Tutorial and spreadsheet for the evaluation of instrumental quantification uncertainty by the linear weighted regression model: Determination of elemental impurities in a nasal spray by ICP-MS

T. Pluháček, D. Milde, J. Součková, RJN. Bettencourt da Silva

. 2021 ; 225 (-) : 122044. [pub] 20201224

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc21018973

A tutorial and spreadsheet for the validation and bottom-up uncertainty evaluation of quantifications performed by instrumental methods of analysis based on linear weighted calibrations is presented. The developed tool automatically assesses if calibrator values uncertainty is negligible given instrumental signal precision, assesses signal homoscedasticity by the Levene's test, guides the selection of weighting factors and evaluates the fitness of the regression model to define the calibration curve. The spreadsheet allows the use of the linear weighted regression model without the need for collecting many replicate signals of calibrators and sample by taking previously developed detailed models of signal precision variation in the calibration interval after adjustments to the daily precision conditions. This tool was successfully applied to the determination of the mass concentration of Cd, Pb, As, Hg, Co, V and Ni in a nasal spray by ICP-MS after samples dilution and acidification. The developed uncertainty models were checked through the analysis of nasal sprays after spiking with known analyte concentration levels. The metrological compatibility between estimated and reference analyte levels for 95% or 99% confidence level supports uncertainty model adequacy. The spiked samples were quantified from many replicate signals but uncertainty evaluation from duplicate calibrator and sample signals was assessed by randomly selecting calibrators and sample signals and by numerically defining a minimum acceptable success rate of the compatibility tests. The developed model was proven adequate to quantify the uncertainty of the studied measurements.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc21018973
003      
CZ-PrNML
005      
20220328110114.0
007      
ta
008      
210728s2021 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.talanta.2020.122044 $2 doi
035    __
$a (PubMed)33592767
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Pluháček, Tomáš $u Department of Analytical Chemistry, Faculty of Science, Palacký University Olomouc, 17. listopadu 12, 771 46, Olomouc, Czech Republic
245    10
$a Tutorial and spreadsheet for the evaluation of instrumental quantification uncertainty by the linear weighted regression model: Determination of elemental impurities in a nasal spray by ICP-MS / $c T. Pluháček, D. Milde, J. Součková, RJN. Bettencourt da Silva
520    9_
$a A tutorial and spreadsheet for the validation and bottom-up uncertainty evaluation of quantifications performed by instrumental methods of analysis based on linear weighted calibrations is presented. The developed tool automatically assesses if calibrator values uncertainty is negligible given instrumental signal precision, assesses signal homoscedasticity by the Levene's test, guides the selection of weighting factors and evaluates the fitness of the regression model to define the calibration curve. The spreadsheet allows the use of the linear weighted regression model without the need for collecting many replicate signals of calibrators and sample by taking previously developed detailed models of signal precision variation in the calibration interval after adjustments to the daily precision conditions. This tool was successfully applied to the determination of the mass concentration of Cd, Pb, As, Hg, Co, V and Ni in a nasal spray by ICP-MS after samples dilution and acidification. The developed uncertainty models were checked through the analysis of nasal sprays after spiking with known analyte concentration levels. The metrological compatibility between estimated and reference analyte levels for 95% or 99% confidence level supports uncertainty model adequacy. The spiked samples were quantified from many replicate signals but uncertainty evaluation from duplicate calibrator and sample signals was assessed by randomly selecting calibrators and sample signals and by numerically defining a minimum acceptable success rate of the compatibility tests. The developed model was proven adequate to quantify the uncertainty of the studied measurements.
650    _2
$a kalibrace $7 D002138
650    _2
$a lineární modely $7 D016014
650    12
$a nosní spreje $7 D059085
650    _2
$a spektrální analýza $7 D013057
650    _2
$a nejistota $7 D035501
655    _2
$a časopisecké články $7 D016428
700    1_
$a Milde, David, $u Department of Analytical Chemistry, Faculty of Science, Palacký University Olomouc, 17. listopadu 12, 771 46, Olomouc, Czech Republic $d 1973- $7 ola2002157911
700    1_
$a Součková, Jitka $u Department of Analytical Chemistry, Faculty of Science, Palacký University Olomouc, 17. listopadu 12, 771 46, Olomouc, Czech Republic
700    1_
$a Bettencourt da Silva, Ricardo J N $u Centro de Química Estrutural, Faculdade de Ciências, Universidade de Lisboa, Campo Grande, 1749-016, Lisboa, Portugal. Electronic address: rjsilva@fc.ul.pt
773    0_
$w MED00004484 $t Talanta $x 1873-3573 $g Roč. 225, č. - (2021), s. 122044
856    41
$u https://pubmed.ncbi.nlm.nih.gov/33592767 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20210728 $b ABA008
991    __
$a 20220328110112 $b ABA008
999    __
$a ok $b bmc $g 1689912 $s 1139419
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 225 $c - $d 122044 $e 20201224 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
LZP    __
$a Pubmed-20210728

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...