Affiblot: a dot blot-based screening device for selection of reliable antibodies

Z. Svobodova, J. Novotny, B. Ospalkova, M. Slovakova, Z. Bilkova, F. Foret

. 2021 ; 13 (35) : 3874-3884. [pub] 20210916

Jazyk angličtina Země Velká Británie

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc22003715

The key factor in the development of antibody-based assays is to find an antibody that has an appropriate affinity, high specificity, and low cross-reactivity. However, this task is not easy to carry out since the research antibodies on the market may suffer from low specificity and reproducibility. Here, we report on a palm-sized dot blot-based device, called the affiblot, that has a specially designed lid that allows simultaneous semi-quantitative comparison of up to five antibodies from different suppliers regarding their affinity/avidity, cross-reactivity, and batch-to-batch reliability. The only required peripheral equipment is a vacuum pump, a camera, and densitometry software. The affiblot device was tested for its functionality and its measurements were compared against those obtained by standard dot blot and ELISA. The benefit over these methods, when various antibodies are evaluated, is in its simplicity. It allows easy antigen deposition, fast application and the discarding of the solutions, a compact undivided membrane, and therefore significant decrease of labor. The device was tested with specific anti-ApoE, anti-EpCAM, anti-Salmonella, anti-E. coli, and anti-Listeria antibodies from different suppliers. Their properties were compared for their ability to interact specifically with antigen and/or non-target structures and the best-suited antibody for the intended application was identified.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22003715
003      
CZ-PrNML
005      
20220127145942.0
007      
ta
008      
220113s2021 xxk f 000 0|eng||
009      
AR
024    7_
$a 10.1039/d1ay00955a $2 doi
035    __
$a (PubMed)34528947
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Svobodova, Zuzana $u Department of Biological and Biochemical Sciences, Faculty of Chemical Technology, University of Pardubice, Studentska 573, Pardubice, Czech Republic. svobozu@faf.cuni.cz $u Department of Biological and Medical Sciences, Faculty of Pharmacy in Hradec Kralove, Charles University, Zborovska 2089, Czech Republic
245    10
$a Affiblot: a dot blot-based screening device for selection of reliable antibodies / $c Z. Svobodova, J. Novotny, B. Ospalkova, M. Slovakova, Z. Bilkova, F. Foret
520    9_
$a The key factor in the development of antibody-based assays is to find an antibody that has an appropriate affinity, high specificity, and low cross-reactivity. However, this task is not easy to carry out since the research antibodies on the market may suffer from low specificity and reproducibility. Here, we report on a palm-sized dot blot-based device, called the affiblot, that has a specially designed lid that allows simultaneous semi-quantitative comparison of up to five antibodies from different suppliers regarding their affinity/avidity, cross-reactivity, and batch-to-batch reliability. The only required peripheral equipment is a vacuum pump, a camera, and densitometry software. The affiblot device was tested for its functionality and its measurements were compared against those obtained by standard dot blot and ELISA. The benefit over these methods, when various antibodies are evaluated, is in its simplicity. It allows easy antigen deposition, fast application and the discarding of the solutions, a compact undivided membrane, and therefore significant decrease of labor. The device was tested with specific anti-ApoE, anti-EpCAM, anti-Salmonella, anti-E. coli, and anti-Listeria antibodies from different suppliers. Their properties were compared for their ability to interact specifically with antigen and/or non-target structures and the best-suited antibody for the intended application was identified.
650    12
$a monoklonální protilátky $7 D000911
650    _2
$a zkřížené reakce $7 D003429
650    _2
$a ELISA $7 D004797
650    _2
$a imunoblotting $7 D015151
650    _2
$a reprodukovatelnost výsledků $7 D015203
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Novotny, Jakub $u Department of Biological and Biochemical Sciences, Faculty of Chemical Technology, University of Pardubice, Studentska 573, Pardubice, Czech Republic. svobozu@faf.cuni.cz $u Institute of Analytical Chemistry of the CAS, v. v. i., Veveri 967/97, Brno, Czech Republic
700    1_
$a Ospalkova, Barbora $u Department of Biological and Biochemical Sciences, Faculty of Chemical Technology, University of Pardubice, Studentska 573, Pardubice, Czech Republic. svobozu@faf.cuni.cz
700    1_
$a Slovakova, Marcela $u Department of Biological and Biochemical Sciences, Faculty of Chemical Technology, University of Pardubice, Studentska 573, Pardubice, Czech Republic. svobozu@faf.cuni.cz
700    1_
$a Bilkova, Zuzana $u Department of Biological and Biochemical Sciences, Faculty of Chemical Technology, University of Pardubice, Studentska 573, Pardubice, Czech Republic. svobozu@faf.cuni.cz
700    1_
$a Foret, Frantisek $u Institute of Analytical Chemistry of the CAS, v. v. i., Veveri 967/97, Brno, Czech Republic
773    0_
$w MED00208691 $t Analytical methods : advancing methods and applications $x 1759-9679 $g Roč. 13, č. 35 (2021), s. 3874-3884
856    41
$u https://pubmed.ncbi.nlm.nih.gov/34528947 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20220113 $b ABA008
991    __
$a 20220127145938 $b ABA008
999    __
$a ok $b bmc $g 1751234 $s 1154864
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 13 $c 35 $d 3874-3884 $e 20210916 $i 1759-9679 $m Analytical methods $n Anal Methods $x MED00208691
LZP    __
$a Pubmed-20220113

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...