Objective assessment of visual acuity: a refined model for analyzing the sweep VEP

T. Strasser, F. Nasser, H. Langrová, D. Zobor, Ł. Lisowski, D. Hillerkuss, C. Sailer, A. Kurtenbach, E. Zrenner,

. 2019 ; 138 (2) : 97-116. [pub] 20190129

Language English Country Netherlands

Document type Journal Article, Research Support, Non-U.S. Gov't

E-resources Online Full text

NLK ProQuest Central from 1997-03-01 to 1 year ago
Medline Complete (EBSCOhost) from 2011-02-01 to 1 year ago
Health & Medicine (ProQuest) from 1997-03-01 to 1 year ago

PURPOSE: The aim of this study was to develop a simple and reliable method for the objective assessment of visual acuity by optimizing the stimulus used in commercially available systems and by improving the methods of evaluation using a nonlinear function, the modified Ricker model. METHODS: Subjective visual acuity in the normal subjects was measured with Snellen targets, best-corrected, and in some cases also uncorrected and with plus lenses (+ 1 D, + 2 D, + 3 D). In patients, subjective visual acuity was measured best-corrected using the Freiburg Visual Acuity Test. Sweep VEP recordings to 11 spatial frequencies, with check sizes in logarithmically equidistant steps (0.6, 0.9, 1.4, 2.1, 3.3, 4.9, 7.3, 10.4, 18.2, 24.4, and 36.5 cpd), were obtained from 56 healthy subjects aged between 17 and 69 years (mean 42.5 ± 15.3 SD years) and 20 patients with diseases of the lens (n = 6), retina (n = 8) or optic nerve (n = 6). The results were fit by a multiple linear regression (2nd-order polynomial) or a nonlinear regression (modified Ricker model) and parameters compared (limiting spatial frequency (sflimiting) and the spatial frequency of the vertex (sfvertex) of the parabola for the 2nd-order polynomial fitting, and the maximal spatial frequency (sfmax), and the spatial frequency where the amplitude is 2 dB higher than the level of noise (sfthreshold) for the modified Ricker model. RESULTS: Recording with 11 spatial frequencies allows a more accurate determination of acuities above 1.0 logMAR. Tuning curves fitted to the results show that compared to the normal 2nd-order polynomial analysis, the modified Ricker model is able to describe closely the amplitudes of the sweep VEP in relation to the spatial frequencies of the presented checkerboards. In patients with a visual acuity better than about 0.5 (decimal), the predicted acuities based on the different parameters show a good match of the predicted visual acuities based on the models established in healthy volunteers to the subjective visual acuities. However, for lower visual acuities, both models tend to overestimate the visual acuity (up to ~ 0.4 logMAR), especially in patients suffering from AMD. CONCLUSIONS: Both models, the 2nd-order polynomial and the modified Ricker model performed equally well in the prediction of the visual acuity based on the amplitudes recorded using the sweep VEP. However, the modified Ricker model does not require the exclusion of data points from the fit, as necessary when fitting the 2nd-order polynomial model making it more reliable and robust against outliers, and, in addition, provides a measure for the noise of the recorded results.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc19027865
003      
CZ-PrNML
005      
20190823092514.0
007      
ta
008      
190813s2019 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1007/s10633-019-09672-z $2 doi
035    __
$a (PubMed)30694438
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Strasser, Torsten $u Institute for Ophthalmic Research, University of Tuebingen, Elfriede-Aulhorn-Str. 7, 72076, Tuebingen, Germany. torsten.strasser@uni-tuebingen.de.
245    10
$a Objective assessment of visual acuity: a refined model for analyzing the sweep VEP / $c T. Strasser, F. Nasser, H. Langrová, D. Zobor, Ł. Lisowski, D. Hillerkuss, C. Sailer, A. Kurtenbach, E. Zrenner,
520    9_
$a PURPOSE: The aim of this study was to develop a simple and reliable method for the objective assessment of visual acuity by optimizing the stimulus used in commercially available systems and by improving the methods of evaluation using a nonlinear function, the modified Ricker model. METHODS: Subjective visual acuity in the normal subjects was measured with Snellen targets, best-corrected, and in some cases also uncorrected and with plus lenses (+ 1 D, + 2 D, + 3 D). In patients, subjective visual acuity was measured best-corrected using the Freiburg Visual Acuity Test. Sweep VEP recordings to 11 spatial frequencies, with check sizes in logarithmically equidistant steps (0.6, 0.9, 1.4, 2.1, 3.3, 4.9, 7.3, 10.4, 18.2, 24.4, and 36.5 cpd), were obtained from 56 healthy subjects aged between 17 and 69 years (mean 42.5 ± 15.3 SD years) and 20 patients with diseases of the lens (n = 6), retina (n = 8) or optic nerve (n = 6). The results were fit by a multiple linear regression (2nd-order polynomial) or a nonlinear regression (modified Ricker model) and parameters compared (limiting spatial frequency (sflimiting) and the spatial frequency of the vertex (sfvertex) of the parabola for the 2nd-order polynomial fitting, and the maximal spatial frequency (sfmax), and the spatial frequency where the amplitude is 2 dB higher than the level of noise (sfthreshold) for the modified Ricker model. RESULTS: Recording with 11 spatial frequencies allows a more accurate determination of acuities above 1.0 logMAR. Tuning curves fitted to the results show that compared to the normal 2nd-order polynomial analysis, the modified Ricker model is able to describe closely the amplitudes of the sweep VEP in relation to the spatial frequencies of the presented checkerboards. In patients with a visual acuity better than about 0.5 (decimal), the predicted acuities based on the different parameters show a good match of the predicted visual acuities based on the models established in healthy volunteers to the subjective visual acuities. However, for lower visual acuities, both models tend to overestimate the visual acuity (up to ~ 0.4 logMAR), especially in patients suffering from AMD. CONCLUSIONS: Both models, the 2nd-order polynomial and the modified Ricker model performed equally well in the prediction of the visual acuity based on the amplitudes recorded using the sweep VEP. However, the modified Ricker model does not require the exclusion of data points from the fit, as necessary when fitting the 2nd-order polynomial model making it more reliable and robust against outliers, and, in addition, provides a measure for the noise of the recorded results.
650    _2
$a mladiství $7 D000293
650    _2
$a dospělí $7 D000328
650    _2
$a senioři $7 D000368
650    _2
$a elektroretinografie $7 D004596
650    _2
$a zrakové evokované potenciály $x fyziologie $7 D005074
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a zdraví dobrovolníci pro lékařské studie $7 D064368
650    _2
$a lidé $7 D006801
650    _2
$a nemoci oční čočky $x patofyziologie $7 D007905
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    _2
$a statistické modely $7 D015233
650    _2
$a nemoci zrakového nervu $x patofyziologie $7 D009901
650    _2
$a nemoci retiny $x patofyziologie $7 D012164
650    _2
$a zrakové testy $x metody $7 D014787
650    _2
$a zraková ostrost $x fyziologie $7 D014792
650    _2
$a mladý dospělý $7 D055815
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Nasser, Fadi $u Institute for Ophthalmic Research, University of Tuebingen, Elfriede-Aulhorn-Str. 7, 72076, Tuebingen, Germany.
700    1_
$a Langrová, Hana $u Institute for Ophthalmic Research, University of Tuebingen, Elfriede-Aulhorn-Str. 7, 72076, Tuebingen, Germany. University Eye Hospital, Hradec Králové, Czech Republic.
700    1_
$a Zobor, Ditta $u Institute for Ophthalmic Research, University of Tuebingen, Elfriede-Aulhorn-Str. 7, 72076, Tuebingen, Germany.
700    1_
$a Lisowski, Łukasz $u Institute for Ophthalmic Research, University of Tuebingen, Elfriede-Aulhorn-Str. 7, 72076, Tuebingen, Germany.
700    1_
$a Hillerkuss, Dominic $u Institute for Ophthalmic Research, University of Tuebingen, Elfriede-Aulhorn-Str. 7, 72076, Tuebingen, Germany.
700    1_
$a Sailer, Carla $u Institute for Ophthalmic Research, University of Tuebingen, Elfriede-Aulhorn-Str. 7, 72076, Tuebingen, Germany.
700    1_
$a Kurtenbach, Anne $u Institute for Ophthalmic Research, University of Tuebingen, Elfriede-Aulhorn-Str. 7, 72076, Tuebingen, Germany.
700    1_
$a Zrenner, Eberhart $u Institute for Ophthalmic Research, University of Tuebingen, Elfriede-Aulhorn-Str. 7, 72076, Tuebingen, Germany. Werner Reichardt Centre for Integrative Neuroscience (CIN), University of Tuebingen, Tuebingen, Germany.
773    0_
$w MED00010453 $t Documenta ophthalmologica. Advances in ophthalmology $x 1573-2622 $g Roč. 138, č. 2 (2019), s. 97-116
856    41
$u https://pubmed.ncbi.nlm.nih.gov/30694438 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20190813 $b ABA008
991    __
$a 20190823092728 $b ABA008
999    __
$a ok $b bmc $g 1433014 $s 1066325
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2019 $b 138 $c 2 $d 97-116 $e 20190129 $i 1573-2622 $m Documenta ophthalmologica $n Doc Ophthalmol $x MED00010453
LZP    __
$a Pubmed-20190813

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...