• Je něco špatně v tomto záznamu ?

Monolayer PC3: A promising material for environmentally toxic nitrogen-containing multi gases

K. Rajput, J. He, T. Frauenheim, DR. Roy

. 2022 ; 422 (-) : 126761. [pub] 20210728

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc22002966

Carbon and its analogous nanomaterials are beneficial for toxic gas sensors since they are used to increase the electrochemically active surface region and improve the transmission of electrons. The present article addresses a detailed investigation on the potential of the monolayer PC3 compound as a possible sensor material for environmentally toxic nitrogen-containing gases (NCGs), namely NH3, NO, and NO2. The entire work is carried out under the frameworks of density functional theory, ab-initio molecular dynamics simulations, and non-equilibrium Green's function approaches. The monolayer-gas interactions are studied with the van der Waals dispersion correction. The stability of pristine monolayer PC3 is confirmed through dynamical, mechanical, and thermal analyses. The mobility and relaxation time of 2D PC3 sensor material with NCGs are obtained in the range of 101-104 cm2 V-1 s-1 and 101-103 fs for armchair and zigzag directions, respectively. Out of six possible adsorption sites for toxic gases on the PC3 surface, the most prominent site is identified with the highest adsorption energy for all the NCGs. Considering the most stable configuration site of the NCGs, we have obtained relevant electronic properties by utilizing the band unfolding technique. The considerable adsorption energies are obtained for NO and NO2 compared to NH3. Although physisorption is observed for all the NCGs on the PC3 surface, NO2 is found to convert into NO and O at 5.05 ps (at 300 K) under molecular dynamics simulation. The maximum charge transfer (0.31e) and work function (5.17 eV) are observed for the NO2 gas molecule in the series. Along with the considerable adsorption energies for NO and NO2 gas molecules, their shorter recovery time (0.071 s and 0.037 s, respectively) from the PC3 surface also identifies 2D PC3 as a promising sensor material for those environmentally toxic gases. The experimental viability and actual implications for PC3 monolayer as NCGs sensor material are also confirmed by examining the humidity effect and transport properties with modeled sensor devices. The transport properties (I-V characteristics) reflect the significant sensitivity of PC3 monolayer toward NO and NO2 molecules. These results certainly confirm PC3 monolayer as a promising sensor material for NO and NO2 NCG molecules.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22002966
003      
CZ-PrNML
005      
20220127150751.0
007      
ta
008      
220113s2022 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.jhazmat.2021.126761 $2 doi
035    __
$a (PubMed)34418836
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Rajput, Kaptan $u Materials and Biophysics Group, Department of Applied Physics, Sardar Vallabhbhai National Institute of Technology, Surat, India
245    10
$a Monolayer PC3: A promising material for environmentally toxic nitrogen-containing multi gases / $c K. Rajput, J. He, T. Frauenheim, DR. Roy
520    9_
$a Carbon and its analogous nanomaterials are beneficial for toxic gas sensors since they are used to increase the electrochemically active surface region and improve the transmission of electrons. The present article addresses a detailed investigation on the potential of the monolayer PC3 compound as a possible sensor material for environmentally toxic nitrogen-containing gases (NCGs), namely NH3, NO, and NO2. The entire work is carried out under the frameworks of density functional theory, ab-initio molecular dynamics simulations, and non-equilibrium Green's function approaches. The monolayer-gas interactions are studied with the van der Waals dispersion correction. The stability of pristine monolayer PC3 is confirmed through dynamical, mechanical, and thermal analyses. The mobility and relaxation time of 2D PC3 sensor material with NCGs are obtained in the range of 101-104 cm2 V-1 s-1 and 101-103 fs for armchair and zigzag directions, respectively. Out of six possible adsorption sites for toxic gases on the PC3 surface, the most prominent site is identified with the highest adsorption energy for all the NCGs. Considering the most stable configuration site of the NCGs, we have obtained relevant electronic properties by utilizing the band unfolding technique. The considerable adsorption energies are obtained for NO and NO2 compared to NH3. Although physisorption is observed for all the NCGs on the PC3 surface, NO2 is found to convert into NO and O at 5.05 ps (at 300 K) under molecular dynamics simulation. The maximum charge transfer (0.31e) and work function (5.17 eV) are observed for the NO2 gas molecule in the series. Along with the considerable adsorption energies for NO and NO2 gas molecules, their shorter recovery time (0.071 s and 0.037 s, respectively) from the PC3 surface also identifies 2D PC3 as a promising sensor material for those environmentally toxic gases. The experimental viability and actual implications for PC3 monolayer as NCGs sensor material are also confirmed by examining the humidity effect and transport properties with modeled sensor devices. The transport properties (I-V characteristics) reflect the significant sensitivity of PC3 monolayer toward NO and NO2 molecules. These results certainly confirm PC3 monolayer as a promising sensor material for NO and NO2 NCG molecules.
650    _2
$a adsorpce $7 D000327
650    _2
$a elektrony $7 D004583
650    12
$a plyny $7 D005740
650    12
$a nanostruktury $7 D049329
650    _2
$a dusík $7 D009584
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a He, Junjie $u Bremen Center for Computational Materials Science, University of Bremen, 28359 Bremen, Germany; Department of Physical and Macromolecular Chemistry & Charles University Centre of Advanced Materials, Faculty of Science, Charles University in Prague, Hlavova 8, Prague 2 128 43, Czech Republic
700    1_
$a Frauenheim, Thomas $u Bremen Center for Computational Materials Science, University of Bremen, 28359 Bremen, Germany; Computational Science Research Center (CSRC) Beijing and Computational Science and Applied Research (CSAR) Institute, Shenzhen, Beijing 100193, China. Electronic address: thomas.frauenheim@bccms.uni-bremen.de
700    1_
$a Roy, Debesh R $u Materials and Biophysics Group, Department of Applied Physics, Sardar Vallabhbhai National Institute of Technology, Surat, India; Bremen Center for Computational Materials Science, University of Bremen, 28359 Bremen, Germany; Hanse-Wissenschaftskolleg (HWK), Lehmkuhlenbusch 4, 27753 Delmenhorst, Germany. Electronic address: drr@phy.svnit.ac.in
773    0_
$w MED00180297 $t Journal of hazardous materials $x 1873-3336 $g Roč. 422, č. - (2022), s. 126761
856    41
$u https://pubmed.ncbi.nlm.nih.gov/34418836 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20220113 $b ABA008
991    __
$a 20220127150747 $b ABA008
999    __
$a ok $b bmc $g 1750682 $s 1154115
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2022 $b 422 $c - $d 126761 $e 20210728 $i 1873-3336 $m Journal of hazardous materials $n J Hazard Mater $x MED00180297
LZP    __
$a Pubmed-20220113

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...