The effect of vibratory stimulation on the timed-up-and-go mobility test: a pilot study for sensory-related fall risk assessment
N. Toosizadeh, G. Wahlert, M. Fain, J. Mohler
Jazyk angličtina Země Česko
Typ dokumentu časopisecké články
NLK
Directory of Open Access Journals
od 1991
Free Medical Journals
od 1998
PubMed Central
od 2020
ProQuest Central
od 2005-01-01
Medline Complete (EBSCOhost)
od 2006-01-01
Nursing & Allied Health Database (ProQuest)
od 2005-01-01
Health & Medicine (ProQuest)
od 2005-01-01
ROAD: Directory of Open Access Scholarly Resources
od 1998
- MeSH
- biomechanika MeSH
- hodnocení rizik metody MeSH
- kosterní svaly fyziologie MeSH
- lidé MeSH
- pilotní projekty MeSH
- pohyb fyziologie MeSH
- posturální rovnováha fyziologie MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- techniky fyzikální terapie * MeSH
- úrazy pádem prevence a kontrola statistika a číselné údaje MeSH
- vibrace terapeutické užití MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
Effects of localized lower-extremity vibration on postural balance have been reported. The purpose of the current study was to investigate the effect of low-frequency vibration of calf muscles on the instrumented Timed-Up-and-Go (iTUG) test among older adults. Older adults were recruited and classified to low (n=10, age=72.9±2.8 years) and high fall risk (n=10, age=83.6±9.6) using STEADI. Vibratory system (30Hz or 40Hz), was positioned on calves along with wearable motion sensors. Participants performed the iTUG test three times, under conditions of no-vibration, 30Hz, and 40Hz vibration. Percentage differences in duration of iTUG components were calculated comparing vibration vs no-vibration conditions. Significant between-group differences were observed in iTUG (p=0.03); high fall risk participants showed reduction in the duration of turning (-10 % with 30Hz; p=0.15 and -15 % with 40Hz; p=0.03) and turning and sitting (-18 % with 30Hz; p=0.02 and -10 % with 40Hz; p=0.08). However, vibration increased turning (+18 % with 30Hz; p=0.20 and +27 % with 40Hz; p=0.12) and turning and sitting duration (+27 % with 30Hz; p=0.11 and +47 % with 40Hz; p=0.12) in low fall risk participants. Findings suggest that lower-extremity vibration affects dynamic balance; however, the level of this influence may differ between low and high fall risk older adults, which can potentially be used for assessing aging-related sensory deficits.
Arizona Center on Aging Department of Medicine University of Arizona USA
Department of Biomedical Engineering University of Arizona Tucson Arizona USA
Citace poskytuje Crossref.org
Literatura
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21021215
- 003
- CZ-PrNML
- 005
- 20210914152214.0
- 007
- ta
- 008
- 210806s2020 xr d f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.33549/physiolres.934451 $2 doi
- 035 __
- $a (PubMed)32672046
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Toosizadeh, N. $u Department of Biomedical Engineering, University of Arizona, Tucson, Arizona, USA $u Division of Geriatrics, General Internal Medicine and Palliative Medicine, Department of Medicine, University of Arizona, USA $u Arizona Center on Aging, Department of Medicine, University of Arizona, USA
- 245 14
- $a The effect of vibratory stimulation on the timed-up-and-go mobility test: a pilot study for sensory-related fall risk assessment / $c N. Toosizadeh, G. Wahlert, M. Fain, J. Mohler
- 504 __
- $a Literatura
- 520 9_
- $a Effects of localized lower-extremity vibration on postural balance have been reported. The purpose of the current study was to investigate the effect of low-frequency vibration of calf muscles on the instrumented Timed-Up-and-Go (iTUG) test among older adults. Older adults were recruited and classified to low (n=10, age=72.9±2.8 years) and high fall risk (n=10, age=83.6±9.6) using STEADI. Vibratory system (30Hz or 40Hz), was positioned on calves along with wearable motion sensors. Participants performed the iTUG test three times, under conditions of no-vibration, 30Hz, and 40Hz vibration. Percentage differences in duration of iTUG components were calculated comparing vibration vs no-vibration conditions. Significant between-group differences were observed in iTUG (p=0.03); high fall risk participants showed reduction in the duration of turning (-10 % with 30Hz; p=0.15 and -15 % with 40Hz; p=0.03) and turning and sitting (-18 % with 30Hz; p=0.02 and -10 % with 40Hz; p=0.08). However, vibration increased turning (+18 % with 30Hz; p=0.20 and +27 % with 40Hz; p=0.12) and turning and sitting duration (+27 % with 30Hz; p=0.11 and +47 % with 40Hz; p=0.12) in low fall risk participants. Findings suggest that lower-extremity vibration affects dynamic balance; however, the level of this influence may differ between low and high fall risk older adults, which can potentially be used for assessing aging-related sensory deficits.
- 650 _2
- $a úrazy pádem $x prevence a kontrola $x statistika a číselné údaje $7 D000058
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a senioři nad 80 let $7 D000369
- 650 _2
- $a biomechanika $7 D001696
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a pohyb $x fyziologie $7 D009068
- 650 _2
- $a kosterní svaly $x fyziologie $7 D018482
- 650 12
- $a techniky fyzikální terapie $7 D026741
- 650 _2
- $a pilotní projekty $7 D010865
- 650 _2
- $a posturální rovnováha $x fyziologie $7 D004856
- 650 _2
- $a hodnocení rizik $x metody $7 D018570
- 650 _2
- $a vibrace $x terapeutické užití $7 D014732
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Wahlert, G. $u Department of Biomedical Engineering, University of Arizona, Tucson, Arizona, USA
- 700 1_
- $a Fain, M. $u Division of Geriatrics, General Internal Medicine and Palliative Medicine, Department of Medicine, University of Arizona, USA $u Arizona Center on Aging, Department of Medicine, University of Arizona, USA
- 700 1_
- $a Mohler, J. $u Department of Biomedical Engineering, University of Arizona, Tucson, Arizona, USA
- 773 0_
- $w MED00003824 $t Physiological research $x 1802-9973 $g Roč. 69, č. 4 (2020), s. 721-730
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/32672046 $y Pubmed
- 910 __
- $a ABA008 $b A 4120 $c 266 $y p $z 0
- 990 __
- $a 20210806 $b ABA008
- 991 __
- $a 20210903122248 $b ABA008
- 999 __
- $a ok $b bmc $g 1697020 $s 1141668
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $b 69 $c 4 $d 721-730 $e 20200716 $i 1802-9973 $m Physiological research $n Physiol. Res. (Print) $x MED00003824