- kazuistiky MeSH
Introduction: Reports on the use of computer-assisted trauma surgery of comminuted scapula fracture are still quite rare. In this article, we present a case of comminuted scapula fracture, the surgical reconstruction of which was pre-operatively planned using a complex software solution. Materials and methods: For surgical planning of the fracture, we used the TraumaTech software facilitating virtual reconstruction (both manual and automatic), surgery planning, design of the implant, planning of screw placement and lengths, and production of a 3D print model of the fracture and the implant. The software also supported ordering such custom-made plate from a plate producer who was capable of fast and precise production of the plate. Results: The surgery using the custom-ordered plate was successful. The actual used screw lengths did not differ from the planned ones by more than 2 mm. One year after the surgery, the patient was capable of more demanding activities and doing sports activities. Conclusion: This approach provides a great way to prevent complications of the surgery and to shorten its duration. To the best of our knowledge, this is the first description of the treatment of a scapula comminuted fracture utilizing computer-assisted preoperative planning.
IT4Innovations Centre of Excellence Brno University of Technology Brno 708 00 Czech Republic
Trauma Center University Hospital Ostrava 17 listopadu 1790 5 Ostrava 708 52 Czech Republic
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22001470
- 003
- CZ-PrNML
- 005
- 20230516145941.0
- 007
- ta
- 008
- 220107s2021 pl f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1515/med-2021-0338 $2 doi
- 035 __
- $a (PubMed)34722895
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a pl
- 100 1_
- $a Madeja, Roman $u Institute of Emergency Medicine, Faculty of Medicine, University of Ostrava, Ostrava 703 00, Czech Republic $u Trauma Center, University Hospital Ostrava, 17. listopadu 1790/5, Ostrava 708 52, Czech Republic
- 245 10
- $a Computer-assisted preoperative planning of reduction of and osteosynthesis of scapular fracture: A case report / $c R. Madeja, G. Bajor, O. Klima, L. Bialy, J. Pometlova
- 520 9_
- $a Introduction: Reports on the use of computer-assisted trauma surgery of comminuted scapula fracture are still quite rare. In this article, we present a case of comminuted scapula fracture, the surgical reconstruction of which was pre-operatively planned using a complex software solution. Materials and methods: For surgical planning of the fracture, we used the TraumaTech software facilitating virtual reconstruction (both manual and automatic), surgery planning, design of the implant, planning of screw placement and lengths, and production of a 3D print model of the fracture and the implant. The software also supported ordering such custom-made plate from a plate producer who was capable of fast and precise production of the plate. Results: The surgery using the custom-ordered plate was successful. The actual used screw lengths did not differ from the planned ones by more than 2 mm. One year after the surgery, the patient was capable of more demanding activities and doing sports activities. Conclusion: This approach provides a great way to prevent complications of the surgery and to shorten its duration. To the best of our knowledge, this is the first description of the treatment of a scapula comminuted fracture utilizing computer-assisted preoperative planning.
- 655 _2
- $a kazuistiky $7 D002363
- 700 1_
- $a Bajor, Grzegorz $u Department of Human Anatomy, Faculty of Medical Science in Katowice, Medical University in Katowice, Katowice 40-752, Poland
- 700 1_
- $a Klima, Ondrej $u IT4Innovations Centre of Excellence, Brno University of Technology, Brno 708 00, Czech Republic
- 700 1_
- $a Bialy, Lubor $u Institute of Emergency Medicine, Faculty of Medicine, University of Ostrava, Ostrava 703 00, Czech Republic $u Trauma Center, University Hospital Ostrava, 17. listopadu 1790/5, Ostrava 708 52, Czech Republic
- 700 1_
- $a Pometlová, Jana $u Trauma Center, University Hospital Ostrava, 17. listopadu 1790/5, Ostrava 708 52, Czech Republic $u Department of Medicine of Disasters, Faculty of Medicine, University of Ostrava, Ostrava 703 00, Czech Republic $7 xx0301648
- 773 0_
- $w MED00196573 $t Open medicine $x 2391-5463 $g Roč. 16, č. 1 (2021), s. 1597-1601
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/34722895 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20220107 $b ABA008
- 991 __
- $a 20230516145938 $b ABA008
- 999 __
- $a ind $b bmc $g 1745492 $s 1152617
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2021 $b 16 $c 1 $d 1597-1601 $e 20211025 $i 2391-5463 $m Open medicine $n Open Med (Wars) $x MED00196573
- LZP __
- $a Pubmed-20220107