Stabilizace akromioklavikulární luxace tahovou cerkláží ve srovnání s jedním Kirschnerovým drátem doplněným kličkou z částečně vstřebatelného materiálu – nerandomizovaná retrospektivní studie [Comparison of tension banding and modified orthocord sling in acromioclavicular dislocation treatment - non-randomized retrospective study]

J. Trávník, J. Kovařík, T. Pavlacký, R. Veselý, T. Pink, L. Paša

. 2019 ; 86 (2) : 131-135.

Language Czech Country Czech Republic

Document type Journal Article

Digital library NLK
Source

E-resources Online

NLK Free Medical Journals from 2006

Links

PubMed 31070572

PURPOSE OF THE STUDY Acromioclavicular joint dislocations (AC) represent one of the most frequent injury to the shoulder gridle. Low grade injuries type Rockwood I-II are treated non-operatively. Whereas high grade injuries type Rockwood III-VI are usually treated operatively. At present a wide spectrum of surgical techniques is used: Bosworth screw, hook plate, pinning and tension banding, PDS-sling. In our study the pinning and tension banding technique and the modified orthocord sling technique were compared. The goal of this study was to determine whether there are any clinical and radiological differences between these two techniques. MATERIAL AND METHODS This retrospective non-randomized level 3 evidence study included 58 patients. All of them have sustained a Tossy III AC dislocation. Of the 58 patients, 31 were treated with pinning and tension banding. Modified orthocord (absorbable knitted strand) sling technique (One 2.0-2.5 mm Kirchner wire, orthocord tension banding and coraco-clavicular ligament suture) was used in 27 patients. The same regime was used in postoperative follow up. For the clinical assessment the ASES and Constant score were used. The presence of calcification, degenerative changes, clavicular dislocation were assessed during the X-ray follow-ups. RESULTS The mean treatment time was 18.7 ± 4.9 weeks in the pinning and tension band group (Group A), whereas 15.8 ± 2.8 weeks in the modified orthocord sling technique (Group B). There was a significantly shorter period of healing in Group B. There were no statistically significant differences in the K wire removal time (Group A: 12.6 ± 3.7, Group B: 11.9 ± 3.2). No significant difference was observed between Group A and Group B on the ASES score (Group A: 95 ± 5.8, Group B: 98 ± 3.1) and on the Constant score (Group A: 97.7 ± 3.2, Group B: 97.9 ± 2.9). There were significant differences in both groups between the injured and non-injured shoulder on the Constant score. The mean secondary clavicular dislocation in Group A was 7.2 ± 1.8 mm in the operated shoulder and 4.8 ± 2.0 mm in the non-operated shoulder. The secondary dislocation in Group B was 7.5 ± 2.0 mm in the injured shoulder and 4.2 ± 1.2 mm in the non-injured shoulder. There was a significant difference between the injured and the non-injured shoulder in both groups. Calcification in coraco-clavicular ligament was observed in 15 (48.4%) Group A cases and in 13 (48.1%) Group B cases. Secondary AC joint arthrosis was observed in 8 (25.8%) Group A cases and in 1 (3.7%) Group B case. DISCUSSION No significant difference in clinical outcomes between both the surgical techniques was found. These results are comparable with other, recently published studies. On the other hand, we observed a significantly decreased treatment time with the modified orthocord sling technique. One, centrically inserted Kirschner wire, might better tolerate small rotation movements in the AC joint. Secondary clavicular dislocation, Kirschner wire dislocations and wound complications were similar in both groups and comparable to other, recently published studies. CONCLUSIONS Even though the tension banding and orthocord modified sling rank among the oldest and the cheapest techniques available for AC dislocation treatment, their results are comparable with modern and costly techniques. The orthocord modified sling technique has an advantage of fast and cheap material extraction in outpatient conditions. Key words: AC dislocation, acromioclavicular joint dislocation, orthocord sling, tension banding, AC disruption, acromioclavicular joint disruption.

Comparison of tension banding and modified orthocord sling in acromioclavicular dislocation treatment - non-randomized retrospective study

000      
00000naa a2200000 a 4500
001      
bmc19030798
003      
CZ-PrNML
005      
20190913131720.0
007      
ta
008      
190902s2019 xr f 000 0|cze||
009      
AR
024    7_
$2 doi $a 10.55095/achot2019/018
035    __
$a (PubMed)31070572
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a cze
044    __
$a xr
100    1_
$a Trávník, Jan $7 _AN081800 $u Klinika traumatologie, Lékařská fakulta, Masarykova univerzita, Brno; Úrazová nemocnice v Brně
245    10
$a Stabilizace akromioklavikulární luxace tahovou cerkláží ve srovnání s jedním Kirschnerovým drátem doplněným kličkou z částečně vstřebatelného materiálu – nerandomizovaná retrospektivní studie / $c J. Trávník, J. Kovařík, T. Pavlacký, R. Veselý, T. Pink, L. Paša
246    31
$a Comparison of tension banding and modified orthocord sling in acromioclavicular dislocation treatment - non-randomized retrospective study
520    9_
$a PURPOSE OF THE STUDY Acromioclavicular joint dislocations (AC) represent one of the most frequent injury to the shoulder gridle. Low grade injuries type Rockwood I-II are treated non-operatively. Whereas high grade injuries type Rockwood III-VI are usually treated operatively. At present a wide spectrum of surgical techniques is used: Bosworth screw, hook plate, pinning and tension banding, PDS-sling. In our study the pinning and tension banding technique and the modified orthocord sling technique were compared. The goal of this study was to determine whether there are any clinical and radiological differences between these two techniques. MATERIAL AND METHODS This retrospective non-randomized level 3 evidence study included 58 patients. All of them have sustained a Tossy III AC dislocation. Of the 58 patients, 31 were treated with pinning and tension banding. Modified orthocord (absorbable knitted strand) sling technique (One 2.0-2.5 mm Kirchner wire, orthocord tension banding and coraco-clavicular ligament suture) was used in 27 patients. The same regime was used in postoperative follow up. For the clinical assessment the ASES and Constant score were used. The presence of calcification, degenerative changes, clavicular dislocation were assessed during the X-ray follow-ups. RESULTS The mean treatment time was 18.7 ± 4.9 weeks in the pinning and tension band group (Group A), whereas 15.8 ± 2.8 weeks in the modified orthocord sling technique (Group B). There was a significantly shorter period of healing in Group B. There were no statistically significant differences in the K wire removal time (Group A: 12.6 ± 3.7, Group B: 11.9 ± 3.2). No significant difference was observed between Group A and Group B on the ASES score (Group A: 95 ± 5.8, Group B: 98 ± 3.1) and on the Constant score (Group A: 97.7 ± 3.2, Group B: 97.9 ± 2.9). There were significant differences in both groups between the injured and non-injured shoulder on the Constant score. The mean secondary clavicular dislocation in Group A was 7.2 ± 1.8 mm in the operated shoulder and 4.8 ± 2.0 mm in the non-operated shoulder. The secondary dislocation in Group B was 7.5 ± 2.0 mm in the injured shoulder and 4.2 ± 1.2 mm in the non-injured shoulder. There was a significant difference between the injured and the non-injured shoulder in both groups. Calcification in coraco-clavicular ligament was observed in 15 (48.4%) Group A cases and in 13 (48.1%) Group B cases. Secondary AC joint arthrosis was observed in 8 (25.8%) Group A cases and in 1 (3.7%) Group B case. DISCUSSION No significant difference in clinical outcomes between both the surgical techniques was found. These results are comparable with other, recently published studies. On the other hand, we observed a significantly decreased treatment time with the modified orthocord sling technique. One, centrically inserted Kirschner wire, might better tolerate small rotation movements in the AC joint. Secondary clavicular dislocation, Kirschner wire dislocations and wound complications were similar in both groups and comparable to other, recently published studies. CONCLUSIONS Even though the tension banding and orthocord modified sling rank among the oldest and the cheapest techniques available for AC dislocation treatment, their results are comparable with modern and costly techniques. The orthocord modified sling technique has an advantage of fast and cheap material extraction in outpatient conditions. Key words: AC dislocation, acromioclavicular joint dislocation, orthocord sling, tension banding, AC disruption, acromioclavicular joint disruption.
650    12
$a akromioklavikulární kloub $7 D000173
650    _2
$a lidé $7 D006801
650    _2
$a imobilizace $7 D007103
650    12
$a dislokace kloubu $7 D004204
650    _2
$a retrospektivní studie $7 D012189
650    12
$a luxace ramenního kloubu $x terapie $7 D012783
650    _2
$a výsledek terapie $7 D016896
655    _2
$a časopisecké články $7 D016428
700    1_
$a Kovařík, Jan, $d 1981- $7 xx0228392 $u Traumatologické klinika Fakultní nemocnice Olomouc
700    1_
$a Pavlacký, Tomáš $7 xx0238815 $u Klinika traumatologie, Lékařská fakulta, Masarykova univerzita, Brno; Úrazová nemocnice v Brně
700    1_
$a Veselý, Radek, $d 1972- $7 mzk2011673138 $u Klinika traumatologie, Lékařská fakulta, Masarykova univerzita, Brno; Úrazová nemocnice v Brně
700    1_
$a Pink, Tomáš, $d 1971- $7 xx0103364 $u Klinika traumatologie, Lékařská fakulta, Masarykova univerzita, Brno; Úrazová nemocnice v Brně
700    1_
$a Paša, Libor, $d 1959-2022 $7 xx0037097 $u Klinika traumatologie, Lékařská fakulta, Masarykova univerzita, Brno; Úrazová nemocnice v Brně
773    0_
$w MED00011021 $t Acta chirurgiae orthopaedicae et traumatologiae Čechoslovaca $x 0001-5415 $g Roč. 86, č. 2 (2019), s. 131-135
910    __
$a ABA008 $b A 8 $c 507 $y 4 $z 0
990    __
$a 20190902 $b ABA008
991    __
$a 20190912145018 $b ABA008
999    __
$a ok $b bmc $g 1442939 $s 1069287
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2019 $b 86 $c 2 $d 131-135 $i 0001-5415 $m Acta chirurgiae orthopaedicae et traumatologiae Čechoslovaca $n Acta chir. orthop. traumatol. Čechoslovaca $x MED00011021