In vitro hemocompatibility testing of medical devices

M. Nalezinková

. 2020 ; 195 (-) : 146-150. [pub] 20200714

Jazyk angličtina Země Spojené státy americké

Typ dokumentu časopisecké články, práce podpořená grantem, přehledy

Perzistentní odkaz   https://www.medvik.cz/link/bmc21019940

Hemocompatibility testing is essential for the safe use of medical devices that come into contact with blood. There are various evaluation methodologies. In vivo, ex vivo and in vitro systems can be used and different categories can be evaluated in different ways. This review deals with in vitro hemocompatibility testing mainly on the basis of ISO standard 10993-4 recommendations and possibly new research results. This is a summary of all tested categories, i.e. coagulation, hemolysis, hematology and activation of leukocytes and platelets and the complement system. The main principle of evaluation and the possibilities of testing using various methodologies are always described. In the next part, variants of the method of blood incubation with the tested medical device from the static system to the circulation are described. Circulation can be provided, for example, by means of the Chandler Loop or parallel-plate chambers.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc21019940
003      
CZ-PrNML
005      
20210830101540.0
007      
ta
008      
210728s2020 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.thromres.2020.07.027 $2 doi
035    __
$a (PubMed)32698094
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Nalezinková, Martina $u Department of Biology, University of Hradec Králové, Rokitanského 62, Hradec Králové 500 03, Czech Republic. Electronic address: martina.nalezinkova@uhk.cz
245    10
$a In vitro hemocompatibility testing of medical devices / $c M. Nalezinková
520    9_
$a Hemocompatibility testing is essential for the safe use of medical devices that come into contact with blood. There are various evaluation methodologies. In vivo, ex vivo and in vitro systems can be used and different categories can be evaluated in different ways. This review deals with in vitro hemocompatibility testing mainly on the basis of ISO standard 10993-4 recommendations and possibly new research results. This is a summary of all tested categories, i.e. coagulation, hemolysis, hematology and activation of leukocytes and platelets and the complement system. The main principle of evaluation and the possibilities of testing using various methodologies are always described. In the next part, variants of the method of blood incubation with the tested medical device from the static system to the circulation are described. Circulation can be provided, for example, by means of the Chandler Loop or parallel-plate chambers.
650    12
$a hemokoagulace $7 D001777
650    12
$a trombocyty $7 D001792
650    _2
$a hemolýza $7 D006461
650    _2
$a lidé $7 D006801
650    _2
$a techniky in vitro $7 D066298
650    _2
$a testování materiálů $7 D008422
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
655    _2
$a přehledy $7 D016454
773    0_
$w MED00004518 $t Thrombosis research $x 1879-2472 $g Roč. 195, č. - (2020), s. 146-150
856    41
$u https://pubmed.ncbi.nlm.nih.gov/32698094 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20210728 $b ABA008
991    __
$a 20210830101540 $b ABA008
999    __
$a ok $b bmc $g 1690692 $s 1140386
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2020 $b 195 $c - $d 146-150 $e 20200714 $i 1879-2472 $m Thrombosis research $n Thromb Res $x MED00004518
LZP    __
$a Pubmed-20210728

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...