Experimental model of occluded biliary metal stent recanalization using irreversible electroporation via a tubular catheter
T. Rohan, T. Andrasina, T. Juza, P. Matkulcik, D. Červinka, I. Svobodova, V. Novotná, V. Bernard, V. Valek, SN. Goldberg
Jazyk angličtina Země Velká Británie
Typ dokumentu časopisecké články, práce podpořená grantem
NLK
Directory of Open Access Journals
od 2019
Taylor & Francis Open Access
od 2018-05-03
Taylor & Francis Open Access
od 2019-01-01
Medline Complete (EBSCOhost)
od 1999-01-01
ROAD: Directory of Open Access Scholarly Resources
od 1985
- MeSH
- ablace * MeSH
- elektroporace * MeSH
- katétry MeSH
- prasata MeSH
- stenty MeSH
- teoretické modely MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
PURPOSE: To demonstrate the feasibility of irreversible electroporation (IRE) for treating biliary metal stent occlusion in an experimental liver model. METHODS AND MATERIALS: IRE was performed using an expandable tubular IRE-catheter placed in nitinol stents in the porcine liver. A 3-electrode IRE-catheter was connected to an IRE-generator and one hundred 100μs pulses of constant voltage (300, 650, 1000, and 1300 V) were applied. Stent occlusion was simulated by insertion of liver tissue both ex vivo (n = 94) and in vivo in 3 pigs (n = 14). Three scenarios of the relationship between the stent, electrodes, and inserted tissue (double contact, single contact, and stent mesh contact) were studied. Electric current was measured and resistance and power calculated. Pigs were sacrificed 72 h post-procedure. Harvested samples (14 experimental, 13 controls) underwent histopathological analysis. RESULTS: IRE application was feasible at 300 and 650 V for the single and double contact setup in both ex vivo and in vivo studies. Significant differences in calculated resistance between double contact and single contact settings were observed (ex-vivo p ˂ 0.0001, in-vivo p = 0.02; Mann-Whitney). A mild temperature increase of the surrounding liver parenchyma was noted with increasing voltage (0.9-5.9 °C for 300-1000 V). The extent of necrotic changes in experimental samples in vivo correlated with the measured electric current (r2 = 0.39, p = 0.01). No complications were observed during or after the in-vivo procedure. CONCLUSION: Endoluminal IRE using an expandable tubular catheter in simulated metal stent occlusion is feasible. The relationship of active catheter electrodes to stent ingrowth tissue can be estimated based on resistance values.
Department of Pathology St Anne's University Hospital Brno Brno Czech Republic
Faculty of Medicine Department of Biophysics Masaryk University Brno Czech Republic
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21026251
- 003
- CZ-PrNML
- 005
- 20211116135854.0
- 007
- ta
- 008
- 211013s2021 xxk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1080/02656736.2021.1875061 $2 doi
- 035 __
- $a (PubMed)33682581
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Rohan, T $u Department of Radiology and Nuclear Medicine, University Hospital Brno and Masaryk University Brno, Brno, Czech Republic
- 245 10
- $a Experimental model of occluded biliary metal stent recanalization using irreversible electroporation via a tubular catheter / $c T. Rohan, T. Andrasina, T. Juza, P. Matkulcik, D. Červinka, I. Svobodova, V. Novotná, V. Bernard, V. Valek, SN. Goldberg
- 520 9_
- $a PURPOSE: To demonstrate the feasibility of irreversible electroporation (IRE) for treating biliary metal stent occlusion in an experimental liver model. METHODS AND MATERIALS: IRE was performed using an expandable tubular IRE-catheter placed in nitinol stents in the porcine liver. A 3-electrode IRE-catheter was connected to an IRE-generator and one hundred 100μs pulses of constant voltage (300, 650, 1000, and 1300 V) were applied. Stent occlusion was simulated by insertion of liver tissue both ex vivo (n = 94) and in vivo in 3 pigs (n = 14). Three scenarios of the relationship between the stent, electrodes, and inserted tissue (double contact, single contact, and stent mesh contact) were studied. Electric current was measured and resistance and power calculated. Pigs were sacrificed 72 h post-procedure. Harvested samples (14 experimental, 13 controls) underwent histopathological analysis. RESULTS: IRE application was feasible at 300 and 650 V for the single and double contact setup in both ex vivo and in vivo studies. Significant differences in calculated resistance between double contact and single contact settings were observed (ex-vivo p ˂ 0.0001, in-vivo p = 0.02; Mann-Whitney). A mild temperature increase of the surrounding liver parenchyma was noted with increasing voltage (0.9-5.9 °C for 300-1000 V). The extent of necrotic changes in experimental samples in vivo correlated with the measured electric current (r2 = 0.39, p = 0.01). No complications were observed during or after the in-vivo procedure. CONCLUSION: Endoluminal IRE using an expandable tubular catheter in simulated metal stent occlusion is feasible. The relationship of active catheter electrodes to stent ingrowth tissue can be estimated based on resistance values.
- 650 12
- $a ablace $7 D055011
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a katétry $7 D057785
- 650 12
- $a elektroporace $7 D018274
- 650 _2
- $a teoretické modely $7 D008962
- 650 _2
- $a stenty $7 D015607
- 650 _2
- $a prasata $7 D013552
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Andrasina, T $u Department of Radiology and Nuclear Medicine, University Hospital Brno and Masaryk University Brno, Brno, Czech Republic
- 700 1_
- $a Juza, T $u Department of Radiology and Nuclear Medicine, University Hospital Brno and Masaryk University Brno, Brno, Czech Republic
- 700 1_
- $a Matkulcik, P $u Department of Radiology and Nuclear Medicine, University Hospital Brno and Masaryk University Brno, Brno, Czech Republic
- 700 1_
- $a Červinka, D $u Faculty of Electrical Engineering and Communication, Department of Power Electrical and Electronic Engineering, Brno University of Technology, Brno, Czech Republic
- 700 1_
- $a Svobodova, I $u Department of Pathology, St. Anne's University Hospital Brno, Brno, Czech Republic
- 700 1_
- $a Novotná, V $u Faculty of Electrical Engineering and Communication, Department of Power Electrical and Electronic Engineering, Brno University of Technology, Brno, Czech Republic
- 700 1_
- $a Bernard, V $u Faculty of Medicine, Department of Biophysics, Masaryk University, Brno, Czech Republic
- 700 1_
- $a Válek, Vlastimil, $u Department of Radiology and Nuclear Medicine, University Hospital Brno and Masaryk University Brno, Brno, Czech Republic $d 1960- $7 nlk20010098982
- 700 1_
- $a Goldberg, S Nahum $u Medical Center, Hadassah Hebrew University, Jerusalem, Israel
- 773 0_
- $w MED00002331 $t International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group $x 1464-5157 $g Roč. 38, č. 1 (2021), s. 393-401
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/33682581 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20211013 $b ABA008
- 991 __
- $a 20211116135855 $b ABA008
- 999 __
- $a ok $b bmc $g 1715077 $s 1146758
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2021 $b 38 $c 1 $d 393-401 $e - $i 1464-5157 $m International journal of hyperthermia $n Int J Hyperthermia $x MED00002331
- LZP __
- $a Pubmed-20211013