-
Something wrong with this record ?
Evaluation of the potential of chitosan/β-1,3-glucan/hydroxyapatite material as a scaffold for living bone graft production in vitro by comparison of ADSC and BMDSC behaviour on its surface
Agata Przekora, Marta Vandrovcova, Martina Travnickova, Julia Pajorova, Martin Molitor, Grazyna Ginalska, Lucie Bacakova
Language English Country Great Britain
Grant support
NV15-33018A
MZ0
CEP Register
- MeSH
- beta-Glucans chemistry MeSH
- Biocompatible Materials chemistry MeSH
- Cell Differentiation MeSH
- Chitosan chemistry MeSH
- Focal Adhesions MeSH
- Durapatite chemistry MeSH
- Cells, Cultured MeSH
- Humans MeSH
- Mesenchymal Stem Cells cytology physiology MeSH
- Osteogenesis MeSH
- Cell Movement MeSH
- Cell Proliferation MeSH
- Bone Regeneration MeSH
- Materials Testing MeSH
- Tissue Scaffolds chemistry MeSH
- Adipose Tissue cytology MeSH
- Check Tag
- Humans MeSH
The opinion regarding the origin of adult stem cells that should be used for living bone construct generation is strongly divided in the scientific community. In this study, the potential of chitosan/β-1,3-glucan/hydroxyapatite (chit/glu/HA) material as a scaffold for bone regeneration applications was evaluated by behaviour comparison of adult stem cells derived from both origins-adipose derived mesenchymal stem cell (ADSC) tissue and bone marrow derived mesenchymal stem cells (BMDSCs). In the case of ADSC isolation, low and high negative pressures were applied during a liposuction procedure in order to determine if negative pressure settings may have an impact on subsequent cell behaviour in vitro. The obtained results demonstrated that the chit/glu/HA material is a promising candidate to be used for living bone graft production in vitro as both ADSCs and BMDSCs revealed a satisfactory proliferation and differentiation ability on its surface. Nevertheless, BMDSCs would be a better choice of adult stem cells since they were better spread, more strongly attached and showed a more superior proliferation and differentiation ability than ADSCs when cultured on the chit/glu/HA scaffold. However, if BMDSCs cannot be isolated, ADSCs may be used for bone construct production but lipoaspirate should be collected under low negative pressure (-200 mm Hg), as high negative pressure (-700 mmHg) applied during liposuction surgery may retard subsequent ADSC proliferation and type I collagen production.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc20017913
- 003
- CZ-PrNML
- 005
- 20201112092723.0
- 007
- ta
- 008
- 201111s2017 xxk f 000 0|eng||
- 009
- AR
- 024 0_
- $a 10.1088/1748-605X/aa56f9 $2 DOI
- 035 __
- $a (Pubmed)28054934
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Przekora, Agata $u Chair and Department of Biochemistry and Biotechnology, Medical University of Lublin, Chodzki 1 Street, 20-093 Lublin, Poland
- 245 10
- $a Evaluation of the potential of chitosan/β-1,3-glucan/hydroxyapatite material as a scaffold for living bone graft production in vitro by comparison of ADSC and BMDSC behaviour on its surface / $c Agata Przekora, Marta Vandrovcova, Martina Travnickova, Julia Pajorova, Martin Molitor, Grazyna Ginalska, Lucie Bacakova
- 520 9_
- $a The opinion regarding the origin of adult stem cells that should be used for living bone construct generation is strongly divided in the scientific community. In this study, the potential of chitosan/β-1,3-glucan/hydroxyapatite (chit/glu/HA) material as a scaffold for bone regeneration applications was evaluated by behaviour comparison of adult stem cells derived from both origins-adipose derived mesenchymal stem cell (ADSC) tissue and bone marrow derived mesenchymal stem cells (BMDSCs). In the case of ADSC isolation, low and high negative pressures were applied during a liposuction procedure in order to determine if negative pressure settings may have an impact on subsequent cell behaviour in vitro. The obtained results demonstrated that the chit/glu/HA material is a promising candidate to be used for living bone graft production in vitro as both ADSCs and BMDSCs revealed a satisfactory proliferation and differentiation ability on its surface. Nevertheless, BMDSCs would be a better choice of adult stem cells since they were better spread, more strongly attached and showed a more superior proliferation and differentiation ability than ADSCs when cultured on the chit/glu/HA scaffold. However, if BMDSCs cannot be isolated, ADSCs may be used for bone construct production but lipoaspirate should be collected under low negative pressure (-200 mm Hg), as high negative pressure (-700 mmHg) applied during liposuction surgery may retard subsequent ADSC proliferation and type I collagen production.
- 650 _2
- $a tuková tkáň $x cytologie $7 D000273
- 650 _2
- $a biokompatibilní materiály $x chemie $7 D001672
- 650 _2
- $a regenerace kostí $7 D001861
- 650 _2
- $a buněčná diferenciace $7 D002454
- 650 _2
- $a pohyb buněk $7 D002465
- 650 _2
- $a proliferace buněk $7 D049109
- 650 _2
- $a kultivované buňky $7 D002478
- 650 _2
- $a chitosan $x chemie $7 D048271
- 650 _2
- $a hydroxyapatit $x chemie $7 D017886
- 650 _2
- $a fokální adheze $7 D022001
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a testování materiálů $7 D008422
- 650 _2
- $a mezenchymální kmenové buňky $x cytologie $x fyziologie $7 D059630
- 650 _2
- $a osteogeneze $7 D010012
- 650 _2
- $a tkáňové podpůrné struktury $x chemie $7 D054457
- 650 _2
- $a beta-glukany $x chemie $7 D047071
- 700 1_
- $a Vandrovcová, Marta $7 _AN051206
- 700 1_
- $a Trávníčková, Martina $7 xx0232220
- 700 1_
- $a Pajorova, Julia
- 700 1_
- $a Molitor, Martin, $d 1966- $7 stk2008428884
- 700 1_
- $a Ginalska, Grazyna
- 700 1_
- $a Bačáková, Lucie, $d 1958- $7 xx0070525
- 773 0_
- $t Biomedical materials $x 1748-6041 (tištěná verze) $g Roč. 12, č. 1 (2017), s. 015030 $w MED00180190
- 910 __
- $a ABA008 $y p $z 0
- 990 __
- $a 20201111151525 $b ABA008
- 991 __
- $a 20201112092720 $b ABA008
- 999 __
- $a ok $b bmc $g 1581620 $s 1108105
- BAS __
- $a 3
- BMC __
- $a 2017 $b 12 $c 1 $d 015030 $x MED00180190 $i 1748-6041 (tištěná verze) $m Biomedical materials
- GRA __
- $a NV15-33018A $p MZ0
- LZP __
- $a 2020-lp