Je něco špatně v tomto záznamu ?
Case Studies on The Use of LiveLink for MATLAB for Evaluation and Optimization of The Heat Sources in Experimental Borehole
S. Ozana, R. Hajovsky, M. Pies, R. Martinek,
Jazyk angličtina Země Švýcarsko
Typ dokumentu časopisecké články
Grantová podpora
CZ.02.1.01/0.0/0.0/16_019/0000867
European Regional Development Fund
SP2020/42
VSB-TU Ostrava
NLK
Directory of Open Access Journals
od 2001
PubMed Central
od 2003
Europe PubMed Central
od 2003
ProQuest Central
od 2001-01-01
Open Access Digital Library
od 2001-01-01
Open Access Digital Library
od 2003-01-01
Health & Medicine (ProQuest)
od 2001-01-01
ROAD: Directory of Open Access Scholarly Resources
od 2001
PubMed
32120959
DOI
10.3390/s20051297
Knihovny.cz E-zdroje
- Publikační typ
- časopisecké články MeSH
In the Czech part of the Upper Silesian Coal Basin (Moravian-Silesian region, Czech Republic), there are many deposits of endogenous combustion (e.g., localized burning soil bodies, landfills containing industrial waste, or slag rocks caused by mining processes). The Hedwig mining dump represents such an example of these sites where, besides the temperature and the concentrations of toxic gases, electric and non-electric quantities are also monitored within the frame of experimentally proposed and patented technology for heat collection (the so-called "Pershing" system). Based on these quantities, this paper deals with the determination and evaluation of negative heat sources and the optimization of the positive heat source dependent on measured temperatures within evaluation points or on a thermal profile. The optimization problem is defined based on a balance of the heat sources in the steady state while searching for a local minimum of the objective function for the heat source. From an implementation point of view, it is the interconnection of the numerical model of the heat collector in COMSOL with a user optimization algorithm in MATLAB using the LiveLink for MATLAB. The results are elaborated in five case studies based on the susceptibility testing of the numerical model by input data from the evaluation points. The tests were focused on the model behavior in terms of preprocessing for measurement data from each chamber of the heat collector and for the estimated value of temperature differences at 90% and 110% of the nominal value. It turned out that the numerical model is more sensitive to the estimates in comparison with the measured data of the chambers, and this finding does not depend on the type optimization algorithm. The validation of the model by the use of the mean-square error led to the finding of optimal value, also valid with respect to the other evaluation.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc20005095
- 003
- CZ-PrNML
- 005
- 20210317093655.0
- 007
- ta
- 008
- 200511s2020 sz f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.3390/s20051297 $2 doi
- 035 __
- $a (PubMed)32120959
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a sz
- 100 1_
- $a Ozana, Stepan $u Faculty of Electrical Engineering and Computer Science, Department of Cybernetics and Biomedical Engineering, VŠB-Technical University of Ostrava, 708 00 Ostrava-Poruba, Czech Republic.
- 245 10
- $a Case Studies on The Use of LiveLink for MATLAB for Evaluation and Optimization of The Heat Sources in Experimental Borehole / $c S. Ozana, R. Hajovsky, M. Pies, R. Martinek,
- 520 9_
- $a In the Czech part of the Upper Silesian Coal Basin (Moravian-Silesian region, Czech Republic), there are many deposits of endogenous combustion (e.g., localized burning soil bodies, landfills containing industrial waste, or slag rocks caused by mining processes). The Hedwig mining dump represents such an example of these sites where, besides the temperature and the concentrations of toxic gases, electric and non-electric quantities are also monitored within the frame of experimentally proposed and patented technology for heat collection (the so-called "Pershing" system). Based on these quantities, this paper deals with the determination and evaluation of negative heat sources and the optimization of the positive heat source dependent on measured temperatures within evaluation points or on a thermal profile. The optimization problem is defined based on a balance of the heat sources in the steady state while searching for a local minimum of the objective function for the heat source. From an implementation point of view, it is the interconnection of the numerical model of the heat collector in COMSOL with a user optimization algorithm in MATLAB using the LiveLink for MATLAB. The results are elaborated in five case studies based on the susceptibility testing of the numerical model by input data from the evaluation points. The tests were focused on the model behavior in terms of preprocessing for measurement data from each chamber of the heat collector and for the estimated value of temperature differences at 90% and 110% of the nominal value. It turned out that the numerical model is more sensitive to the estimates in comparison with the measured data of the chambers, and this finding does not depend on the type optimization algorithm. The validation of the model by the use of the mean-square error led to the finding of optimal value, also valid with respect to the other evaluation.
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Hajovsky, Radovan $u Faculty of Electrical Engineering and Computer Science, Department of Cybernetics and Biomedical Engineering, VŠB-Technical University of Ostrava, 708 00 Ostrava-Poruba, Czech Republic.
- 700 1_
- $a Pies, Martin $u Faculty of Electrical Engineering and Computer Science, Department of Cybernetics and Biomedical Engineering, VŠB-Technical University of Ostrava, 708 00 Ostrava-Poruba, Czech Republic.
- 700 1_
- $a Martinek, Radek $u Faculty of Electrical Engineering and Computer Science, Department of Cybernetics and Biomedical Engineering, VŠB-Technical University of Ostrava, 708 00 Ostrava-Poruba, Czech Republic.
- 773 0_
- $w MED00008309 $t Sensors (Basel, Switzerland) $x 1424-8220 $g Roč. 20, č. 5 (2020)
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/32120959 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20200511 $b ABA008
- 991 __
- $a 20210317093651 $b ABA008
- 999 __
- $a ind $b bmc $g 1524025 $s 1095150
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $b 20 $c 5 $e 20200227 $i 1424-8220 $m Sensors $n Sensors Basel $x MED00008309
- GRA __
- $a CZ.02.1.01/0.0/0.0/16_019/0000867 $p European Regional Development Fund
- GRA __
- $a SP2020/42 $p VSB-TU Ostrava
- LZP __
- $a Pubmed-20200511