06 Prague 6, Czech Republic.
700    1_
$a Štěpánek, Petr $u Institute of Macromolecular Chemistry, v.v.i., Academy of Sciences of the Czech Republic , Heyrovsky Sq. 2, 162 06 Prague 6, Czech Republic.
700    1_
$a Vetrík, Miroslav $u Institute of Macromolecular Chemistry, v.v.i., Academy of Sciences of the Czech Republic , Heyrovsky Sq. 2, 162 06 Prague 6, Czech Republic.
700    1_
$a Lodge, Timothy P $u Department of Chemistry, University of Minnesota , 207 Pleasant Street SE, Minneapolis, Minnesota 55455, United States.
700    1_
$a Hrubý, Martin $u Institute of Macromolecular Chemistry, v.v.i., Academy of Sciences of the Czech Republic , Heyrovsky Sq. 2, 162 06 Prague 6, Czech Republic.
773    0_
$w MED00006514 $t Langmuir the ACS journal of surfaces and colloids $x 1520-5827 $g Roč. 32, č. 24 (2016), s. 6115-22
856    41
$u https://pubmed.ncbi.nlm.nih.gov/27238593 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20181008 $b ABA008
991    __
$a 20201014141930 $b ABA008
999    __
$a ok $b bmc $g 1339721 $s 1031122
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2016 $b 32 $c 24 $d 6115-22 $e 20160606 $i 1520-5827 $m Langmuir $n Langmuir $x MED00006514
GRA    __
$a NV15-25781A $p MZ0
LZP    __
$a Pubmed-20181008

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...