Modal frequency and shape curvature as a measure of implant fixation: A computer study on the acetabular cup

P. Henyš, S. Leuridan, Q. Goossens, M. Mulier, L. Pastrav, W. Desmet, JV. Sloten, K. Denis, L. Čapek,

. 2018 ; 60 (-) : 30-38. [pub] 20180727

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc19028294

Modal parameters are often investigated in order to assess the initial fixation of an implant. Most of studies are focused on the natural frequencies and frequency response function. Usually the femoral stem is tested although the acetabular cup fixation is important as well. The results of implant stability assessment are inconsistent and seem to suggest that frequency as a stability indicator is not sufficiently sensitive. In this study the sensitivity of the modal properties to changes in the bone-implant interface was investigated with the help of the finite element method (FEM). A novel fixation index based on modal shape curvature was investigated as a potential measure of the implant fixation. Modal frequencies are sensitive to interface changes in some manner, but suffer from insensitivity to local changes at bone-implant interface. The sensitivity up to 44% of natural frequencies to stiffness change due insertion steps was observed. The tested damage indicators are able to detect localized small changes in peripheral stiffness (5% stiffness reduction) with 95% confidence under the noise up to 1%. The modal shapes and their curvatures have a great potential to be a robust fixation indicator.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc19028294
003      
CZ-PrNML
005      
20190823115532.0
007      
ta
008      
190813s2018 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.medengphy.2018.07.003 $2 doi
035    __
$a (PubMed)30061064
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Henyš, Petr $u Department of Technologies and Structures, Technical University of Liberec, Studentská 1402/2, Liberec 461 17, Czechia. Electronic address: petr.henys@tul.cz.
245    10
$a Modal frequency and shape curvature as a measure of implant fixation: A computer study on the acetabular cup / $c P. Henyš, S. Leuridan, Q. Goossens, M. Mulier, L. Pastrav, W. Desmet, JV. Sloten, K. Denis, L. Čapek,
520    9_
$a Modal parameters are often investigated in order to assess the initial fixation of an implant. Most of studies are focused on the natural frequencies and frequency response function. Usually the femoral stem is tested although the acetabular cup fixation is important as well. The results of implant stability assessment are inconsistent and seem to suggest that frequency as a stability indicator is not sufficiently sensitive. In this study the sensitivity of the modal properties to changes in the bone-implant interface was investigated with the help of the finite element method (FEM). A novel fixation index based on modal shape curvature was investigated as a potential measure of the implant fixation. Modal frequencies are sensitive to interface changes in some manner, but suffer from insensitivity to local changes at bone-implant interface. The sensitivity up to 44% of natural frequencies to stiffness change due insertion steps was observed. The tested damage indicators are able to detect localized small changes in peripheral stiffness (5% stiffness reduction) with 95% confidence under the noise up to 1%. The modal shapes and their curvatures have a great potential to be a robust fixation indicator.
650    12
$a acetabulum $7 D000077
650    12
$a náhrada kyčelního kloubu $7 D019644
650    _2
$a rozhraní kost/implantát $7 D000069343
650    12
$a analýza metodou konečných prvků $7 D020342
650    _2
$a kyčelní protézy $7 D006622
655    _2
$a časopisecké články $7 D016428
700    1_
$a Leuridan, Steven $u Department of Mechanical Engineering, KU Leuven, Celestijnenlaan 300C, Leuven 3001, Belgium.
700    1_
$a Goossens, Quentin $u Department of Mechanical Engineering, KU Leuven, Celestijnenlaan 300C, Leuven 3001, Belgium.
700    1_
$a Mulier, Michiel $u Department of Mechanical Engineering, KU Leuven, Celestijnenlaan 300C, Leuven 3001, Belgium.
700    1_
$a Pastrav, Leonard $u Department of Mechanical Engineering, KU Leuven, Celestijnenlaan 300C, Leuven 3001, Belgium.
700    1_
$a Desmet, Wim $u Department of Mechanical Engineering, KU Leuven, Celestijnenlaan 300C, Leuven 3001, Belgium.
700    1_
$a Sloten, Jos Vander $u Department of Mechanical Engineering, KU Leuven, Celestijnenlaan 300C, Leuven 3001, Belgium.
700    1_
$a Denis, Kathleen $u Department of Mechanical Engineering, KU Leuven, Celestijnenlaan 300C, Leuven 3001, Belgium.
700    1_
$a Čapek, Lukáš $u Department of Technologies and Structures, Technical University of Liberec, Studentská 1402/2, Liberec 461 17, Czechia.
773    0_
$w MED00008431 $t Medical engineering & physics $x 1873-4030 $g Roč. 60, č. - (2018), s. 30-38
856    41
$u https://pubmed.ncbi.nlm.nih.gov/30061064 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20190813 $b ABA008
991    __
$a 20190823115747 $b ABA008
999    __
$a ok $b bmc $g 1433443 $s 1066754
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2018 $b 60 $c - $d 30-38 $e 20180727 $i 1873-4030 $m Medical engineering & physics $n Med Eng Phys $x MED00008431
LZP    __
$a Pubmed-20190813

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...