Detail
Article
Online article
FT
Medvik - BMC
  • Something wrong with this record ?

Inactivation of Acanthamoeba Cysts in Suspension and on Contaminated Contact Lenses Using Non-Thermal Plasma

T. Měřínská, V. Scholtz, J. Khun, J. Julák, E. Nohýnková

. 2021 ; 9 (9) : . [pub] 20210905

Language English Country Switzerland

Document type Journal Article

Grant support
Progress Q25 a Q26 Univerzita Karlova v Praze

Water suspensions of cysts of a pathogenic clinical isolate of Acanthamoeba sp. were prepared, and the cysts were inactivated either in suspension or placed on the surface of contact lenses by the non-thermal plasma produced by the DC corona transient spark discharge. The efficacy of this treatment was determined by cultivation and the presence of vegetative trophozoites indicating non-inactivated cysts. The negative discharge appeared to be more effective than the positive one. The complete inactivation occurred in water suspension after 40 min and on contaminated lenses after 50 min of plasma exposure. The properties of lenses seem to not be affected by plasma exposure; that is, their optical power, diameter, curvature, water content and infrared and Raman spectra remain unchanged.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc21023994
003      
CZ-PrNML
005      
20211013134101.0
007      
ta
008      
211006s2021 sz f 000 0|eng||
009      
AR
024    7_
$a 10.3390/microorganisms9091879 $2 doi
035    __
$a (PubMed)34576774
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a sz
100    1_
$a Měřínská, Tereza $u Department of Physics and Measurements, University of Chemistry and Technology, 166 28 Prague, Czech Republic
245    10
$a Inactivation of Acanthamoeba Cysts in Suspension and on Contaminated Contact Lenses Using Non-Thermal Plasma / $c T. Měřínská, V. Scholtz, J. Khun, J. Julák, E. Nohýnková
520    9_
$a Water suspensions of cysts of a pathogenic clinical isolate of Acanthamoeba sp. were prepared, and the cysts were inactivated either in suspension or placed on the surface of contact lenses by the non-thermal plasma produced by the DC corona transient spark discharge. The efficacy of this treatment was determined by cultivation and the presence of vegetative trophozoites indicating non-inactivated cysts. The negative discharge appeared to be more effective than the positive one. The complete inactivation occurred in water suspension after 40 min and on contaminated lenses after 50 min of plasma exposure. The properties of lenses seem to not be affected by plasma exposure; that is, their optical power, diameter, curvature, water content and infrared and Raman spectra remain unchanged.
655    _2
$a časopisecké články $7 D016428
700    1_
$a Scholtz, Vladimír $u Department of Physics and Measurements, University of Chemistry and Technology, 166 28 Prague, Czech Republic
700    1_
$a Khun, Josef $u Department of Physics and Measurements, University of Chemistry and Technology, 166 28 Prague, Czech Republic
700    1_
$a Julák, Jaroslav $u Institute of Immunology and Microbiology, 1st Faculty of Medicine, Charles University and General University Hospital in Prague, 128 00 Prague, Czech Republic
700    1_
$a Nohýnková, Eva $u Institute of Immunology and Microbiology, 1st Faculty of Medicine, Charles University and General University Hospital in Prague, 128 00 Prague, Czech Republic
773    0_
$w MED00198767 $t Microorganisms $x 2076-2607 $g Roč. 9, č. 9 (2021)
856    41
$u https://pubmed.ncbi.nlm.nih.gov/34576774 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20211006 $b ABA008
991    __
$a 20211013134058 $b ABA008
999    __
$a ind $b bmc $g 1708157 $s 1144488
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 9 $c 9 $e 20210905 $i 2076-2607 $m Microorganisms $n Microorganisms $x MED00198767
GRA    __
$a Progress Q25 a Q26 $p Univerzita Karlova v Praze
LZP    __
$a Pubmed-20211006

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...