-
Je něco špatně v tomto záznamu ?
Quantification of fixed adherent cells using a strong enhancer of the fluorescence of DNA dyes
A. Ligasová, K. Koberna,
Jazyk angličtina Země Velká Británie
Typ dokumentu časopisecké články, práce podpořená grantem
NLK
Directory of Open Access Journals
od 2011
Free Medical Journals
od 2011
PubMed Central
od 2011
Europe PubMed Central
od 2011
ProQuest Central
od 2011-01-01 do 2019-12-31
Open Access Digital Library
od 2011-01-01
Open Access Digital Library
od 2011-01-01
Health & Medicine (ProQuest)
od 2011-01-01 do 2019-12-31
ROAD: Directory of Open Access Scholarly Resources
od 2011
Springer Nature OA/Free Journals
od 2011-12-01
Springer Nature - nature.com Journals - Fully Open Access
od 2011-12-01
- MeSH
- barvení a značení metody MeSH
- buněčná adheze MeSH
- buněčné linie MeSH
- buněčný cyklus MeSH
- cytofotometrie metody MeSH
- diploidie * MeSH
- DNA analýza chemie MeSH
- dodecylsíran sodný chemie MeSH
- fluorescenční barviva chemie MeSH
- HeLa buňky MeSH
- lidé MeSH
- nádorové buněčné linie MeSH
- počet buněk přístrojové vybavení metody MeSH
- replikace DNA * MeSH
- reprodukovatelnost výsledků MeSH
- viabilita buněk MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Cell quantification is widely used in basic or applied research. The current sensitive methods of cell quantification are exclusively based on the analysis of non-fixed cells and do not allow the simultaneous detection of various cellular components. A fast, sensitive and cheap method of the quantification of fixed adherent cells is described here. It is based on the incubation of DAPI- or Hoechst 33342-stained cells in a solution containing SDS. The presence of SDS results in the quick de-staining of DNA and simultaneously, in an up-to-1,000-fold increase of the fluorescence intensity of the used dyes. This increase can be attributed to the micelle formation of SDS. The method is sufficiently sensitive to reveal around 50-70 human diploid cells. It is compatible with immunocytochemical detections, the detection of DNA replication and cell cycle analysis by image cytometry. The procedure was successfully tested for the analysis of cytotoxicity. The method is suitable for the quantification of cells exhibiting low metabolic activity including senescent cells. The developed procedure provides high linearity and the signal is high for at least 20 days at room temperature. Only around 90 to 120 minutes is required for the procedure's completion.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc20028892
- 003
- CZ-PrNML
- 005
- 20210114155305.0
- 007
- ta
- 008
- 210105s2019 xxk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1038/s41598-019-45217-9 $2 doi
- 035 __
- $a (PubMed)31213648
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Ligasová, Anna $u Institute of Molecular and Translational Medicine, Faculty of Medicine and Dentistry, Palacký University in Olomouc, Olomouc, 779 00, Czech Republic. anna.ligasova@upol.cz.
- 245 10
- $a Quantification of fixed adherent cells using a strong enhancer of the fluorescence of DNA dyes / $c A. Ligasová, K. Koberna,
- 520 9_
- $a Cell quantification is widely used in basic or applied research. The current sensitive methods of cell quantification are exclusively based on the analysis of non-fixed cells and do not allow the simultaneous detection of various cellular components. A fast, sensitive and cheap method of the quantification of fixed adherent cells is described here. It is based on the incubation of DAPI- or Hoechst 33342-stained cells in a solution containing SDS. The presence of SDS results in the quick de-staining of DNA and simultaneously, in an up-to-1,000-fold increase of the fluorescence intensity of the used dyes. This increase can be attributed to the micelle formation of SDS. The method is sufficiently sensitive to reveal around 50-70 human diploid cells. It is compatible with immunocytochemical detections, the detection of DNA replication and cell cycle analysis by image cytometry. The procedure was successfully tested for the analysis of cytotoxicity. The method is suitable for the quantification of cells exhibiting low metabolic activity including senescent cells. The developed procedure provides high linearity and the signal is high for at least 20 days at room temperature. Only around 90 to 120 minutes is required for the procedure's completion.
- 650 _2
- $a buněčná adheze $7 D002448
- 650 _2
- $a počet buněk $x přístrojové vybavení $x metody $7 D002452
- 650 _2
- $a buněčný cyklus $7 D002453
- 650 _2
- $a buněčné linie $7 D002460
- 650 _2
- $a nádorové buněčné linie $7 D045744
- 650 _2
- $a viabilita buněk $7 D002470
- 650 _2
- $a cytofotometrie $x metody $7 D003592
- 650 _2
- $a DNA $x analýza $x chemie $7 D004247
- 650 12
- $a replikace DNA $7 D004261
- 650 12
- $a diploidie $7 D004171
- 650 _2
- $a fluorescenční barviva $x chemie $7 D005456
- 650 _2
- $a HeLa buňky $7 D006367
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a dodecylsíran sodný $x chemie $7 D012967
- 650 _2
- $a barvení a značení $x metody $7 D013194
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Koberna, Karel $u Institute of Molecular and Translational Medicine, Faculty of Medicine and Dentistry, Palacký University in Olomouc, Olomouc, 779 00, Czech Republic. karel.koberna@upol.cz.
- 773 0_
- $w MED00182195 $t Scientific reports $x 2045-2322 $g Roč. 9, č. 1 (2019), s. 8701
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/31213648 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20210105 $b ABA008
- 991 __
- $a 20210114155303 $b ABA008
- 999 __
- $a ok $b bmc $g 1609227 $s 1120072
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2019 $b 9 $c 1 $d 8701 $e 20190618 $i 2045-2322 $m Scientific reports $n Sci Rep $x MED00182195
- LZP __
- $a Pubmed-20210105