Admin or Manager login required
Admin or Manager login required
Admin or Manager login required
Admin or Manager login required
Admin or Manager login required
Admin or Manager login required
Detail
Article
Online article
FT
Medvik - BMC
  • Something wrong with this record ?

Unattended automated office blood pressure measurement in children

T. Seeman, K. Staněk, J. Slížek, J. Filipovský, J. Feber

. 2021 ; 30 (6) : 359-366. [pub] 20210925

Language English Country Great Britain

Document type Journal Article

PURPOSE: We studied the performance of unattended automated office blood pressure (uAOBP) measurement in children, in relation to oscillometric office BP (OBP) and ambulatory blood pressure monitoring (ABPM). MATERIALS AND METHODS: One hundred and eleven stable treated and untreated outpatients investigated for hypertension underwent uAOBP measurements (seated unattended in a quiet room separate from the renal clinic room, six times after a 5 min rest with the BpTRU device), and immediately before using the oscillometric device. Ambulatory 24 h blood pressure monitoring (ABPM) was performed on the same day in a subgroup of 42 children. RESULTS: UAOBP measurements were successful in 106 children (95%), 5 pre-school children did not tolerate to be alone in the room. The mean ± SD systolic/diastolic uAOBP, OBP and daytime ABP were 109.1 ± 14.0/70.8 ± 10.7 mmHg, 121.6 ± 16.5/77.6 ± 10.5 mmHg and 123.5 ± 11.3/73.7 ± 6.8 mmHg, respectively. Systolic/diastolic uAOBP was significantly lower than OBP by 13.6/7.6 mmHg (p < 0.0001) and lower than daytime ABP by 14.4 ± 0.5/2.9 ± 0.3 mmHg (p < 0.0001). The heart rate was not significantly different during uAOBP than during OBP measurements. On Bland Altman analysis the uAOBP underestimated OBP by a mean of 15.6 mmHg for systolic BP and by 8.6 mmHg for diastolic BP. In all 9 children with white-coat systolic hypertension uAOBP was within the normal range (<95th pc for OBP), in six of nine children with white-coat diastolic hypertension uAOBP was within the normal range however, in three of them it was elevated despite normal ABP. CONCLUSION: uAOBP measurement is feasible in school-aged children, its values are considerably lower than OBP as well as daytime ABP and it could help with detection of white-coat systolic hypertension. The clinical applicability of uAOBP in children should be confirmed in further studies.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22003059
003      
CZ-PrNML
005      
20231005102738.0
007      
ta
008      
220113s2021 xxk f 000 0|eng||
009      
AR
024    7_
$a 10.1080/08037051.2021.1963666 $2 doi
035    __
$a (PubMed)34565278
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Seeman, Tomáš $u Department of Pediatrics, Charles University Prague, 2nd Faculty of Medicine, Prague, Czech Republic
245    10
$a Unattended automated office blood pressure measurement in children / $c T. Seeman, K. Staněk, J. Slížek, J. Filipovský, J. Feber
520    9_
$a PURPOSE: We studied the performance of unattended automated office blood pressure (uAOBP) measurement in children, in relation to oscillometric office BP (OBP) and ambulatory blood pressure monitoring (ABPM). MATERIALS AND METHODS: One hundred and eleven stable treated and untreated outpatients investigated for hypertension underwent uAOBP measurements (seated unattended in a quiet room separate from the renal clinic room, six times after a 5 min rest with the BpTRU device), and immediately before using the oscillometric device. Ambulatory 24 h blood pressure monitoring (ABPM) was performed on the same day in a subgroup of 42 children. RESULTS: UAOBP measurements were successful in 106 children (95%), 5 pre-school children did not tolerate to be alone in the room. The mean ± SD systolic/diastolic uAOBP, OBP and daytime ABP were 109.1 ± 14.0/70.8 ± 10.7 mmHg, 121.6 ± 16.5/77.6 ± 10.5 mmHg and 123.5 ± 11.3/73.7 ± 6.8 mmHg, respectively. Systolic/diastolic uAOBP was significantly lower than OBP by 13.6/7.6 mmHg (p < 0.0001) and lower than daytime ABP by 14.4 ± 0.5/2.9 ± 0.3 mmHg (p < 0.0001). The heart rate was not significantly different during uAOBP than during OBP measurements. On Bland Altman analysis the uAOBP underestimated OBP by a mean of 15.6 mmHg for systolic BP and by 8.6 mmHg for diastolic BP. In all 9 children with white-coat systolic hypertension uAOBP was within the normal range (<95th pc for OBP), in six of nine children with white-coat diastolic hypertension uAOBP was within the normal range however, in three of them it was elevated despite normal ABP. CONCLUSION: uAOBP measurement is feasible in school-aged children, its values are considerably lower than OBP as well as daytime ABP and it could help with detection of white-coat systolic hypertension. The clinical applicability of uAOBP in children should be confirmed in further studies.
650    _2
$a krevní tlak $7 D001794
650    _2
$a měření krevního tlaku $7 D001795
650    _2
$a ambulantní monitorování krevního tlaku $7 D018660
650    _2
$a dítě $7 D002648
650    _2
$a předškolní dítě $7 D002675
650    _2
$a lidé $7 D006801
650    12
$a hypertenze $x diagnóza $7 D006973
650    12
$a syndrom bílého pláště $x diagnóza $7 D059466
655    _2
$a časopisecké články $7 D016428
700    1_
$a Staněk, Kryštof $u 2nd Faculty of Medicine, Univerzita Karlova, Praha, Czech Republic $7 xx0307909
700    1_
$a Slížek, Jakub $u 2nd Faculty of Medicine, Univerzita Karlova, Praha, Czech Republic
700    1_
$a Filipovský, Jan $u Department of Internal Medicine II, Univerzita Karlova, Praha, Czech Republic
700    1_
$a Feber, Janusz $u Department of Pediatrics, University of Ottawa, Ottawa, Canada
773    0_
$w MED00000810 $t Blood pressure $x 1651-1999 $g Roč. 30, č. 6 (2021), s. 359-366
856    41
$u https://pubmed.ncbi.nlm.nih.gov/34565278 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20220113 $b ABA008
991    __
$a 20231005102733 $b ABA008
999    __
$a ok $b bmc $g 1750740 $s 1154208
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 30 $c 6 $d 359-366 $e 20210925 $i 1651-1999 $m Blood pressure $n Blood Press $x MED00000810
LZP    __
$a Pubmed-20220113

Find record

Citation metrics

Logged in users only

Archiving options

Loading data ...