In vitro hemocompatibility testing of medical devices
M. Nalezinková
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články, práce podpořená grantem, přehledy
- MeSH
- hemokoagulace * MeSH
- hemolýza MeSH
- lidé MeSH
- techniky in vitro MeSH
- testování materiálů MeSH
- trombocyty * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- přehledy MeSH
Hemocompatibility testing is essential for the safe use of medical devices that come into contact with blood. There are various evaluation methodologies. In vivo, ex vivo and in vitro systems can be used and different categories can be evaluated in different ways. This review deals with in vitro hemocompatibility testing mainly on the basis of ISO standard 10993-4 recommendations and possibly new research results. This is a summary of all tested categories, i.e. coagulation, hemolysis, hematology and activation of leukocytes and platelets and the complement system. The main principle of evaluation and the possibilities of testing using various methodologies are always described. In the next part, variants of the method of blood incubation with the tested medical device from the static system to the circulation are described. Circulation can be provided, for example, by means of the Chandler Loop or parallel-plate chambers.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21019940
- 003
- CZ-PrNML
- 005
- 20210830101540.0
- 007
- ta
- 008
- 210728s2020 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.thromres.2020.07.027 $2 doi
- 035 __
- $a (PubMed)32698094
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Nalezinková, Martina $u Department of Biology, University of Hradec Králové, Rokitanského 62, Hradec Králové 500 03, Czech Republic. Electronic address: martina.nalezinkova@uhk.cz
- 245 10
- $a In vitro hemocompatibility testing of medical devices / $c M. Nalezinková
- 520 9_
- $a Hemocompatibility testing is essential for the safe use of medical devices that come into contact with blood. There are various evaluation methodologies. In vivo, ex vivo and in vitro systems can be used and different categories can be evaluated in different ways. This review deals with in vitro hemocompatibility testing mainly on the basis of ISO standard 10993-4 recommendations and possibly new research results. This is a summary of all tested categories, i.e. coagulation, hemolysis, hematology and activation of leukocytes and platelets and the complement system. The main principle of evaluation and the possibilities of testing using various methodologies are always described. In the next part, variants of the method of blood incubation with the tested medical device from the static system to the circulation are described. Circulation can be provided, for example, by means of the Chandler Loop or parallel-plate chambers.
- 650 12
- $a hemokoagulace $7 D001777
- 650 12
- $a trombocyty $7 D001792
- 650 _2
- $a hemolýza $7 D006461
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a techniky in vitro $7 D066298
- 650 _2
- $a testování materiálů $7 D008422
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 655 _2
- $a přehledy $7 D016454
- 773 0_
- $w MED00004518 $t Thrombosis research $x 1879-2472 $g Roč. 195, č. - (2020), s. 146-150
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/32698094 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20210728 $b ABA008
- 991 __
- $a 20210830101540 $b ABA008
- 999 __
- $a ok $b bmc $g 1690692 $s 1140386
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $b 195 $c - $d 146-150 $e 20200714 $i 1879-2472 $m Thrombosis research $n Thromb Res $x MED00004518
- LZP __
- $a Pubmed-20210728