-
Something wrong with this record ?
Radiation exposure of paediatric general radiography, fluoroscopy and CT procedures in the Czech Republic - pilot study
K. Chytrá, L. Novák, P. Rejtar, M. Homola, K. Daníčková, I. Červinková,
Language English Country Great Britain
Document type Journal Article
PubMed
31832648
DOI
10.1093/rpd/ncz238
Knihovny.cz E-resources
- MeSH
- Radiation Dosage MeSH
- Child MeSH
- Fluoroscopy methods MeSH
- Gastrointestinal Diseases diagnostic imaging MeSH
- Radiography, Interventional methods MeSH
- Organs at Risk radiation effects MeSH
- Humans MeSH
- Pilot Projects MeSH
- Tomography, X-Ray Computed methods MeSH
- Image Processing, Computer-Assisted methods MeSH
- Radiation Exposure analysis MeSH
- Radiation Protection MeSH
- Urologic Diseases diagnostic imaging MeSH
- Check Tag
- Child MeSH
- Humans MeSH
- Publication type
- Journal Article MeSH
- Geographicals
- Czech Republic MeSH
The pilot dose survey on paediatric general radiography, fluoroscopy and CT procedures was performed in four university hospitals. The analysis of data was focused on the radiography and CT imaging of head, chest, abdomen, pelvis and spine and fluoroscopic procedures of gastrointestinal and urinary tracts. The survey was conducted by the National Radiation Protection Institute. Two hospitals exported data from the patient dose management system, while the others collected the data manually. The methodology of diagnostic reference levels assessment was proposed and tested. Local diagnostic reference levels were calculated in terms of air kerma-area product $P_{KA}$, CT air kerma-length product $P_{KL,CT}$ and volumetric CT air kerma index $C_{VOL}$. The lack of procedure standardisation, e.g. in tube voltage setting irrespective of patient's weight, was revealed at one hospital. Dose and exposure parameters distributions with respect to patient's anatomical constitution are presented in this article. In future, this pilot study will be a base for national survey of paediatric diagnostic reference levels.
Motol University Hospital Prague Czech Republic
National Radiation Protection Institute Prague Czech Republic
University Hospital Brno Czech Republic
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc20025345
- 003
- CZ-PrNML
- 005
- 20231213114025.0
- 007
- ta
- 008
- 201125s2019 xxk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1093/rpd/ncz238 $2 doi
- 035 __
- $a (PubMed)31832648
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Chytrá, Kateřina $u National Radiation Protection Institute, Prague, Czech Republic.
- 245 10
- $a Radiation exposure of paediatric general radiography, fluoroscopy and CT procedures in the Czech Republic - pilot study / $c K. Chytrá, L. Novák, P. Rejtar, M. Homola, K. Daníčková, I. Červinková,
- 520 9_
- $a The pilot dose survey on paediatric general radiography, fluoroscopy and CT procedures was performed in four university hospitals. The analysis of data was focused on the radiography and CT imaging of head, chest, abdomen, pelvis and spine and fluoroscopic procedures of gastrointestinal and urinary tracts. The survey was conducted by the National Radiation Protection Institute. Two hospitals exported data from the patient dose management system, while the others collected the data manually. The methodology of diagnostic reference levels assessment was proposed and tested. Local diagnostic reference levels were calculated in terms of air kerma-area product $P_{KA}$, CT air kerma-length product $P_{KL,CT}$ and volumetric CT air kerma index $C_{VOL}$. The lack of procedure standardisation, e.g. in tube voltage setting irrespective of patient's weight, was revealed at one hospital. Dose and exposure parameters distributions with respect to patient's anatomical constitution are presented in this article. In future, this pilot study will be a base for national survey of paediatric diagnostic reference levels.
- 650 _2
- $a dítě $7 D002648
- 650 _2
- $a fluoroskopie $x metody $7 D005471
- 650 _2
- $a gastrointestinální nemoci $x diagnostické zobrazování $7 D005767
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a počítačové zpracování obrazu $x metody $7 D007091
- 650 _2
- $a kritické orgány $x účinky záření $7 D058958
- 650 _2
- $a pilotní projekty $7 D010865
- 650 _2
- $a dávka záření $7 D011829
- 650 _2
- $a radiační expozice $x analýza $7 D000069079
- 650 _2
- $a radiační ochrana $7 D011835
- 650 _2
- $a intervenční radiografie $x metody $7 D015641
- 650 _2
- $a počítačová rentgenová tomografie $x metody $7 D014057
- 650 _2
- $a urologické nemoci $x diagnostické zobrazování $7 D014570
- 651 _2
- $a Česká republika $7 D018153
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Novák, Leoš $u National Radiation Protection Institute, Prague, Czech Republic.
- 700 1_
- $a Rejtar, Pavel $u University Hospital Hradec Kralove, Czech Republic.
- 700 1_
- $a Homola, Martin $u University Hospital Olomouc, Czech Republic.
- 700 1_
- $a Daníčková, Kateřina $u Motol University Hospital, Prague, Czech Republic. $7 xx0311515
- 700 1_
- $a Červinková, Ivana $u University Hospital Brno, Czech Republic.
- 773 0_
- $w MED00004029 $t Radiation protection dosimetry $x 1742-3406 $g Roč. 186, č. 2-3 (2019), s. 391-396
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/31832648 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20201125 $b ABA008
- 991 __
- $a 20231213114020 $b ABA008
- 999 __
- $a ok $b bmc $g 1599490 $s 1116031
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2019 $b 186 $c 2-3 $d 391-396 $e 2019Dec31 $i 1742-3406 $m Radiation protection dosimetry $n Radiat Prot Dosimetry $x MED00004029
- LZP __
- $a Pubmed-20201125