-
Something wrong with this record ?
Cell type specific adhesion to surfaces functionalised by amine plasma polymers
P. Černochová, L. Blahová, J. Medalová, D. Nečas, M. Michlíček, P. Kaushik, J. Přibyl, J. Bartošíková, A. Manakhov, L. Bačáková, L. Zajíčková,
Language English Country Great Britain
Document type Journal Article, Research Support, Non-U.S. Gov't
NLK
Directory of Open Access Journals
from 2011
Free Medical Journals
from 2011
Nature Open Access
from 2011-12-01
PubMed Central
from 2011
Europe PubMed Central
from 2011
ProQuest Central
from 2011-01-01
Open Access Digital Library
from 2011-01-01
Open Access Digital Library
from 2011-01-01
Health & Medicine (ProQuest)
from 2011-01-01
ROAD: Directory of Open Access Scholarly Resources
from 2011
Springer Nature OA/Free Journals
from 2011-12-01
- MeSH
- Amines chemistry MeSH
- Cell Adhesion drug effects MeSH
- Cell Line MeSH
- Humans MeSH
- Plasma Gases chemistry MeSH
- Polymers chemistry pharmacology MeSH
- Surface Properties MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
Our previously-obtained impressive results of highly increased C2C12 mouse myoblast adhesion to amine plasma polymers (PPs) motivated current detailed studies of cell resistance to trypsinization, cell proliferation, motility, and the rate of attachment carried out for fibroblasts (LF), keratinocytes (HaCaT), rat vascular smooth muscle cells (VSMC), and endothelial cells (HUVEC, HSVEC, and CPAE) on three different amine PPs. We demonstrated the striking difference in the resistance to trypsin treatment between endothelial and non-endothelial cells. The increased resistance observed for the non-endothelial cell types was accompanied by an increased rate of cellular attachment, even though spontaneous migration was comparable to the control, i.e., to the standard cultivation surface. As demonstrated on LF fibroblasts, the resistance to trypsin was similar in serum-supplemented and serum-free media, i.e., medium without cell adhesion-mediating proteins. The increased cell adhesion was also confirmed for LF cells by an independent technique, single-cell force spectroscopy. This method, as well as the cell attachment rate, proved the difference among the plasma polymers with different amounts of amine groups, but other investigated techniques could not reveal the differences in the cell behaviour on different amine PPs. Based on all the results, the increased resistance to trypsinization of C2C12, LF, HaCaT, and VSMC cells on amine PPs can be explained most probably by a non-specific cell adhesion such as electrostatic interaction between the cells and amine groups on the material surface, rather than by the receptor-mediated adhesion through serum-derived proteins adsorbed on the PPs.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc20028102
- 003
- CZ-PrNML
- 005
- 20210114153002.0
- 007
- ta
- 008
- 210105s2020 xxk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1038/s41598-020-65889-y $2 doi
- 035 __
- $a (PubMed)32518261
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Černochová, P $u Department of Experimental Biology, Faculty of Science, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic. RG Plasma Technologies, Central European Institute of Technology - CEITEC, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic.
- 245 10
- $a Cell type specific adhesion to surfaces functionalised by amine plasma polymers / $c P. Černochová, L. Blahová, J. Medalová, D. Nečas, M. Michlíček, P. Kaushik, J. Přibyl, J. Bartošíková, A. Manakhov, L. Bačáková, L. Zajíčková,
- 520 9_
- $a Our previously-obtained impressive results of highly increased C2C12 mouse myoblast adhesion to amine plasma polymers (PPs) motivated current detailed studies of cell resistance to trypsinization, cell proliferation, motility, and the rate of attachment carried out for fibroblasts (LF), keratinocytes (HaCaT), rat vascular smooth muscle cells (VSMC), and endothelial cells (HUVEC, HSVEC, and CPAE) on three different amine PPs. We demonstrated the striking difference in the resistance to trypsin treatment between endothelial and non-endothelial cells. The increased resistance observed for the non-endothelial cell types was accompanied by an increased rate of cellular attachment, even though spontaneous migration was comparable to the control, i.e., to the standard cultivation surface. As demonstrated on LF fibroblasts, the resistance to trypsin was similar in serum-supplemented and serum-free media, i.e., medium without cell adhesion-mediating proteins. The increased cell adhesion was also confirmed for LF cells by an independent technique, single-cell force spectroscopy. This method, as well as the cell attachment rate, proved the difference among the plasma polymers with different amounts of amine groups, but other investigated techniques could not reveal the differences in the cell behaviour on different amine PPs. Based on all the results, the increased resistance to trypsinization of C2C12, LF, HaCaT, and VSMC cells on amine PPs can be explained most probably by a non-specific cell adhesion such as electrostatic interaction between the cells and amine groups on the material surface, rather than by the receptor-mediated adhesion through serum-derived proteins adsorbed on the PPs.
- 650 _2
- $a aminy $x chemie $7 D000588
- 650 _2
- $a buněčná adheze $x účinky léků $7 D002448
- 650 _2
- $a buněčné linie $7 D002460
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a plazmové plyny $x chemie $7 D058626
- 650 _2
- $a polymery $x chemie $x farmakologie $7 D011108
- 650 _2
- $a povrchové vlastnosti $7 D013499
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Blahová, L $u RG Plasma Technologies, Central European Institute of Technology - CEITEC, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic.
- 700 1_
- $a Medalová, J $u Department of Experimental Biology, Faculty of Science, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic. RG Plasma Technologies, Central European Institute of Technology - CEITEC, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic.
- 700 1_
- $a Nečas, D $u RG Plasma Technologies, Central European Institute of Technology - CEITEC, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic. Central European Institute of Technology - CEITEC, Brno University of Technology, Purkyňova 123, Brno, 612 00, Czech Republic.
- 700 1_
- $a Michlíček, M $u RG Plasma Technologies, Central European Institute of Technology - CEITEC, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic. Department of Physical Electronics, Faculty of Science, Masaryk University, Kotlářská 2, Brno, 611 37, Czech Republic.
- 700 1_
- $a Kaushik, P $u RG Plasma Technologies, Central European Institute of Technology - CEITEC, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic. Department of Physical Electronics, Faculty of Science, Masaryk University, Kotlářská 2, Brno, 611 37, Czech Republic.
- 700 1_
- $a Přibyl, J $u Core Facility Nanobiotechnology, Central European Institute of Technology - CEITEC, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic.
- 700 1_
- $a Bartošíková, J $u Department of Experimental Biology, Faculty of Science, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic.
- 700 1_
- $a Manakhov, A $u RG Plasma Technologies, Central European Institute of Technology - CEITEC, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic. Research Institute of Clinical and Experimental Lymphology- Branch of the ICG SB RAS, 2 Timakova str., 630060, Novosibirsk, Russian Federation.
- 700 1_
- $a Bačáková, L $u Institute of Physiology of the Czech Academy of Sciences, Vídeňská 1083, Prague, 142 20, Czech Republic.
- 700 1_
- $a Zajíčková, L $u RG Plasma Technologies, Central European Institute of Technology - CEITEC, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic. lenkaz@physics.muni.cz. Central European Institute of Technology - CEITEC, Brno University of Technology, Purkyňova 123, Brno, 612 00, Czech Republic. lenkaz@physics.muni.cz. Department of Physical Electronics, Faculty of Science, Masaryk University, Kotlářská 2, Brno, 611 37, Czech Republic. lenkaz@physics.muni.cz.
- 773 0_
- $w MED00182195 $t Scientific reports $x 2045-2322 $g Roč. 10, č. 1 (2020), s. 9357
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/32518261 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20210105 $b ABA008
- 991 __
- $a 20210114152959 $b ABA008
- 999 __
- $a ok $b bmc $g 1608437 $s 1119282
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $b 10 $c 1 $d 9357 $e 20200609 $i 2045-2322 $m Scientific reports $n Sci Rep $x MED00182195
- LZP __
- $a Pubmed-20210105