Something wrong with this record ?
Analysis of phosphodiesterase type 5 inhibitors as possible adulterants of botanical-based dietary supplements: extensive survey of preparations available at the Czech market
M. Jiru, M. Stranska-Zachariasova, Z. Dzuman, K. Hurkova, M. Tomaniova, R. Stepan, P. Cuhra, J. Hajslova,
Language English Country England, Great Britain
Document type Journal Article
- MeSH
- Phytochemicals analysis standards MeSH
- Phosphodiesterase 5 Inhibitors analysis MeSH
- Drug Contamination prevention & control MeSH
- Limit of Detection MeSH
- Counterfeit Drugs analysis MeSH
- Fraud prevention & control MeSH
- Dietary Supplements analysis standards MeSH
- Tandem Mass Spectrometry methods MeSH
- Chromatography, High Pressure Liquid methods MeSH
- Publication type
- Journal Article MeSH
- Geographicals
- Czech Republic MeSH
Popularity of natural-based preparations supporting the sexual potency significantly increased in recent years, which also led to the increase of illegal use of phosphodiesterase type 5 inhibitor (PDE-5) in sexual performance enhancement products. In this study, a rapid U-HPLC‒HRMS/MS method has been developed to simultaneously determine 59 PDE-5 inhibitors and their analogues. Within the development of sensitive method for analysis of 59 PDE-5 inhibitors and their analogues, both sample preparation procedure, as well as separation / detection conditions have been optimized. Extraction efficiency of particular extraction solvents, influence of different mobile phase additives on target analytes separation, as well as impact of various settings of mass analyzer on sensitivity of detection were examined. Data were collected in the 'full MS/data dependent MS/MS' acquisition mode (full MS-dd-MS/MS). Before the U-HPLC‒HRMS/MS method was used for analysis of real samples, proper validation had been conducted. The precision of the method expressed as the relative standard deviation (RSD) was ≤4.2% and ≤5.2% at spiking concentrations 5 μg/g and 0.25 μg/g, respectively. The limits of quantification were in the range 0.25 - 0.05 μg/g and the recovery ranged between 71 and 90%. The optimized method was successfully applied for analysis of 64 real samples, and 10 of them were proved to contain both registered or unregistered synthetic PDE-5 inhibitors. Additionally, the acquired U-HPLC‒HRMS/MS fingerprints were demonstrated to serve as an efficient tool for revealing of other type of possible fraud in products labeling. Retrospective mining of markers of herbs declared on dietary supplements packaging allowed to assess the trueness / untruth in the declaration of medical herbs composition.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19028042
- 003
- CZ-PrNML
- 005
- 20190823095815.0
- 007
- ta
- 008
- 190813s2019 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.jpba.2018.11.007 $2 doi
- 035 __
- $a (PubMed)30472590
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Jiru, Monika $u Department of Food Analysis and Nutrition, University of Chemistry and Technology, Prague, Technicka 3, 166 28, Prague, Czech Republic.
- 245 10
- $a Analysis of phosphodiesterase type 5 inhibitors as possible adulterants of botanical-based dietary supplements: extensive survey of preparations available at the Czech market / $c M. Jiru, M. Stranska-Zachariasova, Z. Dzuman, K. Hurkova, M. Tomaniova, R. Stepan, P. Cuhra, J. Hajslova,
- 520 9_
- $a Popularity of natural-based preparations supporting the sexual potency significantly increased in recent years, which also led to the increase of illegal use of phosphodiesterase type 5 inhibitor (PDE-5) in sexual performance enhancement products. In this study, a rapid U-HPLC‒HRMS/MS method has been developed to simultaneously determine 59 PDE-5 inhibitors and their analogues. Within the development of sensitive method for analysis of 59 PDE-5 inhibitors and their analogues, both sample preparation procedure, as well as separation / detection conditions have been optimized. Extraction efficiency of particular extraction solvents, influence of different mobile phase additives on target analytes separation, as well as impact of various settings of mass analyzer on sensitivity of detection were examined. Data were collected in the 'full MS/data dependent MS/MS' acquisition mode (full MS-dd-MS/MS). Before the U-HPLC‒HRMS/MS method was used for analysis of real samples, proper validation had been conducted. The precision of the method expressed as the relative standard deviation (RSD) was ≤4.2% and ≤5.2% at spiking concentrations 5 μg/g and 0.25 μg/g, respectively. The limits of quantification were in the range 0.25 - 0.05 μg/g and the recovery ranged between 71 and 90%. The optimized method was successfully applied for analysis of 64 real samples, and 10 of them were proved to contain both registered or unregistered synthetic PDE-5 inhibitors. Additionally, the acquired U-HPLC‒HRMS/MS fingerprints were demonstrated to serve as an efficient tool for revealing of other type of possible fraud in products labeling. Retrospective mining of markers of herbs declared on dietary supplements packaging allowed to assess the trueness / untruth in the declaration of medical herbs composition.
- 650 _2
- $a vysokoúčinná kapalinová chromatografie $x metody $7 D002851
- 650 _2
- $a padělané léky $x analýza $7 D058110
- 650 _2
- $a potravní doplňky $x analýza $x normy $7 D019587
- 650 _2
- $a kontaminace léku $x prevence a kontrola $7 D004340
- 650 _2
- $a podvod $x prevence a kontrola $7 D005607
- 650 _2
- $a limita detekce $7 D057230
- 650 _2
- $a inhibitory fosfodiesterasy 5 $x analýza $7 D058986
- 650 _2
- $a fytonutrienty $x analýza $x normy $7 D064209
- 650 _2
- $a tandemová hmotnostní spektrometrie $x metody $7 D053719
- 651 _2
- $a Česká republika $7 D018153
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Stranska-Zachariasova, Milena $u Department of Food Analysis and Nutrition, University of Chemistry and Technology, Prague, Technicka 3, 166 28, Prague, Czech Republic. Electronic address: milena.stranska@vscht.cz.
- 700 1_
- $a Dzuman, Zbynek $u Department of Food Analysis and Nutrition, University of Chemistry and Technology, Prague, Technicka 3, 166 28, Prague, Czech Republic.
- 700 1_
- $a Hurkova, Kamila $u Department of Food Analysis and Nutrition, University of Chemistry and Technology, Prague, Technicka 3, 166 28, Prague, Czech Republic.
- 700 1_
- $a Tomaniova, Monika $u Department of Food Analysis and Nutrition, University of Chemistry and Technology, Prague, Technicka 3, 166 28, Prague, Czech Republic.
- 700 1_
- $a Stepan, Radim $u Czech agriculture and food inspection authority, Inspectorate in Prague, Za Opravnou 300/6, 150 00, Prague, Czech Republic.
- 700 1_
- $a Cuhra, Petr $u Czech agriculture and food inspection authority, Inspectorate in Prague, Za Opravnou 300/6, 150 00, Prague, Czech Republic.
- 700 1_
- $a Hajslova, Jana $u Department of Food Analysis and Nutrition, University of Chemistry and Technology, Prague, Technicka 3, 166 28, Prague, Czech Republic.
- 773 0_
- $w MED00002894 $t Journal of pharmaceutical and biomedical analysis $x 1873-264X $g Roč. 164, č. - (2019), s. 713-724
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/30472590 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20190813 $b ABA008
- 991 __
- $a 20190823100030 $b ABA008
- 999 __
- $a ok $b bmc $g 1433191 $s 1066502
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2019 $b 164 $c - $d 713-724 $e 20181103 $i 1873-264X $m Journal of pharmaceutical and biomedical analysis $n J Pharm Biomed Anal $x MED00002894
- LZP __
- $a Pubmed-20190813