-
Something wrong with this record ?
Analysis of new psychoactive substances in human urine by ultra-high performance supercritical fluid and liquid chromatography: Validation and comparison
L. Borovcová, V. Pauk, K. Lemr,
Language English Country Germany
Document type Journal Article
- MeSH
- Alkaloids MeSH
- Urinalysis methods MeSH
- Phenethylamines urine MeSH
- Mass Spectrometry MeSH
- Calibration MeSH
- Humans MeSH
- Limit of Detection MeSH
- Methanol urine MeSH
- Psychotropic Drugs analysis MeSH
- Reproducibility of Results MeSH
- Solvents MeSH
- Chromatography, Supercritical Fluid * MeSH
- Chromatography, High Pressure Liquid * MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
New psychoactive substances represent serious social and health problem as tens of new compounds are detected in Europe annually. They often show structural proximity or even isomerism, which complicates their analysis. Two methods based on ultra high performance supercritical fluid chromatography and ultra high performance liquid chromatography with mass spectrometric detection were validated and compared. A simple dilute-filter-and-shoot protocol utilizing propan-2-ol or methanol for supercritical fluid or liquid chromatography, respectively, was proposed to detect and quantify 15 cathinones and phenethylamines in human urine. Both methods offered fast separation (<3 min) and short total analysis time. Precision was well <15% with a few exceptions in liquid chromatography. Limits of detection in urine ranged from 0.01 to 2.3 ng/mL, except for cathinone (5 ng/mL) in supercritical fluid chromatography. Nevertheless, this technique distinguished all analytes including four pairs of isomers, while liquid chromatography was unable to resolve fluoromethcathinone regioisomers. Concerning matrix effects and recoveries, supercritical fluid chromatography produced more uniform results for different compounds and at different concentration levels. This work demonstrates the performance and reliability of supercritical fluid chromatography and corroborates its applicability as an alternative tool for analysis of new psychoactive substances in biological matrixes.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19000909
- 003
- CZ-PrNML
- 005
- 20190108130618.0
- 007
- ta
- 008
- 190107s2018 gw f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1002/jssc.201800006 $2 doi
- 035 __
- $a (PubMed)29461018
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Borovcová, Lucie $u Regional Centre of Advanced Technologies and Materials, Department of Analytical Chemistry, Faculty of Science, Palacký University in Olomouc, Olomouc, Czech Republic.
- 245 10
- $a Analysis of new psychoactive substances in human urine by ultra-high performance supercritical fluid and liquid chromatography: Validation and comparison / $c L. Borovcová, V. Pauk, K. Lemr,
- 520 9_
- $a New psychoactive substances represent serious social and health problem as tens of new compounds are detected in Europe annually. They often show structural proximity or even isomerism, which complicates their analysis. Two methods based on ultra high performance supercritical fluid chromatography and ultra high performance liquid chromatography with mass spectrometric detection were validated and compared. A simple dilute-filter-and-shoot protocol utilizing propan-2-ol or methanol for supercritical fluid or liquid chromatography, respectively, was proposed to detect and quantify 15 cathinones and phenethylamines in human urine. Both methods offered fast separation (<3 min) and short total analysis time. Precision was well <15% with a few exceptions in liquid chromatography. Limits of detection in urine ranged from 0.01 to 2.3 ng/mL, except for cathinone (5 ng/mL) in supercritical fluid chromatography. Nevertheless, this technique distinguished all analytes including four pairs of isomers, while liquid chromatography was unable to resolve fluoromethcathinone regioisomers. Concerning matrix effects and recoveries, supercritical fluid chromatography produced more uniform results for different compounds and at different concentration levels. This work demonstrates the performance and reliability of supercritical fluid chromatography and corroborates its applicability as an alternative tool for analysis of new psychoactive substances in biological matrixes.
- 650 _2
- $a alkaloidy $7 D000470
- 650 _2
- $a kalibrace $7 D002138
- 650 12
- $a vysokoúčinná kapalinová chromatografie $7 D002851
- 650 12
- $a superkritická fluidní chromatografie $7 D025924
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a limita detekce $7 D057230
- 650 _2
- $a hmotnostní spektrometrie $7 D013058
- 650 _2
- $a methanol $x moč $7 D000432
- 650 _2
- $a fenethylaminy $x moč $7 D010627
- 650 _2
- $a psychotropní léky $x analýza $7 D011619
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a rozpouštědla $7 D012997
- 650 _2
- $a analýza moči $x metody $7 D016482
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Pauk, Volodymyr $u Regional Centre of Advanced Technologies and Materials, Department of Analytical Chemistry, Faculty of Science, Palacký University in Olomouc, Olomouc, Czech Republic.
- 700 1_
- $a Lemr, Karel $u Regional Centre of Advanced Technologies and Materials, Department of Analytical Chemistry, Faculty of Science, Palacký University in Olomouc, Olomouc, Czech Republic.
- 773 0_
- $w MED00006463 $t Journal of separation science $x 1615-9314 $g Roč. 41, č. 10 (2018), s. 2288-2295
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/29461018 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20190107 $b ABA008
- 991 __
- $a 20190108130819 $b ABA008
- 999 __
- $a ok $b bmc $g 1364886 $s 1039032
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2018 $b 41 $c 10 $d 2288-2295 $e 20180312 $i 1615-9314 $m Journal of separation science $n J Sep Sci $x MED00006463
- LZP __
- $a Pubmed-20190107