-
Something wrong with this record ?
Accurate simulation of transcranial ultrasound propagation for ultrasonic neuromodulation and stimulation
JL. Robertson, BT. Cox, J. Jaros, BE. Treeby,
Language English Country United States
Document type Journal Article, Research Support, Non-U.S. Gov't
PubMed
28372121
DOI
10.1121/1.4976339
Knihovny.cz E-resources
- MeSH
- Time Factors MeSH
- Humans MeSH
- Numerical Analysis, Computer-Assisted MeSH
- Computer Simulation * MeSH
- Motion MeSH
- Models, Theoretical * MeSH
- Pressure MeSH
- Ultrasonic Therapy methods MeSH
- Ultrasonic Waves * MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
Non-invasive, focal neurostimulation with ultrasound is a potentially powerful neuroscientific tool that requires effective transcranial focusing of ultrasound to develop. Time-reversal (TR) focusing using numerical simulations of transcranial ultrasound propagation can correct for the effect of the skull, but relies on accurate simulations. Here, focusing requirements for ultrasonic neurostimulation are established through a review of previously employed ultrasonic parameters, and consideration of deep brain targets. The specific limitations of finite-difference time domain (FDTD) and k-space corrected pseudospectral time domain (PSTD) schemes are tested numerically to establish the spatial points per wavelength and temporal points per period needed to achieve the desired accuracy while minimizing the computational burden. These criteria are confirmed through convergence testing of a fully simulated TR protocol using a virtual skull. The k-space PSTD scheme performed as well as, or better than, the widely used FDTD scheme across all individual error tests and in the convergence of large scale models, recommending it for use in simulated TR. Staircasing was shown to be the most serious source of error. Convergence testing indicated that higher sampling is required to achieve fine control of the pressure amplitude at the target than is needed for accurate spatial targeting.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19028798
- 003
- CZ-PrNML
- 005
- 20190819101042.0
- 007
- ta
- 008
- 190813s2017 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1121/1.4976339 $2 doi
- 035 __
- $a (PubMed)28372121
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Robertson, James L B $u Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom.
- 245 10
- $a Accurate simulation of transcranial ultrasound propagation for ultrasonic neuromodulation and stimulation / $c JL. Robertson, BT. Cox, J. Jaros, BE. Treeby,
- 520 9_
- $a Non-invasive, focal neurostimulation with ultrasound is a potentially powerful neuroscientific tool that requires effective transcranial focusing of ultrasound to develop. Time-reversal (TR) focusing using numerical simulations of transcranial ultrasound propagation can correct for the effect of the skull, but relies on accurate simulations. Here, focusing requirements for ultrasonic neurostimulation are established through a review of previously employed ultrasonic parameters, and consideration of deep brain targets. The specific limitations of finite-difference time domain (FDTD) and k-space corrected pseudospectral time domain (PSTD) schemes are tested numerically to establish the spatial points per wavelength and temporal points per period needed to achieve the desired accuracy while minimizing the computational burden. These criteria are confirmed through convergence testing of a fully simulated TR protocol using a virtual skull. The k-space PSTD scheme performed as well as, or better than, the widely used FDTD scheme across all individual error tests and in the convergence of large scale models, recommending it for use in simulated TR. Staircasing was shown to be the most serious source of error. Convergence testing indicated that higher sampling is required to achieve fine control of the pressure amplitude at the target than is needed for accurate spatial targeting.
- 650 12
- $a počítačová simulace $7 D003198
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a teoretické modely $7 D008962
- 650 _2
- $a pohyb těles $7 D009038
- 650 _2
- $a numerická analýza pomocí počítače $7 D009716
- 650 _2
- $a tlak $7 D011312
- 650 _2
- $a časové faktory $7 D013997
- 650 _2
- $a ultrazvuková terapie $x metody $7 D014464
- 650 12
- $a ultrazvukové vlny $7 D000069453
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Cox, Ben T $u Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom.
- 700 1_
- $a Jaros, J $u Faculty of Information Technology, Brno University of Technology, Brno, Czech Republic.
- 700 1_
- $a Treeby, Bradley E $u Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom.
- 773 0_
- $w MED00002959 $t The Journal of the Acoustical Society of America $x 1520-8524 $g Roč. 141, č. 3 (2017), s. 1726
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/28372121 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20190813 $b ABA008
- 991 __
- $a 20190819101316 $b ABA008
- 999 __
- $a ok $b bmc $g 1433947 $s 1067258
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2017 $b 141 $c 3 $d 1726 $e - $i 1520-8524 $m The Journal of the Acoustical Society of America $n J Acoust Soc Am $x MED00002959
- LZP __
- $a Pubmed-20190813