Characterization of various geometric arrangements of "air-assisted" flow gating interfaces for capillary electrophoresis

F. Opekar, P. Tůma

. 2021 ; 42 (6) : 749-755. [pub] 20201203

Jazyk angličtina Země Německo

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc22004573

For connecting flow-through analytical methods with capillary electrophoresis, a chip working in the air-assisted flow gating interface regime is cast from poly(dimethylsiloxane). In the injection space, the exit from the delivery capillary is placed close to the entrance to the separation capillary. Prior to injecting the sample into the separation capillary, the background electrolyte is forced out of the injection space by a stream of air. In the empty space, a drop of the sample with a volume of <100 nL is formed between the exit from the delivery capillary and the entrance into the separation capillary, from which the sample is injected hydrodynamically into the separation capillary. After injection, the injection space is filled with BGE, and the separation can be begun. Three geometric variants for the mutual geometric arrangement of the delivery and separation capillaries were tested: the delivery capillary is placed perpendicular to the separation capillary, from either above or below, or the capillaries are placed axially, that is, directly opposite one another. All of the variants are equivalent from the analytical and separation efficiency viewpoints. The repeatability expressed by RSD is up to 5%. The tested flow gating interface variants are also suitable for continuous and discontinuous sampling at flow rates of the order of units of μL/min. The developed instrument for sequential electrophoretic analysis operates fully automatically and is suitable for rapid sequential monitoring of dynamic processes.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22004573
003      
CZ-PrNML
005      
20220127145140.0
007      
ta
008      
220113s2021 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1002/elps.202000305 $2 doi
035    __
$a (PubMed)33191565
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Opekar, František $u Faculty of Science, Department of Analytical Chemistry, Charles University, Prague, Czechia
245    10
$a Characterization of various geometric arrangements of "air-assisted" flow gating interfaces for capillary electrophoresis / $c F. Opekar, P. Tůma
520    9_
$a For connecting flow-through analytical methods with capillary electrophoresis, a chip working in the air-assisted flow gating interface regime is cast from poly(dimethylsiloxane). In the injection space, the exit from the delivery capillary is placed close to the entrance to the separation capillary. Prior to injecting the sample into the separation capillary, the background electrolyte is forced out of the injection space by a stream of air. In the empty space, a drop of the sample with a volume of <100 nL is formed between the exit from the delivery capillary and the entrance into the separation capillary, from which the sample is injected hydrodynamically into the separation capillary. After injection, the injection space is filled with BGE, and the separation can be begun. Three geometric variants for the mutual geometric arrangement of the delivery and separation capillaries were tested: the delivery capillary is placed perpendicular to the separation capillary, from either above or below, or the capillaries are placed axially, that is, directly opposite one another. All of the variants are equivalent from the analytical and separation efficiency viewpoints. The repeatability expressed by RSD is up to 5%. The tested flow gating interface variants are also suitable for continuous and discontinuous sampling at flow rates of the order of units of μL/min. The developed instrument for sequential electrophoretic analysis operates fully automatically and is suitable for rapid sequential monitoring of dynamic processes.
650    _2
$a elektrolyty $7 D004573
650    12
$a elektroforéza kapilární $7 D019075
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Tůma, Petr $u Department of Hygiene, Third Faculty of Medicine, Charles University, Prague, Czechia
773    0_
$w MED00001508 $t Electrophoresis $x 1522-2683 $g Roč. 42, č. 6 (2021), s. 749-755
856    41
$u https://pubmed.ncbi.nlm.nih.gov/33191565 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20220113 $b ABA008
991    __
$a 20220127145136 $b ABA008
999    __
$a ok $b bmc $g 1751889 $s 1155722
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 42 $c 6 $d 749-755 $e 20201203 $i 1522-2683 $m Electrophoresis $n Electrophoresis $x MED00001508
LZP    __
$a Pubmed-20220113

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...