Verification of clinical accuracy of automated non-invasive sphygmomanometers: is it appropriate to use blood pressure simulators?

Jan Havlik, Vratislav Fabián

. 2020 ; 50 (1) : 5-11.

Jazyk angličtina Země Česko

Typ dokumentu práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc20026254

Cardiovascular diseases are the most common cause of death in developed countries. Blood measurement is an integral part of the diagnosis of these diseases. With the development of oscillometric blood pressure monitors, the question of regular monitoring of their clinical accuracy (overall error) has arisen. This paper deals with the overall accuracy of two commercial tonometers (Hartmann Digital HG 160 comfort and HuBDIC HBP–1520), using two calibrated blood pressure simulators (Fluke BP Pump 2 and Fluke ProSim). Using the Wilcoxon rank-sum test, significant differences between the simulators have been proved for all measurements—both for SBP and DBP measurements and both for Hartmann Digital HG 160 and HuBDIC HBP–1520 tonometers (p < 0.001). Therefore, without the precise knowledge of the relationship between the blood pressure monitor and the simulator used, it is not appropriate to use simulators to determine the overall error. On the other hand, the tested devices had a very good repeatability of the measurements at all presets, with both simulators. From this point of view, it is suitable to use simulators to determine the stability of measurement by a given tonometer rather than its clinical accuracy.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc20026254
003      
CZ-PrNML
005      
20210304160922.0
007      
ta
008      
201221s2020 xr f 000 0|eng||
009      
AR
024    7_
$a 10.14311/CTJ.2020.1.01 $2 doi
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Havlík, Jan, $u Faculty of Electrical Engineering, Czech Technical University in Prague, Prague, Czech Republic $d 1975- $7 ntka172511
245    10
$a Verification of clinical accuracy of automated non-invasive sphygmomanometers: is it appropriate to use blood pressure simulators? / $c Jan Havlik, Vratislav Fabián
520    9_
$a Cardiovascular diseases are the most common cause of death in developed countries. Blood measurement is an integral part of the diagnosis of these diseases. With the development of oscillometric blood pressure monitors, the question of regular monitoring of their clinical accuracy (overall error) has arisen. This paper deals with the overall accuracy of two commercial tonometers (Hartmann Digital HG 160 comfort and HuBDIC HBP–1520), using two calibrated blood pressure simulators (Fluke BP Pump 2 and Fluke ProSim). Using the Wilcoxon rank-sum test, significant differences between the simulators have been proved for all measurements—both for SBP and DBP measurements and both for Hartmann Digital HG 160 and HuBDIC HBP–1520 tonometers (p < 0.001). Therefore, without the precise knowledge of the relationship between the blood pressure monitor and the simulator used, it is not appropriate to use simulators to determine the overall error. On the other hand, the tested devices had a very good repeatability of the measurements at all presets, with both simulators. From this point of view, it is suitable to use simulators to determine the stability of measurement by a given tonometer rather than its clinical accuracy.
650    _2
$a lidé $7 D006801
650    12
$a měření krevního tlaku $x metody $7 D001795
650    _2
$a oscilometrie $x metody $7 D009991
650    _2
$a monitory krevního tlaku $7 D015924
650    _2
$a sfygmomanometry $7 D019722
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a automatizace $7 D001331
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Fabián, Vratislav $u Faculty of Electrical Engineering, Czech Technical University in Prague, Prague, Czech Republic $7 xx0087412
773    0_
$w MED00011033 $t Lékař a technika $x 0301-5491 $g Roč. 50, č. 1 (2020), s. 5-11
856    41
$u https://ojs.cvut.cz/ojs/index.php/CTJ/article/view/6285/5816 $y plný text volně přístupný
910    __
$a ABA008 $b B 1367 $c 1071 b $y p $z 0
990    __
$a 20201221 $b ABA008
991    __
$a 20210304160919 $b ABA008
999    __
$a ok $b bmc $g 1604907 $s 1116942
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2020 $b 50 $c 1 $d 5-11 $i 0301-5491 $m Lékař a technika $x MED00011033 $y 124914
LZP    __
$c NLK109 $d 20210304 $b NLK111 $a Meditorial-20201221

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...