-
Je něco špatně v tomto záznamu ?
Advances in accelerometry for cardiovascular patients: a systematic review with practical recommendations
T. Vetrovsky, CCT. Clark, MC. Bisi, M. Siranec, A. Linhart, JJ. Tufano, MJ. Duncan, J. Belohlavek
Jazyk angličtina Země Velká Británie
Typ dokumentu časopisecké články, práce podpořená grantem, přehledy, systematický přehled
Grantová podpora
NV18-09-00146
Czech Health Research Council - International
NLK
Directory of Open Access Journals
od 2014
Free Medical Journals
od 2014
PubMed Central
od 2015
Europe PubMed Central
od 2015
ProQuest Central
od 2014-09-01
Open Access Digital Library
od 2014-09-01
Open Access Digital Library
od 2014-01-01
Health & Medicine (ProQuest)
od 2014-09-01
Wiley Free Content
od 2014
Wiley-Blackwell Open Access Titles
od 2014
ROAD: Directory of Open Access Scholarly Resources
od 2014
PubMed
32618431
DOI
10.1002/ehf2.12781
Knihovny.cz E-zdroje
- MeSH
- akcelerometrie MeSH
- cvičení MeSH
- kardiovaskulární nemoci * MeSH
- lidé MeSH
- srdeční selhání * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- přehledy MeSH
- systematický přehled MeSH
AIMS: Accelerometers are becoming increasingly commonplace for assessing physical activity; however, their use in patients with cardiovascular diseases is relatively substandard. We aimed to systematically review the methods used for collecting and processing accelerometer data in cardiology, using the example of heart failure, and to provide practical recommendations on how to improve objective physical activity assessment in patients with cardiovascular diseases by using accelerometers. METHODS AND RESULTS: Four electronic databases were searched up to September 2019 for observational, interventional, and validation studies using accelerometers to assess physical activity in patients with heart failure. Study and population characteristics, details of accelerometry data collection and processing, and description of physical activity metrics were extracted from the eligible studies and synthesized. To assess the quality and completeness of accelerometer reporting, the studies were scored using 12 items on data collection and processing, such as the placement of accelerometer, days of data collected, and criteria for non-wear of the accelerometer. In 60 eligible studies with 3500 patients (of those, 536 were heart failure with preserved ejection fraction patients), a wide variety of accelerometer brands (n = 27) and models (n = 46) were used, with Actigraph being the most frequent (n = 12), followed by Fitbit (n = 5). The accelerometer was usually worn on the hip (n = 32), and the most prevalent wear period was 7 days (n = 22). The median wear time required for a valid day was 600 min, and between two and five valid days was required for a patient to be included in the analysis. The most common measures of physical activity were steps (n = 20), activity counts (n = 15), and time spent in moderate-to-vigorous physical activity (n = 14). Only three studies validated accelerometers in a heart failure population, showing that their accuracy deteriorates at slower speeds. Studies failed to report between one and six (median 4) of the 12 scored items, with non-wear time criteria and valid day definition being the most underreported items. CONCLUSIONS: The use of accelerometers in cardiology lacks consistency and reporting on data collection, and processing methods need to be improved. Furthermore, calculating metrics based on raw acceleration and machine learning techniques is lacking, opening the opportunity for future exploration. Therefore, we encourage researchers and clinicians to improve the quality and transparency of data collection and processing by following our proposed practical recommendations for using accelerometers in patients with cardiovascular diseases, which are outlined in the article.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21020038
- 003
- CZ-PrNML
- 005
- 20210830101636.0
- 007
- ta
- 008
- 210728s2020 xxk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1002/ehf2.12781 $2 doi
- 035 __
- $a (PubMed)32618431
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Vetrovsky, Tomas $u Department of Physiology and Biochemistry, Faculty of Physical Education and Sport, Charles University, Prague, Czech Republic
- 245 10
- $a Advances in accelerometry for cardiovascular patients: a systematic review with practical recommendations / $c T. Vetrovsky, CCT. Clark, MC. Bisi, M. Siranec, A. Linhart, JJ. Tufano, MJ. Duncan, J. Belohlavek
- 520 9_
- $a AIMS: Accelerometers are becoming increasingly commonplace for assessing physical activity; however, their use in patients with cardiovascular diseases is relatively substandard. We aimed to systematically review the methods used for collecting and processing accelerometer data in cardiology, using the example of heart failure, and to provide practical recommendations on how to improve objective physical activity assessment in patients with cardiovascular diseases by using accelerometers. METHODS AND RESULTS: Four electronic databases were searched up to September 2019 for observational, interventional, and validation studies using accelerometers to assess physical activity in patients with heart failure. Study and population characteristics, details of accelerometry data collection and processing, and description of physical activity metrics were extracted from the eligible studies and synthesized. To assess the quality and completeness of accelerometer reporting, the studies were scored using 12 items on data collection and processing, such as the placement of accelerometer, days of data collected, and criteria for non-wear of the accelerometer. In 60 eligible studies with 3500 patients (of those, 536 were heart failure with preserved ejection fraction patients), a wide variety of accelerometer brands (n = 27) and models (n = 46) were used, with Actigraph being the most frequent (n = 12), followed by Fitbit (n = 5). The accelerometer was usually worn on the hip (n = 32), and the most prevalent wear period was 7 days (n = 22). The median wear time required for a valid day was 600 min, and between two and five valid days was required for a patient to be included in the analysis. The most common measures of physical activity were steps (n = 20), activity counts (n = 15), and time spent in moderate-to-vigorous physical activity (n = 14). Only three studies validated accelerometers in a heart failure population, showing that their accuracy deteriorates at slower speeds. Studies failed to report between one and six (median 4) of the 12 scored items, with non-wear time criteria and valid day definition being the most underreported items. CONCLUSIONS: The use of accelerometers in cardiology lacks consistency and reporting on data collection, and processing methods need to be improved. Furthermore, calculating metrics based on raw acceleration and machine learning techniques is lacking, opening the opportunity for future exploration. Therefore, we encourage researchers and clinicians to improve the quality and transparency of data collection and processing by following our proposed practical recommendations for using accelerometers in patients with cardiovascular diseases, which are outlined in the article.
- 650 _2
- $a akcelerometrie $7 D061725
- 650 12
- $a kardiovaskulární nemoci $7 D002318
- 650 _2
- $a cvičení $7 D015444
- 650 12
- $a srdeční selhání $7 D006333
- 650 _2
- $a lidé $7 D006801
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 655 _2
- $a přehledy $7 D016454
- 655 _2
- $a systematický přehled $7 D000078182
- 700 1_
- $a Clark, Cain C T $u Faculty of Health and Life Sciences, Coventry University, Coventry, UK
- 700 1_
- $a Bisi, Maria Cristina $u Department of Electrical, Electronic and Information Engineering 'Guglielmo Marconi', DEI, University of Bologna, Bologna, Italy
- 700 1_
- $a Siranec, Michal $u 2nd Department of Medicine-Department of Cardiovascular Medicine, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic
- 700 1_
- $a Linhart, Ales $u 2nd Department of Medicine-Department of Cardiovascular Medicine, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic
- 700 1_
- $a Tufano, James J $u Department of Physiology and Biochemistry, Faculty of Physical Education and Sport, Charles University, Prague, Czech Republic
- 700 1_
- $a Duncan, Michael J $u Faculty of Health and Life Sciences, Coventry University, Coventry, UK
- 700 1_
- $a Belohlavek, Jan $u 2nd Department of Medicine-Department of Cardiovascular Medicine, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic
- 773 0_
- $w MED00197251 $t ESC heart failure $x 2055-5822 $g Roč. 7, č. 5 (2020), s. 2021-2031
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/32618431 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20210728 $b ABA008
- 991 __
- $a 20210830101636 $b ABA008
- 999 __
- $a ok $b bmc $g 1690765 $s 1140484
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $b 7 $c 5 $d 2021-2031 $e 20200703 $i 2055-5822 $m ESC heart failure $n ESC Heart Fail $x MED00197251
- GRA __
- $a NV18-09-00146 $p Czech Health Research Council $2 International
- LZP __
- $a Pubmed-20210728