Evaluation of all dose components in the LVR-15 reactor epithermal neutron beam using Fricke gel dosimeter layers
G. Bartesaghi, J. Burian, G. Gambarini, M. Marek, A. Negri, L. Viererbl,
Language English Country Great Britain
Document type Comparative Study, Evaluation Study, Journal Article, Research Support, Non-U.S. Gov't
- MeSH
- Nuclear Reactors statistics & numerical data MeSH
- Phantoms, Imaging statistics & numerical data MeSH
- Humans MeSH
- Monte Carlo Method MeSH
- Radiotherapy Planning, Computer-Assisted statistics & numerical data MeSH
- Swine MeSH
- Radiometry instrumentation statistics & numerical data MeSH
- Solutions MeSH
- Fast Neutrons therapeutic use MeSH
- Boron Neutron Capture Therapy statistics & numerical data MeSH
- Thermoluminescent Dosimetry statistics & numerical data MeSH
- Water MeSH
- Gelatin MeSH
- Ferrous Compounds MeSH
- Animals MeSH
- Check Tag
- Humans MeSH
- Animals MeSH
- Publication type
- Journal Article MeSH
- Evaluation Study MeSH
- Research Support, Non-U.S. Gov't MeSH
- Comparative Study MeSH
- Geographicals
- Czech Republic MeSH
Fricke gel dosimeters in the form of layers are suitable to reconstruct bidimensional distributions of the absorbed dose; in accordance with their chemical composition and applying suitably developed algorithms, they can provide dose images of the different radiation components in a BNCT field. After the description of the applied method, this work presents the results obtained at the epithermal column of the BNCT facility at the NRI in Rez (CZ). The measured dose distributions are shown in comparison with data taken by means of other dosimeters thermoluminescence dosimeters (TLDs) and with calculations carried out with the Monte Carlo code MCNP5. The agreement with the results obtained by means of the different techniques is satisfying.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc20014348
- 003
- CZ-PrNML
- 005
- 20200921152943.0
- 007
- ta
- 008
- 200918s2009 xxk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.apradiso.2009.03.049 $2 doi
- 035 __
- $a (PubMed)19380230
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Bartesaghi, G $u Department of Physics, University of Milan, via Celoria 16, 20133 Milan, Italy. giacomo.bartesaghi@unimi.it
- 245 10
- $a Evaluation of all dose components in the LVR-15 reactor epithermal neutron beam using Fricke gel dosimeter layers / $c G. Bartesaghi, J. Burian, G. Gambarini, M. Marek, A. Negri, L. Viererbl,
- 520 9_
- $a Fricke gel dosimeters in the form of layers are suitable to reconstruct bidimensional distributions of the absorbed dose; in accordance with their chemical composition and applying suitably developed algorithms, they can provide dose images of the different radiation components in a BNCT field. After the description of the applied method, this work presents the results obtained at the epithermal column of the BNCT facility at the NRI in Rez (CZ). The measured dose distributions are shown in comparison with data taken by means of other dosimeters thermoluminescence dosimeters (TLDs) and with calculations carried out with the Monte Carlo code MCNP5. The agreement with the results obtained by means of the different techniques is satisfying.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a terapie metodou neutronového záchytu (bor-10) $x statistika a číselné údaje $7 D016754
- 650 _2
- $a rychlé neutrony $x terapeutické užití $7 D005214
- 650 _2
- $a železnaté sloučeniny $7 D005296
- 650 _2
- $a želatina $7 D005780
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a metoda Monte Carlo $7 D009010
- 650 _2
- $a atomové reaktory $x statistika a číselné údaje $7 D009688
- 650 _2
- $a fantomy radiodiagnostické $x statistika a číselné údaje $7 D019047
- 650 _2
- $a radiometrie $x přístrojové vybavení $x statistika a číselné údaje $7 D011874
- 650 _2
- $a plánování radioterapie pomocí počítače $x statistika a číselné údaje $7 D011880
- 650 _2
- $a roztoky $7 D012996
- 650 _2
- $a prasata $7 D013552
- 650 _2
- $a termoluminiscenční dozimetrie $x statistika a číselné údaje $7 D013819
- 650 _2
- $a voda $7 D014867
- 651 _2
- $a Česká republika $7 D018153
- 655 _2
- $a srovnávací studie $7 D003160
- 655 _2
- $a hodnotící studie $7 D023362
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Burian, J
- 700 1_
- $a Gambarini, G
- 700 1_
- $a Marek, M
- 700 1_
- $a Negri, A
- 700 1_
- $a Viererbl, L
- 773 0_
- $w MED00000499 $t Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine $x 1872-9800 $g Roč. 67, č. 7-8 Suppl (2009), s. S199-201
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/19380230 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20200918 $b ABA008
- 991 __
- $a 20200921152942 $b ABA008
- 999 __
- $a ok $b bmc $g 1565200 $s 1104506
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2009 $b 67 $c 7-8 Suppl $d S199-201 $e 20090327 $i 1872-9800 $m Applied radiation and isotopes $n Appl Radiat Isot $x MED00000499
- LZP __
- $a Pubmed-20200918