Laryngeal mask airway UniqueTM position in paediatric patients undergoing magnetic resonance imaging (MRI): prospective observational study

J. Klučka, J. Šenkyřík, J. Skotáková, R. Štoudek, M. Ťoukalková, I. Křikava, L. Mareček, T. Pavlík, A. Štouračová, P. Štourač,

. 2018 ; 18 (1) : 153. [pub] 20181024

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články, pozorovací studie, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc19034947

BACKGROUND: Laryngeal mask UNIQUE® (LMAU) is supraglottic airway device with good clinical performance and low failure rate. Little is known about the ideal position of the LMAU on the magnetic resonance imaging (MRI) and whether radiological malposition can be associated with clinical performance (audible leak) in children. The primary aim of the study was to evaluate incidence of the radiologic malposition of the LMAU according to size. The secondary outcome was the clinical performance and associated complications (1st attempt success rate, audible leak) in LMAUs in correct position vs. radiologically misplaced LMAUs. METHODS: In prospective observational study, all paediatric patients undergoing MRI of the brain under general anaesthesia with the LMAU were included (1.9.2016-16.5.2017). The radiologically correct position: LMAU in hypopharynx, proximal cuff opposite to the C1 or C2 and distance A (proximal cuff end and aditus laryngis) ≤ distance B (distal cuff end and aditus laryngis). Malposition A: LMAU outside the hypopharynx. Malposition B: proximal cuff outside C1-C2. Malposition C: distance A ≥ distance B. We measured distances on the MRI image. Malposition incidence between LMAU sizes and first attempt success rate in trainees and consultant groups was compared using Fisher exact test, difference in incidence of malpositions using McNemar test and difference in leakage according to radiological position using two-sample binomial test. RESULTS: Overall 202 paediatric patients were included. The incidence of radiologically defined malposition was 26.2% (n = 53). Laryngeal mask was successfully inserted on the 1st attempt in 91.1% (n = 184) cases. Audible leak was detected in 3.5% (n = 7) patients. The radiologically defined malposition was present in 42.9% (n = 3) cases with audible leak. The rate of associated complications was 1.5% (n = 3): laryngospasm, desaturation, cough. In 4.0% (n = 8) the LMAU was soiled from blood. Higher incidence of radiological malposition was in LMAU 1.0, 1.5 and LMAU 3, 4 compared to LMAU 2 or LMAU 2.5 (p < 0.001). CONCLUSION: Malposition was not associated with impaired clinical performance (audible leak, complications) of the LMAU or the need for alternative airway management. TRIAL REGISTRATION: Clinicaltrials.gov (NCT02940652) Registered 18 October 18 2016.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc19034947
003      
CZ-PrNML
005      
20220223091512.0
007      
ta
008      
191007s2018 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1186/s12871-018-0617-2 $2 doi
035    __
$a (PubMed)30355285
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Klučka, Jozef $u Department of Paediatric Anaesthesia and Intensive care, University Hospital Brno, Faculty of medicine, Brno, Czech Republic.
245    10
$a Laryngeal mask airway UniqueTM position in paediatric patients undergoing magnetic resonance imaging (MRI): prospective observational study / $c J. Klučka, J. Šenkyřík, J. Skotáková, R. Štoudek, M. Ťoukalková, I. Křikava, L. Mareček, T. Pavlík, A. Štouračová, P. Štourač,
520    9_
$a BACKGROUND: Laryngeal mask UNIQUE® (LMAU) is supraglottic airway device with good clinical performance and low failure rate. Little is known about the ideal position of the LMAU on the magnetic resonance imaging (MRI) and whether radiological malposition can be associated with clinical performance (audible leak) in children. The primary aim of the study was to evaluate incidence of the radiologic malposition of the LMAU according to size. The secondary outcome was the clinical performance and associated complications (1st attempt success rate, audible leak) in LMAUs in correct position vs. radiologically misplaced LMAUs. METHODS: In prospective observational study, all paediatric patients undergoing MRI of the brain under general anaesthesia with the LMAU were included (1.9.2016-16.5.2017). The radiologically correct position: LMAU in hypopharynx, proximal cuff opposite to the C1 or C2 and distance A (proximal cuff end and aditus laryngis) ≤ distance B (distal cuff end and aditus laryngis). Malposition A: LMAU outside the hypopharynx. Malposition B: proximal cuff outside C1-C2. Malposition C: distance A ≥ distance B. We measured distances on the MRI image. Malposition incidence between LMAU sizes and first attempt success rate in trainees and consultant groups was compared using Fisher exact test, difference in incidence of malpositions using McNemar test and difference in leakage according to radiological position using two-sample binomial test. RESULTS: Overall 202 paediatric patients were included. The incidence of radiologically defined malposition was 26.2% (n = 53). Laryngeal mask was successfully inserted on the 1st attempt in 91.1% (n = 184) cases. Audible leak was detected in 3.5% (n = 7) patients. The radiologically defined malposition was present in 42.9% (n = 3) cases with audible leak. The rate of associated complications was 1.5% (n = 3): laryngospasm, desaturation, cough. In 4.0% (n = 8) the LMAU was soiled from blood. Higher incidence of radiological malposition was in LMAU 1.0, 1.5 and LMAU 3, 4 compared to LMAU 2 or LMAU 2.5 (p < 0.001). CONCLUSION: Malposition was not associated with impaired clinical performance (audible leak, complications) of the LMAU or the need for alternative airway management. TRIAL REGISTRATION: Clinicaltrials.gov (NCT02940652) Registered 18 October 18 2016.
650    _2
$a mladiství $7 D000293
650    _2
$a zajištění dýchacích cest $x metody $7 D058109
650    _2
$a celková anestezie $x metody $7 D000768
650    _2
$a mozek $x diagnostické zobrazování $7 D001921
650    _2
$a dítě $7 D002648
650    _2
$a předškolní dítě $7 D002675
650    _2
$a kašel $x epidemiologie $x etiologie $7 D003371
650    _2
$a lidé $7 D006801
650    _2
$a kojenec $7 D007223
650    12
$a laryngální masky $x škodlivé účinky $7 D017214
650    _2
$a laryngismus $x epidemiologie $x etiologie $7 D007826
650    _2
$a magnetická rezonanční tomografie $x metody $7 D008279
650    _2
$a prospektivní studie $7 D011446
655    _2
$a časopisecké články $7 D016428
655    _2
$a pozorovací studie $7 D064888
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Šenkyřík, Jan $u Department of Paediatric Radiology, University Hospital Brno, Faculty of Medicine, Masaryk University, Brno, Czech Republic.
700    1_
$a Skotáková, Jarmila $u Department of Paediatric Radiology, University Hospital Brno, Faculty of Medicine, Masaryk University, Brno, Czech Republic.
700    1_
$a Štoudek, Roman $u Department of Paediatric Anaesthesia and Intensive care, University Hospital Brno, Faculty of medicine, Brno, Czech Republic.
700    1_
$a Ťoukalková, Michaela $u Department of Paediatric Anaesthesia and Intensive care, University Hospital Brno, Faculty of medicine, Brno, Czech Republic.
700    1_
$a Křikava, Ivo $u Department of Paediatric Anaesthesia and Intensive care, University Hospital Brno, Faculty of medicine, Brno, Czech Republic.
700    1_
$a Mareček, Lukáš $u Faculty of Medicine, Masaryk University Brno, Brno, Czech Republic. $7 xx0269810
700    1_
$a Pavlík, Tomáš $u Institute of Biostatistics and Analyses, Faculty of Medicine, Masaryk University Brno, Brno, Czech Republic.
700    1_
$a Štouračová, Alena $u Department of Radiology and Nuclear Medicine, Faculty of Medicine, Masaryk University and University Hospital Brno, Brno, Czech Republic.
700    1_
$a Štourač, Petr $u Department of Paediatric Anaesthesia and Intensive care, University Hospital Brno, Faculty of medicine, Brno, Czech Republic. stourac.petr@fnbrno.cz.
773    0_
$w MED00006769 $t BMC anesthesiology $x 1471-2253 $g Roč. 18, č. 1 (2018), s. 153
856    41
$u https://pubmed.ncbi.nlm.nih.gov/30355285 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20191007 $b ABA008
991    __
$a 20220223091507 $b ABA008
999    __
$a ok $b bmc $g 1451607 $s 1073497
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2018 $b 18 $c 1 $d 153 $e 20181024 $i 1471-2253 $m BMC anesthesiology $n BMC Anesthesiol $x MED00006769
LZP    __
$a Pubmed-20191007

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...