A highly effective way to improve the prognosis of viral infectious diseases is early detection of antibodies to various viral pathogens in biological fluids. Among a wide range of viral pathogens, tick-borne encephalitis virus (TBEV) attracts a special attention. This work reports a comparison between two bioanalytical methods (enzyme‑linked immunosorbent assay (ELISA) and voltammetric immunoassay) to determine antibodies to TBEV in a human blood serum. In these assays, the detected mo­lecule binds to the conjugate which is labelled with enzyme (in ELISA) or silver nanoparticles (in voltammetric immunoassay). In the ELISA, the signal corresponding to a colour-producing substrate (3,3',5,5'-tetramethylbenzidine) through an enzymatic reaction is detected using a spectrophotometer at a wavelength of 450 nm. In the electrochemical immunoassay, the signal is read by the linear sweep anodic stripping voltammetry (LSASV) of silver ions (through the electrochemical stripping of accumulated elemental silver) on a graphite composite electrode. The results of both measurements demonstrated that signals increased with the increasing concentration of the target antibodies to TBEV within the range from 100 to 1600 IU mL–1. Detection limits for ELISA and voltammetric assay were 30 and 90 IU mL–1, respectively. The practical application of both immunoanalytical approaches has been verified by determining the amount of antibodies to TBEV in the human blood serum. The obtained results clearly showed an excellent agreement between the detected concentration values of antibodies to TBEV obtained by the electrochemical method and by the standard ELISA method.

Comparison of Two Immunoanalytical Methods for Determination of Antibodies to Tick-Borne Encephalitis Virus

Bibliografie atd.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc21002174
003      
CZ-PrNML
005      
20210120113014.0
007      
ta
008      
210120s2020 xr d f 000 0|cze||
009      
AR
040    __
$a ABA008 $d ABA008 $e AACR2 $b cze
041    0_
$a cze $b eng
044    __
$a xr
100    1_
$a Khristunova, Ekaterina $7 _AN108838 $u National Research Tomsk Polytechnic University, Tomsk, Ruská federace; UNESCO laboratoř elektrochemie životního prostředí, Katedra analytické chemie, Přírodovědecká fakulta, Univerzita Karlova, Praha, Česká republika; Ústav chemie pevných látek, Vysoká škola chemicko-technologická v Praze, Praha, Česká republika
245    10
$a Porovnání dvou imunoanalytických metod pro stanovení protilátek proti viru klíšťové encefalitidy / $c Ekaterina Khristunova, Jiří Barek, Bohumil Kratochvíl, Elena Korotkova, Elena Dorozhko, Vlastimil Vyskočil
246    31
$a Comparison of Two Immunoanalytical Methods for Determination of Antibodies to Tick-Borne Encephalitis Virus
504    __
$a Literatura
520    9_
$a A highly effective way to improve the prognosis of viral infectious diseases is early detection of antibodies to various viral pathogens in biological fluids. Among a wide range of viral pathogens, tick-borne encephalitis virus (TBEV) attracts a special attention. This work reports a comparison between two bioanalytical methods (enzyme‑linked immunosorbent assay (ELISA) and voltammetric immunoassay) to determine antibodies to TBEV in a human blood serum. In these assays, the detected mo­lecule binds to the conjugate which is labelled with enzyme (in ELISA) or silver nanoparticles (in voltammetric immunoassay). In the ELISA, the signal corresponding to a colour-producing substrate (3,3',5,5'-tetramethylbenzidine) through an enzymatic reaction is detected using a spectrophotometer at a wavelength of 450 nm. In the electrochemical immunoassay, the signal is read by the linear sweep anodic stripping voltammetry (LSASV) of silver ions (through the electrochemical stripping of accumulated elemental silver) on a graphite composite electrode. The results of both measurements demonstrated that signals increased with the increasing concentration of the target antibodies to TBEV within the range from 100 to 1600 IU mL–1. Detection limits for ELISA and voltammetric assay were 30 and 90 IU mL–1, respectively. The practical application of both immunoanalytical approaches has been verified by determining the amount of antibodies to TBEV in the human blood serum. The obtained results clearly showed an excellent agreement between the detected concentration values of antibodies to TBEV obtained by the electrochemical method and by the standard ELISA method.
700    1_
$a Barek, Jiří, $d 1949- $7 jn20000400068 $u National Research Tomsk Polytechnic University, Tomsk, Ruská federace; UNESCO laboratoř elektrochemie životního prostředí, Katedra analytické chemie, Přírodovědecká fakulta, Univerzita Karlova, Praha, Česká republika
700    1_
$a Kratochvíl, Bohumil, $d 1949- $7 jo2001100055 $u National Research Tomsk Polytechnic University, Tomsk, Ruská federace; Ústav chemie pevných látek, Vysoká škola chemicko-technologická v Praze, Praha, Česká republika
700    1_
$a Korotkova, Elena $u National Research Tomsk Polytechnic University, Tomsk, Ruská federace
700    1_
$a Dorozhko, Elena $u National Research Tomsk Polytechnic University, Tomsk, Ruská federace
700    1_
$a Vyskočil, Vlastimil $7 xx0098665 $u UNESCO laboratoř elektrochemie životního prostředí, Katedra analytické chemie, Přírodovědecká fakulta, Univerzita Karlova, Praha, Česká republika
773    0_
$t Chemické listy $x 0009-2770 $g Roč. 114, č. 9 (2020), s. 618-622 $w MED00011010
856    41
$u http://www.chemicke-listy.cz/ojs3/index.php/chemicke-listy/article/view/3694/3627 $y plný text volně přístupný
910    __
$a ABA008 $b B 1918 $c 395 $y 0 $z 0
990    __
$a 20210120085822 $b ABA008
991    __
$a 20210120113013 $b ABA008
999    __
$a min $b bmc $g 1611542 $s 1122459
BAS    __
$a 3
BMC    __
$a 2020 $b 114 $c 9 $d 618-622 $i 0009-2770 $m Chemické listy $x MED00011010
LZP    __
$a NLK 2021-05/kv

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...