-
Something wrong with this record ?
Objective assessment of visual acuity: a refined model for analyzing the sweep VEP
T. Strasser, F. Nasser, H. Langrová, D. Zobor, Ł. Lisowski, D. Hillerkuss, C. Sailer, A. Kurtenbach, E. Zrenner,
Language English Country Netherlands
Document type Journal Article, Research Support, Non-U.S. Gov't
NLK
ProQuest Central
from 1997-03-01 to 1 year ago
Medline Complete (EBSCOhost)
from 2011-02-01 to 1 year ago
Health & Medicine (ProQuest)
from 1997-03-01 to 1 year ago
- MeSH
- Adult MeSH
- Electroretinography MeSH
- Middle Aged MeSH
- Humans MeSH
- Adolescent MeSH
- Young Adult MeSH
- Lens Diseases physiopathology MeSH
- Retinal Diseases physiopathology MeSH
- Optic Nerve Diseases physiopathology MeSH
- Aged MeSH
- Models, Statistical MeSH
- Healthy Volunteers MeSH
- Visual Acuity physiology MeSH
- Evoked Potentials, Visual physiology MeSH
- Vision Tests methods MeSH
- Check Tag
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Adolescent MeSH
- Young Adult MeSH
- Male MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
PURPOSE: The aim of this study was to develop a simple and reliable method for the objective assessment of visual acuity by optimizing the stimulus used in commercially available systems and by improving the methods of evaluation using a nonlinear function, the modified Ricker model. METHODS: Subjective visual acuity in the normal subjects was measured with Snellen targets, best-corrected, and in some cases also uncorrected and with plus lenses (+ 1 D, + 2 D, + 3 D). In patients, subjective visual acuity was measured best-corrected using the Freiburg Visual Acuity Test. Sweep VEP recordings to 11 spatial frequencies, with check sizes in logarithmically equidistant steps (0.6, 0.9, 1.4, 2.1, 3.3, 4.9, 7.3, 10.4, 18.2, 24.4, and 36.5 cpd), were obtained from 56 healthy subjects aged between 17 and 69 years (mean 42.5 ± 15.3 SD years) and 20 patients with diseases of the lens (n = 6), retina (n = 8) or optic nerve (n = 6). The results were fit by a multiple linear regression (2nd-order polynomial) or a nonlinear regression (modified Ricker model) and parameters compared (limiting spatial frequency (sflimiting) and the spatial frequency of the vertex (sfvertex) of the parabola for the 2nd-order polynomial fitting, and the maximal spatial frequency (sfmax), and the spatial frequency where the amplitude is 2 dB higher than the level of noise (sfthreshold) for the modified Ricker model. RESULTS: Recording with 11 spatial frequencies allows a more accurate determination of acuities above 1.0 logMAR. Tuning curves fitted to the results show that compared to the normal 2nd-order polynomial analysis, the modified Ricker model is able to describe closely the amplitudes of the sweep VEP in relation to the spatial frequencies of the presented checkerboards. In patients with a visual acuity better than about 0.5 (decimal), the predicted acuities based on the different parameters show a good match of the predicted visual acuities based on the models established in healthy volunteers to the subjective visual acuities. However, for lower visual acuities, both models tend to overestimate the visual acuity (up to ~ 0.4 logMAR), especially in patients suffering from AMD. CONCLUSIONS: Both models, the 2nd-order polynomial and the modified Ricker model performed equally well in the prediction of the visual acuity based on the amplitudes recorded using the sweep VEP. However, the modified Ricker model does not require the exclusion of data points from the fit, as necessary when fitting the 2nd-order polynomial model making it more reliable and robust against outliers, and, in addition, provides a measure for the noise of the recorded results.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19027865
- 003
- CZ-PrNML
- 005
- 20190823092514.0
- 007
- ta
- 008
- 190813s2019 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1007/s10633-019-09672-z $2 doi
- 035 __
- $a (PubMed)30694438
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Strasser, Torsten $u Institute for Ophthalmic Research, University of Tuebingen, Elfriede-Aulhorn-Str. 7, 72076, Tuebingen, Germany. torsten.strasser@uni-tuebingen.de.
- 245 10
- $a Objective assessment of visual acuity: a refined model for analyzing the sweep VEP / $c T. Strasser, F. Nasser, H. Langrová, D. Zobor, Ł. Lisowski, D. Hillerkuss, C. Sailer, A. Kurtenbach, E. Zrenner,
- 520 9_
- $a PURPOSE: The aim of this study was to develop a simple and reliable method for the objective assessment of visual acuity by optimizing the stimulus used in commercially available systems and by improving the methods of evaluation using a nonlinear function, the modified Ricker model. METHODS: Subjective visual acuity in the normal subjects was measured with Snellen targets, best-corrected, and in some cases also uncorrected and with plus lenses (+ 1 D, + 2 D, + 3 D). In patients, subjective visual acuity was measured best-corrected using the Freiburg Visual Acuity Test. Sweep VEP recordings to 11 spatial frequencies, with check sizes in logarithmically equidistant steps (0.6, 0.9, 1.4, 2.1, 3.3, 4.9, 7.3, 10.4, 18.2, 24.4, and 36.5 cpd), were obtained from 56 healthy subjects aged between 17 and 69 years (mean 42.5 ± 15.3 SD years) and 20 patients with diseases of the lens (n = 6), retina (n = 8) or optic nerve (n = 6). The results were fit by a multiple linear regression (2nd-order polynomial) or a nonlinear regression (modified Ricker model) and parameters compared (limiting spatial frequency (sflimiting) and the spatial frequency of the vertex (sfvertex) of the parabola for the 2nd-order polynomial fitting, and the maximal spatial frequency (sfmax), and the spatial frequency where the amplitude is 2 dB higher than the level of noise (sfthreshold) for the modified Ricker model. RESULTS: Recording with 11 spatial frequencies allows a more accurate determination of acuities above 1.0 logMAR. Tuning curves fitted to the results show that compared to the normal 2nd-order polynomial analysis, the modified Ricker model is able to describe closely the amplitudes of the sweep VEP in relation to the spatial frequencies of the presented checkerboards. In patients with a visual acuity better than about 0.5 (decimal), the predicted acuities based on the different parameters show a good match of the predicted visual acuities based on the models established in healthy volunteers to the subjective visual acuities. However, for lower visual acuities, both models tend to overestimate the visual acuity (up to ~ 0.4 logMAR), especially in patients suffering from AMD. CONCLUSIONS: Both models, the 2nd-order polynomial and the modified Ricker model performed equally well in the prediction of the visual acuity based on the amplitudes recorded using the sweep VEP. However, the modified Ricker model does not require the exclusion of data points from the fit, as necessary when fitting the 2nd-order polynomial model making it more reliable and robust against outliers, and, in addition, provides a measure for the noise of the recorded results.
- 650 _2
- $a mladiství $7 D000293
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a elektroretinografie $7 D004596
- 650 _2
- $a zrakové evokované potenciály $x fyziologie $7 D005074
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a zdraví dobrovolníci pro lékařské studie $7 D064368
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a nemoci oční čočky $x patofyziologie $7 D007905
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a statistické modely $7 D015233
- 650 _2
- $a nemoci zrakového nervu $x patofyziologie $7 D009901
- 650 _2
- $a nemoci retiny $x patofyziologie $7 D012164
- 650 _2
- $a zrakové testy $x metody $7 D014787
- 650 _2
- $a zraková ostrost $x fyziologie $7 D014792
- 650 _2
- $a mladý dospělý $7 D055815
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Nasser, Fadi $u Institute for Ophthalmic Research, University of Tuebingen, Elfriede-Aulhorn-Str. 7, 72076, Tuebingen, Germany.
- 700 1_
- $a Langrová, Hana $u Institute for Ophthalmic Research, University of Tuebingen, Elfriede-Aulhorn-Str. 7, 72076, Tuebingen, Germany. University Eye Hospital, Hradec Králové, Czech Republic.
- 700 1_
- $a Zobor, Ditta $u Institute for Ophthalmic Research, University of Tuebingen, Elfriede-Aulhorn-Str. 7, 72076, Tuebingen, Germany.
- 700 1_
- $a Lisowski, Łukasz $u Institute for Ophthalmic Research, University of Tuebingen, Elfriede-Aulhorn-Str. 7, 72076, Tuebingen, Germany.
- 700 1_
- $a Hillerkuss, Dominic $u Institute for Ophthalmic Research, University of Tuebingen, Elfriede-Aulhorn-Str. 7, 72076, Tuebingen, Germany.
- 700 1_
- $a Sailer, Carla $u Institute for Ophthalmic Research, University of Tuebingen, Elfriede-Aulhorn-Str. 7, 72076, Tuebingen, Germany.
- 700 1_
- $a Kurtenbach, Anne $u Institute for Ophthalmic Research, University of Tuebingen, Elfriede-Aulhorn-Str. 7, 72076, Tuebingen, Germany.
- 700 1_
- $a Zrenner, Eberhart $u Institute for Ophthalmic Research, University of Tuebingen, Elfriede-Aulhorn-Str. 7, 72076, Tuebingen, Germany. Werner Reichardt Centre for Integrative Neuroscience (CIN), University of Tuebingen, Tuebingen, Germany.
- 773 0_
- $w MED00010453 $t Documenta ophthalmologica. Advances in ophthalmology $x 1573-2622 $g Roč. 138, č. 2 (2019), s. 97-116
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/30694438 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20190813 $b ABA008
- 991 __
- $a 20190823092728 $b ABA008
- 999 __
- $a ok $b bmc $g 1433014 $s 1066325
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2019 $b 138 $c 2 $d 97-116 $e 20190129 $i 1573-2622 $m Documenta ophthalmologica $n Doc Ophthalmol $x MED00010453
- LZP __
- $a Pubmed-20190813