Je něco špatně v tomto záznamu ?
Fully automated process for histamine detection based on magnetic separation and fluorescence detection
M. Gagic, L. Nejdl, K. Xhaxhiu, N. Cernei, O. Zitka, E. Jamroz, P. Svec, L. Richtera, P. Kopel, V. Milosavljevic, V. Adam,
Jazyk angličtina Země Nizozemsko
Typ dokumentu časopisecké články
- MeSH
- fluorescence MeSH
- fluorescenční barviva chemie MeSH
- fluorescenční spektrometrie metody MeSH
- histamin analýza MeSH
- kontaminace potravin analýza MeSH
- kovové nanočástice chemie MeSH
- kvantové tečky chemie MeSH
- limita detekce MeSH
- magnetické jevy MeSH
- silany chemie MeSH
- sloučeniny kadmia chemie MeSH
- telur chemie MeSH
- titan chemie MeSH
- víno analýza MeSH
- železité sloučeniny chemie MeSH
- Publikační typ
- časopisecké články MeSH
To ensure food safety and to prevent unnecessary foodborne complications this study reports fast, fully automated process for histamine determination. This method is based on magnetic separation of histamine with magnetic particles and quantification by the fluorescence intensity change of MSA modified CdSe Quantum dots. Formation of Fe2O3 particles was followed by adsorption of TiO2 on their surface. Magnetism of developed probe enabled rapid histamine isolation prior to its fluorescence detection. Quantum dots (QDs) of approx. 3 nm were prepared via facile UV irradiation. The fluorescence intensity of CdSe QDs was enhanced upon mixing with magnetically separated histamine, in concentration-dependent manner, with a detection limit of 1.6 μM. The linear calibration curve ranged between 0.07 and 4.5 mM histamine with a low LOD and LOQ of 1.6 μM and 6 μM. The detection efficiency of the method was confirmed by ion exchange chromatography. Moreover, the specificity of the sensor was evaluated and no cross-reactivity from nontarget analytes was observed. This method was successfully applied for the direct analysis of histamine in white wine providing detection limit much lower than the histamine maximum levels established by EU regulation in food samples. The recovery rate was excellent, ranging from 84 to 100% with an RSD of less than 4.0%. The main advantage of the proposed method is full automation of the analytical procedure that reduces the time and cost of the analysis, solvent consumption and sample manipulation, enabling routine analysis of large numbers of samples for histamine and highly accurate and precise results.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc20028175
- 003
- CZ-PrNML
- 005
- 20210114153142.0
- 007
- ta
- 008
- 210105s2020 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.talanta.2020.120789 $2 doi
- 035 __
- $a (PubMed)32113552
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Gagic, Milica $u Department of Chemistry and Biochemistry, Faculty of AgriSciences, Mendel University in Brno, Zemedelska 1, CZ-613 00, Brno, Czech Republic; Central European Institute of Technology, Brno University of Technology, Purkynova 123, CZ-612 00, Brno, Czech Republic.
- 245 10
- $a Fully automated process for histamine detection based on magnetic separation and fluorescence detection / $c M. Gagic, L. Nejdl, K. Xhaxhiu, N. Cernei, O. Zitka, E. Jamroz, P. Svec, L. Richtera, P. Kopel, V. Milosavljevic, V. Adam,
- 520 9_
- $a To ensure food safety and to prevent unnecessary foodborne complications this study reports fast, fully automated process for histamine determination. This method is based on magnetic separation of histamine with magnetic particles and quantification by the fluorescence intensity change of MSA modified CdSe Quantum dots. Formation of Fe2O3 particles was followed by adsorption of TiO2 on their surface. Magnetism of developed probe enabled rapid histamine isolation prior to its fluorescence detection. Quantum dots (QDs) of approx. 3 nm were prepared via facile UV irradiation. The fluorescence intensity of CdSe QDs was enhanced upon mixing with magnetically separated histamine, in concentration-dependent manner, with a detection limit of 1.6 μM. The linear calibration curve ranged between 0.07 and 4.5 mM histamine with a low LOD and LOQ of 1.6 μM and 6 μM. The detection efficiency of the method was confirmed by ion exchange chromatography. Moreover, the specificity of the sensor was evaluated and no cross-reactivity from nontarget analytes was observed. This method was successfully applied for the direct analysis of histamine in white wine providing detection limit much lower than the histamine maximum levels established by EU regulation in food samples. The recovery rate was excellent, ranging from 84 to 100% with an RSD of less than 4.0%. The main advantage of the proposed method is full automation of the analytical procedure that reduces the time and cost of the analysis, solvent consumption and sample manipulation, enabling routine analysis of large numbers of samples for histamine and highly accurate and precise results.
- 650 _2
- $a sloučeniny kadmia $x chemie $7 D019187
- 650 _2
- $a železité sloučeniny $x chemie $7 D005290
- 650 _2
- $a fluorescence $7 D005453
- 650 _2
- $a fluorescenční barviva $x chemie $7 D005456
- 650 _2
- $a kontaminace potravin $x analýza $7 D005506
- 650 _2
- $a histamin $x analýza $7 D006632
- 650 _2
- $a limita detekce $7 D057230
- 650 _2
- $a magnetické jevy $7 D060328
- 650 _2
- $a kovové nanočástice $x chemie $7 D053768
- 650 _2
- $a kvantové tečky $x chemie $7 D045663
- 650 _2
- $a silany $x chemie $7 D012821
- 650 _2
- $a fluorescenční spektrometrie $x metody $7 D013050
- 650 _2
- $a telur $x chemie $7 D013691
- 650 _2
- $a titan $x chemie $7 D014025
- 650 _2
- $a víno $x analýza $7 D014920
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Nejdl, Lukas $u Department of Chemistry and Biochemistry, Faculty of AgriSciences, Mendel University in Brno, Zemedelska 1, CZ-613 00, Brno, Czech Republic; Central European Institute of Technology, Brno University of Technology, Purkynova 123, CZ-612 00, Brno, Czech Republic.
- 700 1_
- $a Xhaxhiu, Kledi $u Department of Chemistry, Faculty of Natural Sciences, University of Tirana, Blv. Zog. I No. 2/1, 1001, Tirana, Albania.
- 700 1_
- $a Cernei, Natalia $u Department of Chemistry and Biochemistry, Faculty of AgriSciences, Mendel University in Brno, Zemedelska 1, CZ-613 00, Brno, Czech Republic; Central European Institute of Technology, Brno University of Technology, Purkynova 123, CZ-612 00, Brno, Czech Republic.
- 700 1_
- $a Zitka, Ondrej $u Department of Chemistry and Biochemistry, Faculty of AgriSciences, Mendel University in Brno, Zemedelska 1, CZ-613 00, Brno, Czech Republic; Central European Institute of Technology, Brno University of Technology, Purkynova 123, CZ-612 00, Brno, Czech Republic.
- 700 1_
- $a Jamroz, Ewelina $u Department of Chemistry, University of Agriculture in Cracow, Balicka Street 122, PL-30-149, Cracow, Poland.
- 700 1_
- $a Svec, Pavel $u Department of Chemistry and Biochemistry, Faculty of AgriSciences, Mendel University in Brno, Zemedelska 1, CZ-613 00, Brno, Czech Republic.
- 700 1_
- $a Richtera, Lukas $u Department of Chemistry and Biochemistry, Faculty of AgriSciences, Mendel University in Brno, Zemedelska 1, CZ-613 00, Brno, Czech Republic; Central European Institute of Technology, Brno University of Technology, Purkynova 123, CZ-612 00, Brno, Czech Republic.
- 700 1_
- $a Kopel, Pavel $u Department of Inorganic Chemistry, Faculty of Science, Palacky University, 17. Listopadu 12, CZ-771 46, Olomouc, Czech Republic; Faculty of Electrical Engineering and Communication, Department of Microelectronics, Brno University of Technology, Technicka 3058/10, CZ-616 00, Brno, Czech Republic.
- 700 1_
- $a Milosavljevic, Vedran $u Department of Chemistry and Biochemistry, Faculty of AgriSciences, Mendel University in Brno, Zemedelska 1, CZ-613 00, Brno, Czech Republic; Central European Institute of Technology, Brno University of Technology, Purkynova 123, CZ-612 00, Brno, Czech Republic.
- 700 1_
- $a Adam, Vojtech $u Department of Chemistry and Biochemistry, Faculty of AgriSciences, Mendel University in Brno, Zemedelska 1, CZ-613 00, Brno, Czech Republic; Central European Institute of Technology, Brno University of Technology, Purkynova 123, CZ-612 00, Brno, Czech Republic. Electronic address: vojtech.adam@mendelu.cz.
- 773 0_
- $w MED00004484 $t Talanta $x 1873-3573 $g Roč. 212, č. - (2020), s. 120789
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/32113552 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20210105 $b ABA008
- 991 __
- $a 20210114153139 $b ABA008
- 999 __
- $a ok $b bmc $g 1608510 $s 1119355
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $b 212 $c - $d 120789 $e 20200131 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
- LZP __
- $a Pubmed-20210105