• Je něco špatně v tomto záznamu ?

Stable-isotope dilution LC-MS/MS method for quantitative determination of microcystin conjugates with cysteine and glutathione in biotic matrices

J. Kohoutek, T. Procházková, O. Adamovský, M. Palíková, K. Hilscherová,

. 2019 ; 411 (20) : 5267-5275. [pub] 20190525

Jazyk angličtina Země Německo

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc19034542

Grantová podpora
LM2015051 Czech Ministry of Education, Youth and Sports
CZ.02.1.01/0.0/0.0/16_013/0001761 European Structural and Investment Funds

E-zdroje Online Plný text

NLK ProQuest Central od 2011-01-01 do Před 1 rokem
Medline Complete (EBSCOhost) od 2003-01-01 do Před 1 rokem
Health & Medicine (ProQuest) od 2011-01-01 do Před 1 rokem

Microcystins are cyclic peptide toxins with hepatotoxic and tumor-promoting properties, which are produced in significant quantities (up to tens of μg/L) in freshwater cyanobacterial water blooms. Several studies reported microcystin accumulation in fish with possible food transfer to humans. These compounds are further metabolized to cysteine and glutathione conjugates which can be present in tissues in significant concentrations. In this study, we focused on the development and evaluation of robust and highly sensitive SPE-LC-MS/MS method for the analysis of microcystin conjugates in fish tissue samples. For the first time, we demonstrate the use of isotopically labeled internal standards which are essential for accurate and precise determination of analytes in complex biotic matrices. LLOQs of respective microcystin conjugates (signal-to-noise ratio; S/N > 10, peak-to-peak method) ranged from 3.3 to 5.0 ng/g of tissue fresh weight (FW). The calibration was linear within a range of concentrations from 1 to 70 ng/mL for all analyzed conjugates. The precision and repeatability of the method were very good with recoveries in the range of 88.5-107.6% and relative standard deviations between 8.8 and 13.2% for all analytes. In the follow-up study, fully validated method was used for the determination of microcystin conjugate levels in common carp exposed to microcystin-containing cyanobacterial biomass under controlled conditions. Significant amounts of microcystin conjugates (up to 55 ng/g) were found in the tissues of fish after 7 weeks of exposure. Our method was shown to be robust, sensitive, selective, and suitable for the determination of trace levels of microcystin conjugates in fish tissues.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc19034542
003      
CZ-PrNML
005      
20191010100640.0
007      
ta
008      
191007s2019 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1007/s00216-019-01904-0 $2 doi
035    __
$a (PubMed)31129692
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Kohoutek, Jiří $u RECETOX, Faculty of Science, Masaryk University, Kamenice 753/5, 62500, Brno, Czech Republic. jiri.kohoutek@recetox.muni.cz.
245    10
$a Stable-isotope dilution LC-MS/MS method for quantitative determination of microcystin conjugates with cysteine and glutathione in biotic matrices / $c J. Kohoutek, T. Procházková, O. Adamovský, M. Palíková, K. Hilscherová,
520    9_
$a Microcystins are cyclic peptide toxins with hepatotoxic and tumor-promoting properties, which are produced in significant quantities (up to tens of μg/L) in freshwater cyanobacterial water blooms. Several studies reported microcystin accumulation in fish with possible food transfer to humans. These compounds are further metabolized to cysteine and glutathione conjugates which can be present in tissues in significant concentrations. In this study, we focused on the development and evaluation of robust and highly sensitive SPE-LC-MS/MS method for the analysis of microcystin conjugates in fish tissue samples. For the first time, we demonstrate the use of isotopically labeled internal standards which are essential for accurate and precise determination of analytes in complex biotic matrices. LLOQs of respective microcystin conjugates (signal-to-noise ratio; S/N > 10, peak-to-peak method) ranged from 3.3 to 5.0 ng/g of tissue fresh weight (FW). The calibration was linear within a range of concentrations from 1 to 70 ng/mL for all analyzed conjugates. The precision and repeatability of the method were very good with recoveries in the range of 88.5-107.6% and relative standard deviations between 8.8 and 13.2% for all analytes. In the follow-up study, fully validated method was used for the determination of microcystin conjugate levels in common carp exposed to microcystin-containing cyanobacterial biomass under controlled conditions. Significant amounts of microcystin conjugates (up to 55 ng/g) were found in the tissues of fish after 7 weeks of exposure. Our method was shown to be robust, sensitive, selective, and suitable for the determination of trace levels of microcystin conjugates in fish tissues.
650    _2
$a biomasa $7 D018533
650    _2
$a chromatografie kapalinová $x metody $7 D002853
650    _2
$a sinice $x chemie $7 D000458
650    _2
$a cystein $x analýza $7 D003545
650    _2
$a glutathion $x analýza $7 D005978
650    _2
$a limita detekce $7 D057230
650    _2
$a mikrocystiny $x analýza $x chemie $7 D052998
650    _2
$a radioisotopová diluční technika $7 D011865
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a tandemová hmotnostní spektrometrie $x metody $7 D053719
655    _2
$a časopisecké články $7 D016428
700    1_
$a Procházková, Tereza $u RECETOX, Faculty of Science, Masaryk University, Kamenice 753/5, 62500, Brno, Czech Republic.
700    1_
$a Adamovský, Ondřej $u RECETOX, Faculty of Science, Masaryk University, Kamenice 753/5, 62500, Brno, Czech Republic.
700    1_
$a Palíková, Miroslava $u Faculty of Veterinary Hygiene and Ecology, University of Veterinary and Pharmaceutical Sciences, Palackého 1-3, 612 42, Brno, Czech Republic. Department of Zoology, Fisheries, Hydrobiology and Apiculture, Faculty of AgriSciences, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic.
700    1_
$a Hilscherová, Klára $u RECETOX, Faculty of Science, Masaryk University, Kamenice 753/5, 62500, Brno, Czech Republic.
773    0_
$w MED00006638 $t Analytical and bioanalytical chemistry $x 1618-2650 $g Roč. 411, č. 20 (2019), s. 5267-5275
856    41
$u https://pubmed.ncbi.nlm.nih.gov/31129692 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20191007 $b ABA008
991    __
$a 20191010101059 $b ABA008
999    __
$a ok $b bmc $g 1451202 $s 1073092
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2019 $b 411 $c 20 $d 5267-5275 $e 20190525 $i 1618-2650 $m Analytical and bioanalytical chemistry $n Anal Bioanal Chem $x MED00006638