-
Je něco špatně v tomto záznamu ?
The histological microstructure and in vitro mechanical properties of the human female postmenopausal perineal body
P. Kochová, R. Cimrman, M. Jansová, K. Michalová, V. Kalis, T. Kubíková, Z. Tonar,
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články, práce podpořená grantem
- MeSH
- anální kanál MeSH
- biomechanika fyziologie MeSH
- elastin analýza MeSH
- hladké svalstvo anatomie a histologie MeSH
- kolagen analýza MeSH
- kosterní svaly anatomie a histologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- mrtvola MeSH
- pánevní dno anatomie a histologie fyziologie chirurgie MeSH
- perineum anatomie a histologie fyziologie chirurgie MeSH
- postmenopauza fyziologie MeSH
- prolaps pánevních orgánů patofyziologie MeSH
- pružnost fyziologie MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- tuková tkáň anatomie a histologie MeSH
- vagina MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
OBJECTIVE: The perineal body connects muscles from the pelvic floor and is critical for support of the lower part of the vagina and proper function of the anal canal. We determined mechanical parameters and volume fractions of main components of the human female postmenopausal perineal body. METHODS: The specimens were taken from 15 fresh female cadavers (age 74 ± 10, mean ± standard deviation). Seventy-five specimens from five regions of the perineal body were processed histologically to assess volume fractions of tissue components using stereological point testing grid. Fifteen specimens taken from the midline region were loaded uniaxially with 6 mm/min velocity until tissue rupture to determine Young's modulus of elasticity, ultimate stresses, and strains. RESULTS: The perineal body was composed of collagen (29%), adipose cells (27%), elastin (7%), smooth muscle (11%), and skeletal muscle (3%). The residual tissue (19%) constituted mostly peripheral nerves, lumina of blood vessels, fibroblasts, and fibrocytes. Young's modulus of elasticity at midline region was 18 kPa (median) at small and 232 kPa at large deformations, respectively. The ultimate stress was 172 kPa and the ultimate strain was 1.4. CONCLUSIONS: We determined the structural and mechanical parameters of the perineal body. The resultant data could be used as input for models simulating pelvic floor prolapse or dysfunction.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc20022955
- 003
- CZ-PrNML
- 005
- 20201214125028.0
- 007
- ta
- 008
- 201125s2019 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1097/GME.0000000000001166 $2 doi
- 035 __
- $a (PubMed)29994970
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Kochová, Petra $u European Centre of Excellence NTIS, Faculty of Applied Sciences, University of West Bohemia, Pilsen, Czech Republic.
- 245 14
- $a The histological microstructure and in vitro mechanical properties of the human female postmenopausal perineal body / $c P. Kochová, R. Cimrman, M. Jansová, K. Michalová, V. Kalis, T. Kubíková, Z. Tonar,
- 520 9_
- $a OBJECTIVE: The perineal body connects muscles from the pelvic floor and is critical for support of the lower part of the vagina and proper function of the anal canal. We determined mechanical parameters and volume fractions of main components of the human female postmenopausal perineal body. METHODS: The specimens were taken from 15 fresh female cadavers (age 74 ± 10, mean ± standard deviation). Seventy-five specimens from five regions of the perineal body were processed histologically to assess volume fractions of tissue components using stereological point testing grid. Fifteen specimens taken from the midline region were loaded uniaxially with 6 mm/min velocity until tissue rupture to determine Young's modulus of elasticity, ultimate stresses, and strains. RESULTS: The perineal body was composed of collagen (29%), adipose cells (27%), elastin (7%), smooth muscle (11%), and skeletal muscle (3%). The residual tissue (19%) constituted mostly peripheral nerves, lumina of blood vessels, fibroblasts, and fibrocytes. Young's modulus of elasticity at midline region was 18 kPa (median) at small and 232 kPa at large deformations, respectively. The ultimate stress was 172 kPa and the ultimate strain was 1.4. CONCLUSIONS: We determined the structural and mechanical parameters of the perineal body. The resultant data could be used as input for models simulating pelvic floor prolapse or dysfunction.
- 650 _2
- $a tuková tkáň $x anatomie a histologie $7 D000273
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a senioři nad 80 let $7 D000369
- 650 _2
- $a anální kanál $7 D001003
- 650 _2
- $a biomechanika $x fyziologie $7 D001696
- 650 _2
- $a mrtvola $7 D002102
- 650 _2
- $a kolagen $x analýza $7 D003094
- 650 _2
- $a pružnost $x fyziologie $7 D004548
- 650 _2
- $a elastin $x analýza $7 D004549
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a kosterní svaly $x anatomie a histologie $7 D018482
- 650 _2
- $a hladké svalstvo $x anatomie a histologie $7 D009130
- 650 _2
- $a pánevní dno $x anatomie a histologie $x fyziologie $x chirurgie $7 D017773
- 650 _2
- $a prolaps pánevních orgánů $x patofyziologie $7 D056887
- 650 _2
- $a perineum $x anatomie a histologie $x fyziologie $x chirurgie $7 D010502
- 650 _2
- $a postmenopauza $x fyziologie $7 D017698
- 650 _2
- $a vagina $7 D014621
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Cimrman, Robert $u European Centre of Excellence NTIS, Faculty of Applied Sciences, University of West Bohemia, Pilsen, Czech Republic.
- 700 1_
- $a Jansová, Magdalena $u European Centre of Excellence NTIS, Faculty of Applied Sciences, University of West Bohemia, Pilsen, Czech Republic.
- 700 1_
- $a Michalová, Květoslava $u Sikl's Department of Pathology, University Hospital, Faculty of Medicine, Charles University, Pilsen, Czech Republic.
- 700 1_
- $a Kalis, Vladimir $u Department of Obstetrics and Gynecology, University Hospital, Faculty of Medicine, Charles University, Pilsen, Czech Republic.
- 700 1_
- $a Kubíková, Tereza $u European Centre of Excellence NTIS, Faculty of Applied Sciences, University of West Bohemia, Pilsen, Czech Republic. Department of Histology and Embryology and Biomedical Centre, Faculty of Medicine in Pilsen, Charles University, Pilsen, Czech Republic.
- 700 1_
- $a Tonar, Zbyněk $u European Centre of Excellence NTIS, Faculty of Applied Sciences, University of West Bohemia, Pilsen, Czech Republic.
- 773 0_
- $w MED00008985 $t Menopause (New York, N.Y.) $x 1530-0374 $g Roč. 26, č. 1 (2019), s. 66-77
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/29994970 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20201125 $b ABA008
- 991 __
- $a 20201214125028 $b ABA008
- 999 __
- $a ok $b bmc $g 1595274 $s 1113631
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2019 $b 26 $c 1 $d 66-77 $e - $i 1530-0374 $m Menopause $n Menopause $x MED00008985
- LZP __
- $a Pubmed-20201125