-
Something wrong with this record ?
Fully automated method based on on-line molecularly imprinted polymer solid-phase extraction for determination of lovastatin in dietary supplements containing red yeast rice
L. Novosvětská, P. Chocholouš, F. Švec, H. Sklenářová,
Language English Country Germany
Document type Journal Article, Validation Study
NLK
ProQuest Central
from 2011-01-01 to 1 year ago
Medline Complete (EBSCOhost)
from 2003-01-01 to 1 year ago
Health & Medicine (ProQuest)
from 2011-01-01 to 1 year ago
- MeSH
- Anticholesteremic Agents analysis MeSH
- Biological Products analysis MeSH
- Equipment Design MeSH
- Solid Phase Extraction instrumentation methods MeSH
- Limit of Detection MeSH
- Lovastatin analysis MeSH
- Molecular Imprinting instrumentation methods MeSH
- Polymers chemistry MeSH
- Dietary Supplements analysis MeSH
- Flow Injection Analysis instrumentation methods MeSH
- Spectrophotometry, Ultraviolet instrumentation methods MeSH
- Tandem Mass Spectrometry instrumentation methods MeSH
- Chromatography, High Pressure Liquid instrumentation methods MeSH
- Publication type
- Journal Article MeSH
- Validation Study MeSH
A fully automated method for the determination of lovastatin in dietary supplements containing red yeast rice has been developed. It uses a sequential injection analysis system combined with solid-phase extraction applying highly selective molecularly imprinted polymer sorbent. A miniaturized column for on-line extraction was prepared by packing 4.5 mg of the sorbent in a 5.0 × 2.5-mm-i.d. cartridge, which was used in the flow manifold. Sequential injection analysis manifold enabled all steps of lovastatin extraction and continuous spectrophotometric detection at 240 nm. A limit of detection of 60 μg g-1, a limit of quantitation of 200 μg g-1, and a linear calibration range of 200-2000 μg g-1 were achieved. Intra-day and inter-day precision values (RSD) were ≤ 6.7% and ≤ 4.9%, respectively, and method recovery values of spiked red yeast rice extracts at 200, 1000, and 2000 μg g-1 concentration levels were 82.9, 95.2, and 87.7%. Our method was used for determination of lovastatin lactone in four dietary supplements containing red yeast rice as a natural source of lovastatin, also known as monacolin K. The extracted samples were subsequently analyzed by the reference UHPLC-MS/MS method. Statistical comparison of results (F test, t test, α = 0.05) obtained by both methods did not reveal significant difference. A substantial advantage of the new automated approach is high sample throughput thanks to the analysis time of 7.5 min, miniaturization via down-scaling the extraction column, and smaller sample and solvent consumption, as well as reduced generation of waste. Graphical abstract ᅟ.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19011981
- 003
- CZ-PrNML
- 005
- 20190405101557.0
- 007
- ta
- 008
- 190405s2019 gw f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1007/s00216-018-1554-0 $2 doi
- 035 __
- $a (PubMed)30617392
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Novosvětská, Lucie $u Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Akademika Heyrovského 1203/8, 500 05, Hradec Králové, Czech Republic.
- 245 10
- $a Fully automated method based on on-line molecularly imprinted polymer solid-phase extraction for determination of lovastatin in dietary supplements containing red yeast rice / $c L. Novosvětská, P. Chocholouš, F. Švec, H. Sklenářová,
- 520 9_
- $a A fully automated method for the determination of lovastatin in dietary supplements containing red yeast rice has been developed. It uses a sequential injection analysis system combined with solid-phase extraction applying highly selective molecularly imprinted polymer sorbent. A miniaturized column for on-line extraction was prepared by packing 4.5 mg of the sorbent in a 5.0 × 2.5-mm-i.d. cartridge, which was used in the flow manifold. Sequential injection analysis manifold enabled all steps of lovastatin extraction and continuous spectrophotometric detection at 240 nm. A limit of detection of 60 μg g-1, a limit of quantitation of 200 μg g-1, and a linear calibration range of 200-2000 μg g-1 were achieved. Intra-day and inter-day precision values (RSD) were ≤ 6.7% and ≤ 4.9%, respectively, and method recovery values of spiked red yeast rice extracts at 200, 1000, and 2000 μg g-1 concentration levels were 82.9, 95.2, and 87.7%. Our method was used for determination of lovastatin lactone in four dietary supplements containing red yeast rice as a natural source of lovastatin, also known as monacolin K. The extracted samples were subsequently analyzed by the reference UHPLC-MS/MS method. Statistical comparison of results (F test, t test, α = 0.05) obtained by both methods did not reveal significant difference. A substantial advantage of the new automated approach is high sample throughput thanks to the analysis time of 7.5 min, miniaturization via down-scaling the extraction column, and smaller sample and solvent consumption, as well as reduced generation of waste. Graphical abstract ᅟ.
- 650 _2
- $a anticholesteremika $x analýza $7 D000924
- 650 _2
- $a biologické přípravky $x analýza $7 D001688
- 650 _2
- $a vysokoúčinná kapalinová chromatografie $x přístrojové vybavení $x metody $7 D002851
- 650 _2
- $a potravní doplňky $x analýza $7 D019587
- 650 _2
- $a design vybavení $7 D004867
- 650 _2
- $a průtoková injekční analýza $x přístrojové vybavení $x metody $7 D017022
- 650 _2
- $a limita detekce $7 D057230
- 650 _2
- $a lovastatin $x analýza $7 D008148
- 650 _2
- $a molekulový imprinting $x přístrojové vybavení $x metody $7 D054802
- 650 _2
- $a polymery $x chemie $7 D011108
- 650 _2
- $a extrakce na pevné fázi $x přístrojové vybavení $x metody $7 D052616
- 650 _2
- $a spektrofotometrie ultrafialová $x přístrojové vybavení $x metody $7 D013056
- 650 _2
- $a tandemová hmotnostní spektrometrie $x přístrojové vybavení $x metody $7 D053719
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a validační studie $7 D023361
- 700 1_
- $a Chocholouš, Petr $u Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Akademika Heyrovského 1203/8, 500 05, Hradec Králové, Czech Republic.
- 700 1_
- $a Švec, František $u Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Akademika Heyrovského 1203/8, 500 05, Hradec Králové, Czech Republic.
- 700 1_
- $a Sklenářová, Hana $u Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Akademika Heyrovského 1203/8, 500 05, Hradec Králové, Czech Republic. Hana.Sklenarova@faf.cuni.cz.
- 773 0_
- $w MED00006638 $t Analytical and bioanalytical chemistry $x 1618-2650 $g Roč. 411, č. 6 (2019), s. 1219-1228
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/30617392 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20190405 $b ABA008
- 991 __
- $a 20190405101606 $b ABA008
- 999 __
- $a ok $b bmc $g 1391291 $s 1050286
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2019 $b 411 $c 6 $d 1219-1228 $e 20190107 $i 1618-2650 $m Analytical and bioanalytical chemistry $n Anal Bioanal Chem $x MED00006638
- LZP __
- $a Pubmed-20190405