-
Je něco špatně v tomto záznamu ?
A Simple Method to Obtain Basic Acoustic Measures From Video Recordings as Subtitles
SP. Kumar, JG. Švec,
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články, práce podpořená grantem
NLK
ProQuest Central
od 2010-02-01 do 2022-09-30
CINAHL Plus with Full Text (EBSCOhost)
od 1997-02-01
Medline Complete (EBSCOhost)
od 1997-02-01
Nursing & Allied Health Database (ProQuest)
od 2010-02-01 do 2022-09-30
Health & Medicine (ProQuest)
od 2010-02-01 do 2022-09-30
Psychology Database (ProQuest)
od 2010-02-01 do 2022-09-30
- MeSH
- akustika řeči * MeSH
- audiovizuální záznam * MeSH
- fonace MeSH
- hlasové řasy patofyziologie MeSH
- kalibrace MeSH
- kvalita hlasu MeSH
- laryngoskopie metody MeSH
- larynx patofyziologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- měření tvorby řeči metody MeSH
- software MeSH
- tlak MeSH
- vibrace MeSH
- zvuková spektrografie metody MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Purpose: Sound pressure level (SPL) and fundamental frequency (fo) are very basic and important measures in the acoustical assessment of voice quality, and their variation influences also the vocal fold vibration characteristics. Most sophisticated laryngeal videostroboscopic systems therefore also measure and display the SPL and fo values directly over the video frames by means of a rather expensive special hardware setup. An alternative simple software-based method is presented here to obtain these measures as video subtitles. Method: The software extracts acoustic data from the video recording, calculates the SPL and fo parameters, and saves their values in a separate subtitle file. To ensure the correct SPL values, the microphone signal is calibrated beforehand with a sound level meter. Results: The new approach was tested on videokymographic recordings obtained laryngoscopically. The results of SPL and fo values calculated from the videokymographic recording, subtitles creation, and their display are presented. Conclusions: This method is useful in integrating the acoustic measures with any kind of video recordings containing audio data when inbuilt hardware means are not available. However, calibration and other technical aspects related to data acquisition and synchronization described in this article should be properly taken care of during the recording.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19035041
- 003
- CZ-PrNML
- 005
- 20191015105555.0
- 007
- ta
- 008
- 191007s2018 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1044/2018_JSLHR-S-17-0472 $2 doi
- 035 __
- $a (PubMed)30167666
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Kumar, S Pravin $u Faculty of Science, Department of Biophysics, Voice Research Lab, Palacký University, Olomouc, Czech Republic.
- 245 12
- $a A Simple Method to Obtain Basic Acoustic Measures From Video Recordings as Subtitles / $c SP. Kumar, JG. Švec,
- 520 9_
- $a Purpose: Sound pressure level (SPL) and fundamental frequency (fo) are very basic and important measures in the acoustical assessment of voice quality, and their variation influences also the vocal fold vibration characteristics. Most sophisticated laryngeal videostroboscopic systems therefore also measure and display the SPL and fo values directly over the video frames by means of a rather expensive special hardware setup. An alternative simple software-based method is presented here to obtain these measures as video subtitles. Method: The software extracts acoustic data from the video recording, calculates the SPL and fo parameters, and saves their values in a separate subtitle file. To ensure the correct SPL values, the microphone signal is calibrated beforehand with a sound level meter. Results: The new approach was tested on videokymographic recordings obtained laryngoscopically. The results of SPL and fo values calculated from the videokymographic recording, subtitles creation, and their display are presented. Conclusions: This method is useful in integrating the acoustic measures with any kind of video recordings containing audio data when inbuilt hardware means are not available. However, calibration and other technical aspects related to data acquisition and synchronization described in this article should be properly taken care of during the recording.
- 650 _2
- $a kalibrace $7 D002138
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a laryngoskopie $x metody $7 D007828
- 650 _2
- $a larynx $x patofyziologie $7 D007830
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a fonace $7 D010699
- 650 _2
- $a tlak $7 D011312
- 650 _2
- $a software $7 D012984
- 650 _2
- $a zvuková spektrografie $x metody $7 D013018
- 650 12
- $a akustika řeči $7 D013061
- 650 _2
- $a měření tvorby řeči $x metody $7 D013068
- 650 _2
- $a vibrace $7 D014732
- 650 12
- $a audiovizuální záznam $7 D014741
- 650 _2
- $a hlasové řasy $x patofyziologie $7 D014827
- 650 _2
- $a kvalita hlasu $7 D014833
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Švec, Jan G $u Faculty of Science, Department of Biophysics, Voice Research Lab, Palacký University, Olomouc, Czech Republic.
- 773 0_
- $w MED00005429 $t Journal of speech, language, and hearing research : JSLHR $x 1558-9102 $g Roč. 61, č. 9 (2018), s. 2196-2204
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/30167666 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20191007 $b ABA008
- 991 __
- $a 20191015110020 $b ABA008
- 999 __
- $a ok $b bmc $g 1451701 $s 1073591
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2018 $b 61 $c 9 $d 2196-2204 $e 20180919 $i 1558-9102 $m Journal of speech, language, and hearing research $n J Speech Lang Hear Res $x MED00005429
- LZP __
- $a Pubmed-20191007