Je něco špatně v tomto záznamu ?
Laryngeal mask airway UniqueTM position in paediatric patients undergoing magnetic resonance imaging (MRI): prospective observational study
J. Klučka, J. Šenkyřík, J. Skotáková, R. Štoudek, M. Ťoukalková, I. Křikava, L. Mareček, T. Pavlík, A. Štouračová, P. Štourač,
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu časopisecké články, pozorovací studie, práce podpořená grantem
NLK
BioMedCentral
od 2001-01-12
BioMedCentral Open Access
od 2001
Directory of Open Access Journals
od 2001
Free Medical Journals
od 2001
PubMed Central
od 2001
Europe PubMed Central
od 2001
ProQuest Central
od 2009-01-01
Open Access Digital Library
od 2001-10-01
Open Access Digital Library
od 2001-01-01
Open Access Digital Library
od 2001-01-01
Health & Medicine (ProQuest)
od 2009-01-01
ROAD: Directory of Open Access Scholarly Resources
od 2001
Springer Nature OA/Free Journals
od 2001-12-01
- MeSH
- celková anestezie metody MeSH
- dítě MeSH
- kašel epidemiologie etiologie MeSH
- kojenec MeSH
- laryngální masky * škodlivé účinky MeSH
- laryngismus epidemiologie etiologie MeSH
- lidé MeSH
- magnetická rezonanční tomografie metody MeSH
- mladiství MeSH
- mozek diagnostické zobrazování MeSH
- předškolní dítě MeSH
- prospektivní studie MeSH
- zajištění dýchacích cest metody MeSH
- Check Tag
- dítě MeSH
- kojenec MeSH
- lidé MeSH
- mladiství MeSH
- předškolní dítě MeSH
- Publikační typ
- časopisecké články MeSH
- pozorovací studie MeSH
- práce podpořená grantem MeSH
BACKGROUND: Laryngeal mask UNIQUE® (LMAU) is supraglottic airway device with good clinical performance and low failure rate. Little is known about the ideal position of the LMAU on the magnetic resonance imaging (MRI) and whether radiological malposition can be associated with clinical performance (audible leak) in children. The primary aim of the study was to evaluate incidence of the radiologic malposition of the LMAU according to size. The secondary outcome was the clinical performance and associated complications (1st attempt success rate, audible leak) in LMAUs in correct position vs. radiologically misplaced LMAUs. METHODS: In prospective observational study, all paediatric patients undergoing MRI of the brain under general anaesthesia with the LMAU were included (1.9.2016-16.5.2017). The radiologically correct position: LMAU in hypopharynx, proximal cuff opposite to the C1 or C2 and distance A (proximal cuff end and aditus laryngis) ≤ distance B (distal cuff end and aditus laryngis). Malposition A: LMAU outside the hypopharynx. Malposition B: proximal cuff outside C1-C2. Malposition C: distance A ≥ distance B. We measured distances on the MRI image. Malposition incidence between LMAU sizes and first attempt success rate in trainees and consultant groups was compared using Fisher exact test, difference in incidence of malpositions using McNemar test and difference in leakage according to radiological position using two-sample binomial test. RESULTS: Overall 202 paediatric patients were included. The incidence of radiologically defined malposition was 26.2% (n = 53). Laryngeal mask was successfully inserted on the 1st attempt in 91.1% (n = 184) cases. Audible leak was detected in 3.5% (n = 7) patients. The radiologically defined malposition was present in 42.9% (n = 3) cases with audible leak. The rate of associated complications was 1.5% (n = 3): laryngospasm, desaturation, cough. In 4.0% (n = 8) the LMAU was soiled from blood. Higher incidence of radiological malposition was in LMAU 1.0, 1.5 and LMAU 3, 4 compared to LMAU 2 or LMAU 2.5 (p < 0.001). CONCLUSION: Malposition was not associated with impaired clinical performance (audible leak, complications) of the LMAU or the need for alternative airway management. TRIAL REGISTRATION: Clinicaltrials.gov (NCT02940652) Registered 18 October 18 2016.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19034947
- 003
- CZ-PrNML
- 005
- 20220223091512.0
- 007
- ta
- 008
- 191007s2018 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1186/s12871-018-0617-2 $2 doi
- 035 __
- $a (PubMed)30355285
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Klučka, Jozef $u Department of Paediatric Anaesthesia and Intensive care, University Hospital Brno, Faculty of medicine, Brno, Czech Republic.
- 245 10
- $a Laryngeal mask airway UniqueTM position in paediatric patients undergoing magnetic resonance imaging (MRI): prospective observational study / $c J. Klučka, J. Šenkyřík, J. Skotáková, R. Štoudek, M. Ťoukalková, I. Křikava, L. Mareček, T. Pavlík, A. Štouračová, P. Štourač,
- 520 9_
- $a BACKGROUND: Laryngeal mask UNIQUE® (LMAU) is supraglottic airway device with good clinical performance and low failure rate. Little is known about the ideal position of the LMAU on the magnetic resonance imaging (MRI) and whether radiological malposition can be associated with clinical performance (audible leak) in children. The primary aim of the study was to evaluate incidence of the radiologic malposition of the LMAU according to size. The secondary outcome was the clinical performance and associated complications (1st attempt success rate, audible leak) in LMAUs in correct position vs. radiologically misplaced LMAUs. METHODS: In prospective observational study, all paediatric patients undergoing MRI of the brain under general anaesthesia with the LMAU were included (1.9.2016-16.5.2017). The radiologically correct position: LMAU in hypopharynx, proximal cuff opposite to the C1 or C2 and distance A (proximal cuff end and aditus laryngis) ≤ distance B (distal cuff end and aditus laryngis). Malposition A: LMAU outside the hypopharynx. Malposition B: proximal cuff outside C1-C2. Malposition C: distance A ≥ distance B. We measured distances on the MRI image. Malposition incidence between LMAU sizes and first attempt success rate in trainees and consultant groups was compared using Fisher exact test, difference in incidence of malpositions using McNemar test and difference in leakage according to radiological position using two-sample binomial test. RESULTS: Overall 202 paediatric patients were included. The incidence of radiologically defined malposition was 26.2% (n = 53). Laryngeal mask was successfully inserted on the 1st attempt in 91.1% (n = 184) cases. Audible leak was detected in 3.5% (n = 7) patients. The radiologically defined malposition was present in 42.9% (n = 3) cases with audible leak. The rate of associated complications was 1.5% (n = 3): laryngospasm, desaturation, cough. In 4.0% (n = 8) the LMAU was soiled from blood. Higher incidence of radiological malposition was in LMAU 1.0, 1.5 and LMAU 3, 4 compared to LMAU 2 or LMAU 2.5 (p < 0.001). CONCLUSION: Malposition was not associated with impaired clinical performance (audible leak, complications) of the LMAU or the need for alternative airway management. TRIAL REGISTRATION: Clinicaltrials.gov (NCT02940652) Registered 18 October 18 2016.
- 650 _2
- $a mladiství $7 D000293
- 650 _2
- $a zajištění dýchacích cest $x metody $7 D058109
- 650 _2
- $a celková anestezie $x metody $7 D000768
- 650 _2
- $a mozek $x diagnostické zobrazování $7 D001921
- 650 _2
- $a dítě $7 D002648
- 650 _2
- $a předškolní dítě $7 D002675
- 650 _2
- $a kašel $x epidemiologie $x etiologie $7 D003371
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a kojenec $7 D007223
- 650 12
- $a laryngální masky $x škodlivé účinky $7 D017214
- 650 _2
- $a laryngismus $x epidemiologie $x etiologie $7 D007826
- 650 _2
- $a magnetická rezonanční tomografie $x metody $7 D008279
- 650 _2
- $a prospektivní studie $7 D011446
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a pozorovací studie $7 D064888
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Šenkyřík, Jan $u Department of Paediatric Radiology, University Hospital Brno, Faculty of Medicine, Masaryk University, Brno, Czech Republic.
- 700 1_
- $a Skotáková, Jarmila $u Department of Paediatric Radiology, University Hospital Brno, Faculty of Medicine, Masaryk University, Brno, Czech Republic.
- 700 1_
- $a Štoudek, Roman $u Department of Paediatric Anaesthesia and Intensive care, University Hospital Brno, Faculty of medicine, Brno, Czech Republic.
- 700 1_
- $a Ťoukalková, Michaela $u Department of Paediatric Anaesthesia and Intensive care, University Hospital Brno, Faculty of medicine, Brno, Czech Republic.
- 700 1_
- $a Křikava, Ivo $u Department of Paediatric Anaesthesia and Intensive care, University Hospital Brno, Faculty of medicine, Brno, Czech Republic.
- 700 1_
- $a Mareček, Lukáš $u Faculty of Medicine, Masaryk University Brno, Brno, Czech Republic. $7 xx0269810
- 700 1_
- $a Pavlík, Tomáš $u Institute of Biostatistics and Analyses, Faculty of Medicine, Masaryk University Brno, Brno, Czech Republic.
- 700 1_
- $a Štouračová, Alena $u Department of Radiology and Nuclear Medicine, Faculty of Medicine, Masaryk University and University Hospital Brno, Brno, Czech Republic.
- 700 1_
- $a Štourač, Petr $u Department of Paediatric Anaesthesia and Intensive care, University Hospital Brno, Faculty of medicine, Brno, Czech Republic. stourac.petr@fnbrno.cz.
- 773 0_
- $w MED00006769 $t BMC anesthesiology $x 1471-2253 $g Roč. 18, č. 1 (2018), s. 153
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/30355285 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20191007 $b ABA008
- 991 __
- $a 20220223091507 $b ABA008
- 999 __
- $a ok $b bmc $g 1451607 $s 1073497
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2018 $b 18 $c 1 $d 153 $e 20181024 $i 1471-2253 $m BMC anesthesiology $n BMC Anesthesiol $x MED00006769
- LZP __
- $a Pubmed-20191007