-
Je něco špatně v tomto záznamu ?
HOW DETECTION OF PLASMID DNA FRAGMENTATION AFFECTS RADIATION STRAND BREAK YIELDS
K. Pachnerová Brabcová, L. Sihver, E. Ukraintsev, V. Štěpán, M. Davídková,
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu časopisecké články
PubMed
30534982
DOI
10.1093/rpd/ncy222
Knihovny.cz E-zdroje
- MeSH
- elektroforéza metody MeSH
- fragmentace DNA účinky záření MeSH
- lineární přenos energie MeSH
- mikroskopie atomárních sil metody MeSH
- plazmidy MeSH
- těžké ionty MeSH
- zlomy DNA účinky záření MeSH
- Publikační typ
- časopisecké články MeSH
A compromised detection of radiation-induced plasmid DNA fragments results in underestimation of calculated damage yields. Electrophoretic methods are easy and cheap, but they can only detect a part of the fragments, neglecting the shortest ones. These can be detected with atomic force microscopy, but at the expense of time and price. Both methods were used to investigate their capabilities to detect the DNA fragments induced by high-energetic heavy ions. The results were taken into account in calculations of radiation-induced yields of single and double strand breaks. It was estimated that the double strand break yield is twice as high when the fragments are at least partially detected with the agarose electrophoresis, compared to when they were completely omitted. Further increase by 13% was observed when the measured fragments were corrected for the fraction of the shortest fragments up to 300 base pairs, as detected with the atomic force microscopy. The effect of fragment detection on the single strand break yield was diminished.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19028002
- 003
- CZ-PrNML
- 005
- 20190823113347.0
- 007
- ta
- 008
- 190813s2019 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1093/rpd/ncy222 $2 doi
- 035 __
- $a (PubMed)30534982
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Pachnerová Brabcová, Kateřina $u Department of Radiation Dosimetry, Nuclear Physics Institute of the Czech Academy of Sciences, Na Truhlářce 39/64, Prague, Czech Republic.
- 245 10
- $a HOW DETECTION OF PLASMID DNA FRAGMENTATION AFFECTS RADIATION STRAND BREAK YIELDS / $c K. Pachnerová Brabcová, L. Sihver, E. Ukraintsev, V. Štěpán, M. Davídková,
- 520 9_
- $a A compromised detection of radiation-induced plasmid DNA fragments results in underestimation of calculated damage yields. Electrophoretic methods are easy and cheap, but they can only detect a part of the fragments, neglecting the shortest ones. These can be detected with atomic force microscopy, but at the expense of time and price. Both methods were used to investigate their capabilities to detect the DNA fragments induced by high-energetic heavy ions. The results were taken into account in calculations of radiation-induced yields of single and double strand breaks. It was estimated that the double strand break yield is twice as high when the fragments are at least partially detected with the agarose electrophoresis, compared to when they were completely omitted. Further increase by 13% was observed when the measured fragments were corrected for the fraction of the shortest fragments up to 300 base pairs, as detected with the atomic force microscopy. The effect of fragment detection on the single strand break yield was diminished.
- 650 _2
- $a zlomy DNA $x účinky záření $7 D053960
- 650 _2
- $a fragmentace DNA $x účinky záření $7 D053938
- 650 _2
- $a elektroforéza $x metody $7 D004586
- 650 _2
- $a těžké ionty $7 D020450
- 650 _2
- $a lineární přenos energie $7 D018499
- 650 _2
- $a mikroskopie atomárních sil $x metody $7 D018625
- 650 _2
- $a plazmidy $7 D010957
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Sihver, Lembit $u Atominstitut, Technische Universität Wien, Stadionallee 2, Wien, Austria. MedAustron, Marie-Curie-Straße 5, Wiener Neustadt, Austria.
- 700 1_
- $a Ukraintsev, Egor $u Department of Thin Films and Nanostructures, Institute of Physics of the Czech Academy of Sciences, Cukrovarnická 10/112, Prague, Czech Republic.
- 700 1_
- $a Štěpán, Václav $u Department of Radiation Dosimetry, Nuclear Physics Institute of the Czech Academy of Sciences, Na Truhlářce 39/64, Prague, Czech Republic.
- 700 1_
- $a Davídková, Marie $u Department of Radiation Dosimetry, Nuclear Physics Institute of the Czech Academy of Sciences, Na Truhlářce 39/64, Prague, Czech Republic.
- 773 0_
- $w MED00004029 $t Radiation protection dosimetry $x 1742-3406 $g Roč. 183, č. 1-2 (2019), s. 89-92
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/30534982 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20190813 $b ABA008
- 991 __
- $a 20190823113602 $b ABA008
- 999 __
- $a ok $b bmc $g 1433151 $s 1066462
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2019 $b 183 $c 1-2 $d 89-92 $e 2019May01 $i 1742-3406 $m Radiation protection dosimetry $n Radiat Prot Dosimetry $x MED00004029
- LZP __
- $a Pubmed-20190813