A computer-assisted system for handheld whole-breast ultrasonography

F. Šroubek, M. Bartoš, J. Schier, Z. Bílková, B. Zitová, J. Vydra, I. Macová, J. Daneš, L. Lambert,

. 2019 ; 14 (3) : 509-516. [pub] 20190123

Jazyk angličtina Země Německo

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc19027881

Grantová podpora
TA04011392 Technologická Agentura České Republiky
Progres Q28/LF1 Univerzita Karlova v Praze
UNCE 204065 Univerzita Karlova v Praze

PURPOSE: Breast ultrasonography (US) presents an alternative to mammography in young asymptomatic individuals and a complementary examination in screening of women with dense breasts. Handheld US is the standard-of-care, yet when used in whole-breast examination, no effort has been devoted to monitoring breast coverage and missed regions, which is the purpose of this study. METHODS: We introduce a computer-aided system assisting radiologists and US technologists in covering the whole breast with minimum alteration to the standard workflow. The proposed system comprises a standard US device, proprietary electromagnetic 3D tracking technology and software that combines US visual and tracking data to estimate a probe trajectory, total time spent in different breast segments, and a map of missed regions. A case study, which involved four radiologists (two junior and two senior) performing whole-breast ultrasound in 75 asymptomatic patients, was conducted to test the importance and relevance of the system. RESULTS: The mean process time per breast was [Formula: see text], with no statistically significant difference between the left and the right sides, and slightly longer examination time of junior radiologists. The process time density shows that central parts of the breast have better coverage compared to the periphery. Within the central part, missed regions of minimum detectable size of [Formula: see text] occur in [Formula: see text] of examinations, and non-negligible [Formula: see text] regions occur in [Formula: see text] of cases. CONCLUSION: The results of the case study indicate that missed regions are present in handheld whole-breast US, which renders the proposed system for tracking the probe position during examination a valuable tool for monitoring coverage.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc19027881
003      
CZ-PrNML
005      
20190923142815.0
007      
ta
008      
190813s2019 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1007/s11548-018-01909-7 $2 doi
035    __
$a (PubMed)30673925
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Šroubek, Filip $u Institute of Information Theory and Automation, Czech Academy of Sciences, 182 08, Prague 8, Czech Republic. sroubekf@utia.cas.cz.
245    12
$a A computer-assisted system for handheld whole-breast ultrasonography / $c F. Šroubek, M. Bartoš, J. Schier, Z. Bílková, B. Zitová, J. Vydra, I. Macová, J. Daneš, L. Lambert,
520    9_
$a PURPOSE: Breast ultrasonography (US) presents an alternative to mammography in young asymptomatic individuals and a complementary examination in screening of women with dense breasts. Handheld US is the standard-of-care, yet when used in whole-breast examination, no effort has been devoted to monitoring breast coverage and missed regions, which is the purpose of this study. METHODS: We introduce a computer-aided system assisting radiologists and US technologists in covering the whole breast with minimum alteration to the standard workflow. The proposed system comprises a standard US device, proprietary electromagnetic 3D tracking technology and software that combines US visual and tracking data to estimate a probe trajectory, total time spent in different breast segments, and a map of missed regions. A case study, which involved four radiologists (two junior and two senior) performing whole-breast ultrasound in 75 asymptomatic patients, was conducted to test the importance and relevance of the system. RESULTS: The mean process time per breast was [Formula: see text], with no statistically significant difference between the left and the right sides, and slightly longer examination time of junior radiologists. The process time density shows that central parts of the breast have better coverage compared to the periphery. Within the central part, missed regions of minimum detectable size of [Formula: see text] occur in [Formula: see text] of examinations, and non-negligible [Formula: see text] regions occur in [Formula: see text] of cases. CONCLUSION: The results of the case study indicate that missed regions are present in handheld whole-breast US, which renders the proposed system for tracking the probe position during examination a valuable tool for monitoring coverage.
650    _2
$a dospělí $7 D000328
650    _2
$a prsy $x diagnostické zobrazování $7 D001940
650    _2
$a nádory prsu $x diagnostické zobrazování $7 D001943
650    _2
$a počítačové systémy $7 D003199
650    _2
$a počítače do ruky $7 D034201
650    12
$a diagnóza počítačová $7 D003936
650    _2
$a design vybavení $7 D004867
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a lidé $7 D006801
650    _2
$a počítačové zpracování obrazu $7 D007091
650    _2
$a mamografie $x metody $7 D008327
650    _2
$a lidé středního věku $7 D008875
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a software $7 D012984
650    _2
$a ultrasonografie prsů $x metody $7 D016217
655    _2
$a časopisecké články $7 D016428
700    1_
$a Bartoš, Michal $u Institute of Information Theory and Automation, Czech Academy of Sciences, 182 08, Prague 8, Czech Republic.
700    1_
$a Schier, Jan $u Institute of Information Theory and Automation, Czech Academy of Sciences, 182 08, Prague 8, Czech Republic.
700    1_
$a Bílková, Zuzana $u Institute of Information Theory and Automation, Czech Academy of Sciences, 182 08, Prague 8, Czech Republic.
700    1_
$a Zitová, Barbara $u Institute of Information Theory and Automation, Czech Academy of Sciences, 182 08, Prague 8, Czech Republic.
700    1_
$a Vydra, Jan $u Medico Ltd, Prague, Czech Republic.
700    1_
$a Macová, Iva, $d 1989- $7 xx0239901 $u Department of Radiology, First Faculty of Medicine, Charles University and General University Hospital in Prague, 128 08, Prague 2, Czech Republic.
700    1_
$a Daneš, Jan $u Department of Radiology, First Faculty of Medicine, Charles University and General University Hospital in Prague, 128 08, Prague 2, Czech Republic.
700    1_
$a Lambert, Lukáš $u Department of Radiology, First Faculty of Medicine, Charles University and General University Hospital in Prague, 128 08, Prague 2, Czech Republic.
773    0_
$w MED00184797 $t International journal of computer assisted radiology and surgery $x 1861-6429 $g Roč. 14, č. 3 (2019), s. 509-516
856    41
$u https://pubmed.ncbi.nlm.nih.gov/30673925 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20190813 $b ABA008
991    __
$a 20190923143211 $b ABA008
999    __
$a ok $b bmc $g 1433030 $s 1066341
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2019 $b 14 $c 3 $d 509-516 $e 20190123 $i 1861-6429 $m International journal of computer assisted radiology and surgery $n Int J Comput Assist Radiol Surg $x MED00184797
GRA    __
$a TA04011392 $p Technologická Agentura České Republiky
GRA    __
$a Progres Q28/LF1 $p Univerzita Karlova v Praze
GRA    __
$a UNCE 204065 $p Univerzita Karlova v Praze
LZP    __
$a Pubmed-20190813

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...