Verification of clinical accuracy of automated non-invasive sphygmomanometers: is it appropriate to use blood pressure simulators?
Jan Havlik, Vratislav Fabián
Jazyk angličtina Země Česko
Typ dokumentu práce podpořená grantem
- MeSH
- automatizace MeSH
- lidé MeSH
- měření krevního tlaku * metody MeSH
- monitory krevního tlaku MeSH
- oscilometrie metody MeSH
- reprodukovatelnost výsledků MeSH
- sfygmomanometry MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- práce podpořená grantem MeSH
Cardiovascular diseases are the most common cause of death in developed countries. Blood measurement is an integral part of the diagnosis of these diseases. With the development of oscillometric blood pressure monitors, the question of regular monitoring of their clinical accuracy (overall error) has arisen. This paper deals with the overall accuracy of two commercial tonometers (Hartmann Digital HG 160 comfort and HuBDIC HBP–1520), using two calibrated blood pressure simulators (Fluke BP Pump 2 and Fluke ProSim). Using the Wilcoxon rank-sum test, significant differences between the simulators have been proved for all measurements—both for SBP and DBP measurements and both for Hartmann Digital HG 160 and HuBDIC HBP–1520 tonometers (p < 0.001). Therefore, without the precise knowledge of the relationship between the blood pressure monitor and the simulator used, it is not appropriate to use simulators to determine the overall error. On the other hand, the tested devices had a very good repeatability of the measurements at all presets, with both simulators. From this point of view, it is suitable to use simulators to determine the stability of measurement by a given tonometer rather than its clinical accuracy.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc20026254
- 003
- CZ-PrNML
- 005
- 20210304160922.0
- 007
- ta
- 008
- 201221s2020 xr f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.14311/CTJ.2020.1.01 $2 doi
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Havlík, Jan, $u Faculty of Electrical Engineering, Czech Technical University in Prague, Prague, Czech Republic $d 1975- $7 ntka172511
- 245 10
- $a Verification of clinical accuracy of automated non-invasive sphygmomanometers: is it appropriate to use blood pressure simulators? / $c Jan Havlik, Vratislav Fabián
- 520 9_
- $a Cardiovascular diseases are the most common cause of death in developed countries. Blood measurement is an integral part of the diagnosis of these diseases. With the development of oscillometric blood pressure monitors, the question of regular monitoring of their clinical accuracy (overall error) has arisen. This paper deals with the overall accuracy of two commercial tonometers (Hartmann Digital HG 160 comfort and HuBDIC HBP–1520), using two calibrated blood pressure simulators (Fluke BP Pump 2 and Fluke ProSim). Using the Wilcoxon rank-sum test, significant differences between the simulators have been proved for all measurements—both for SBP and DBP measurements and both for Hartmann Digital HG 160 and HuBDIC HBP–1520 tonometers (p < 0.001). Therefore, without the precise knowledge of the relationship between the blood pressure monitor and the simulator used, it is not appropriate to use simulators to determine the overall error. On the other hand, the tested devices had a very good repeatability of the measurements at all presets, with both simulators. From this point of view, it is suitable to use simulators to determine the stability of measurement by a given tonometer rather than its clinical accuracy.
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a měření krevního tlaku $x metody $7 D001795
- 650 _2
- $a oscilometrie $x metody $7 D009991
- 650 _2
- $a monitory krevního tlaku $7 D015924
- 650 _2
- $a sfygmomanometry $7 D019722
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a automatizace $7 D001331
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Fabián, Vratislav $u Faculty of Electrical Engineering, Czech Technical University in Prague, Prague, Czech Republic $7 xx0087412
- 773 0_
- $w MED00011033 $t Lékař a technika $x 0301-5491 $g Roč. 50, č. 1 (2020), s. 5-11
- 856 41
- $u https://ojs.cvut.cz/ojs/index.php/CTJ/article/view/6285/5816 $y plný text volně přístupný
- 910 __
- $a ABA008 $b B 1367 $c 1071 b $y p $z 0
- 990 __
- $a 20201221 $b ABA008
- 991 __
- $a 20210304160919 $b ABA008
- 999 __
- $a ok $b bmc $g 1604907 $s 1116942
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $b 50 $c 1 $d 5-11 $i 0301-5491 $m Lékař a technika $x MED00011033 $y 124914
- LZP __
- $c NLK109 $d 20210304 $b NLK111 $a Meditorial-20201221