The influence of scar on the spatio-temporal relationship between electrical and mechanical activation in heart failure patients
F. Maffessanti, T. Jadczyk, R. Kurzelowski, F. Regoli, ML. Caputo, G. Conte, KS. Gołba, J. Biernat, J. Wilczek, M. Dąbrowska, S. Pezzuto, T. Moccetti, R. Krause, W. Wojakowski, FW. Prinzen, A. Auricchio
Jazyk angličtina Země Velká Británie
Typ dokumentu časopisecké články, práce podpořená grantem
NLK
Free Medical Journals
od 1999 do Před 1 rokem
PubMed Central
od 2008
Open Access Digital Library
od 1999-01-01
Medline Complete (EBSCOhost)
od 1999-01-01
Oxford Journals Open Access Collection
od 1999-01-01
PubMed
31942982
DOI
10.1093/europace/euz346
Knihovny.cz E-zdroje
- MeSH
- jizva diagnostické zobrazování MeSH
- lidé MeSH
- magnetická rezonance kinematografická MeSH
- srdeční komory diagnostické zobrazování MeSH
- srdeční resynchronizační terapie * MeSH
- srdeční selhání * diagnostické zobrazování terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
AIMS: The aim of this study was to determine the relationship between electrical and mechanical activation in heart failure (HF) patients and whether electromechanical coupling is affected by scar. METHODS AND RESULTS: Seventy HF patients referred for cardiac resynchronization therapy or biological therapy underwent endocardial anatomo-electromechanical mapping (AEMM) and delayed-enhancement magnetic resonance (CMR) scans. Area strain and activation times were derived from AEMM data, allowing to correlate mechanical and electrical activation in time and space with unprecedented accuracy. Special attention was paid to the effect of presence of CMR-evidenced scar. Patients were divided into a scar (n = 43) and a non-scar group (n-27). Correlation between time of electrical and mechanical activation was stronger in the non-scar compared to the scar group [R = 0.84 (0.72-0.89) vs. 0.74 (0.52-0.88), respectively; P = 0.01]. The overlap between latest electrical and mechanical activation areas was larger in the absence than in presence of scar [72% (54-81) vs. 56% (36-73), respectively; P = 0.02], with smaller distance between the centroids of the two regions [10.7 (4.9-17.4) vs. 20.3 (6.9-29.4) % of left ventricular radius, P = 0.02]. CONCLUSION: Scar decreases the association between electrical and mechanical activation, even when scar is remote from late activated regions.
Department of Electrocardiology and Heart Failure Medical University of Silesia Katowice Poland
Department of Physiology CARIM Maastricht University Maastricht The Netherlands
Division of Cardiology and Structural Heart Diseases Medical University of Silesia Katowice Poland
Division of Cardiology Fondazione Cardiocentro Ticino Lugano Switzerland
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21020574
- 003
- CZ-PrNML
- 005
- 20210830102222.0
- 007
- ta
- 008
- 210728s2020 xxk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1093/europace/euz346 $2 doi
- 035 __
- $a (PubMed)31942982
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Maffessanti, Francesco $u Center for Computational Medicine in Cardiology, Università della Svizzera italiana, Via G. Buffi 13, CH-6900 Lugano, Switzerland
- 245 14
- $a The influence of scar on the spatio-temporal relationship between electrical and mechanical activation in heart failure patients / $c F. Maffessanti, T. Jadczyk, R. Kurzelowski, F. Regoli, ML. Caputo, G. Conte, KS. Gołba, J. Biernat, J. Wilczek, M. Dąbrowska, S. Pezzuto, T. Moccetti, R. Krause, W. Wojakowski, FW. Prinzen, A. Auricchio
- 520 9_
- $a AIMS: The aim of this study was to determine the relationship between electrical and mechanical activation in heart failure (HF) patients and whether electromechanical coupling is affected by scar. METHODS AND RESULTS: Seventy HF patients referred for cardiac resynchronization therapy or biological therapy underwent endocardial anatomo-electromechanical mapping (AEMM) and delayed-enhancement magnetic resonance (CMR) scans. Area strain and activation times were derived from AEMM data, allowing to correlate mechanical and electrical activation in time and space with unprecedented accuracy. Special attention was paid to the effect of presence of CMR-evidenced scar. Patients were divided into a scar (n = 43) and a non-scar group (n-27). Correlation between time of electrical and mechanical activation was stronger in the non-scar compared to the scar group [R = 0.84 (0.72-0.89) vs. 0.74 (0.52-0.88), respectively; P = 0.01]. The overlap between latest electrical and mechanical activation areas was larger in the absence than in presence of scar [72% (54-81) vs. 56% (36-73), respectively; P = 0.02], with smaller distance between the centroids of the two regions [10.7 (4.9-17.4) vs. 20.3 (6.9-29.4) % of left ventricular radius, P = 0.02]. CONCLUSION: Scar decreases the association between electrical and mechanical activation, even when scar is remote from late activated regions.
- 650 12
- $a srdeční resynchronizační terapie $7 D058406
- 650 _2
- $a jizva $x diagnostické zobrazování $7 D002921
- 650 12
- $a srdeční selhání $x diagnostické zobrazování $x terapie $7 D006333
- 650 _2
- $a srdeční komory $x diagnostické zobrazování $7 D006352
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a magnetická rezonance kinematografická $7 D019028
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Jadczyk, Tomasz $u Division of Cardiology and Structural Heart Diseases, Medical University of Silesia, Katowice, Poland $u Interventional Cardiac Electrophysiology Group, International Clinical Research Center, St. Anne's University Hospital Brno, Czech Republic
- 700 1_
- $a Kurzelowski, Radosław $u Division of Cardiology and Structural Heart Diseases, Medical University of Silesia, Katowice, Poland
- 700 1_
- $a Regoli, François $u Division of Cardiology, Fondazione Cardiocentro Ticino, Lugano, Switzerland
- 700 1_
- $a Caputo, Maria Luce $u Division of Cardiology, Fondazione Cardiocentro Ticino, Lugano, Switzerland
- 700 1_
- $a Conte, Giulio $u Division of Cardiology, Fondazione Cardiocentro Ticino, Lugano, Switzerland
- 700 1_
- $a Gołba, Krzysztof S $u Department of Electrocardiology and Heart Failure, Medical University of Silesia, Katowice, Poland
- 700 1_
- $a Biernat, Jolanta $u Department of Electrocardiology and Heart Failure, Medical University of Silesia, Katowice, Poland
- 700 1_
- $a Wilczek, Jacek $u Department of Electrocardiology and Heart Failure, Medical University of Silesia, Katowice, Poland
- 700 1_
- $a Dąbrowska, Magdalena $u Department of Electrocardiology and Heart Failure, Medical University of Silesia, Katowice, Poland
- 700 1_
- $a Pezzuto, Simone $u Center for Computational Medicine in Cardiology, Università della Svizzera italiana, Via G. Buffi 13, CH-6900 Lugano, Switzerland
- 700 1_
- $a Moccetti, Tiziano $u Division of Cardiology, Fondazione Cardiocentro Ticino, Lugano, Switzerland
- 700 1_
- $a Krause, Rolf $u Center for Computational Medicine in Cardiology, Università della Svizzera italiana, Via G. Buffi 13, CH-6900 Lugano, Switzerland
- 700 1_
- $a Wojakowski, Wojciech $u Division of Cardiology and Structural Heart Diseases, Medical University of Silesia, Katowice, Poland
- 700 1_
- $a Prinzen, Frits W $u Department of Physiology, CARIM, Maastricht University, Maastricht, The Netherlands
- 700 1_
- $a Auricchio, Angelo $u Center for Computational Medicine in Cardiology, Università della Svizzera italiana, Via G. Buffi 13, CH-6900 Lugano, Switzerland $u Division of Cardiology, Fondazione Cardiocentro Ticino, Lugano, Switzerland
- 773 0_
- $w MED00149837 $t Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology $x 1532-2092 $g Roč. 22, č. 5 (2020), s. 777-786
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/31942982 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20210728 $b ABA008
- 991 __
- $a 20210830102223 $b ABA008
- 999 __
- $a ok $b bmc $g 1691198 $s 1141020
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $b 22 $c 5 $d 777-786 $e 20200501 $i 1532-2092 $m Europace $n Europace $x MED00149837
- LZP __
- $a Pubmed-20210728